A sanitary heat exchanger transfers heat between a process fluid and a heating or cooling medium without the two streams contacting each other — heating, cooling, or holding product streams at temperature in pharmaceutical, biotech, cosmetic, and food & beverage manufacturing. The common designs are shell-and-tube, plate, and tube-in-tube (including double-tubesheet units for WFI), each chosen for its cleanability and the degree of stream separation it provides. Paul Industries installs, ties in, services, and repairs sanitary and industrial heat exchangers for facilities across the United States, with more than 30 years of cGMP/FDA-compliant experience.
Request a Project Quote or call 201-450-8280
How a sanitary heat exchanger works
A heat exchanger moves thermal energy from one fluid to another across a solid barrier — tube walls or plates — so the two streams never mix. In a sanitary application, one side carries the product or a high-purity utility (WFI, purified water, a process stream), while the other carries the service medium (plant steam, hot water, chilled water, or glycol). The barrier is designed and finished so the product-contact surface is smooth, drainable, and cleanable, keeping the exchanger compatible with CIP/SIP and free of the crevices and dead legs where product could stagnate.
Sanitary construction differs from ordinary industrial construction in materials, surface finish, and geometry: 316L stainless product-contact surfaces, controlled internal finish, hygienic connections, and self-draining orientation. Where a product stream must be protected from any possibility of utility ingress — for example a WFI or clean-steam service — a double-tubesheet design adds a vented space between the two fluids so a leak is detectable and cannot cross into the product. Paul Industries selects, installs, and ties these exchangers into existing process and utility piping, and services or replaces units already in the plant.
Heat exchanger types compared
The three most common sanitary configurations differ in how the streams are separated, how easily they are cleaned and inspected, and where they fit best. Most facilities use more than one type across their utilities.
| Shell-and-tube | Plate | Tube-in-tube | |
|---|---|---|---|
| Typical application | General heating/cooling, high pressure/temperature | Compact duties, tight temperature approach | Viscous or particulate product streams, WFI service |
| Sanitary fit | Good; excellent as double-tubesheet | Good with hygienic gasketed/welded plates | Excellent; crevice-free, fully drainable |
| Stream separation | High (single or double tubesheet) | Moderate (thin plate barrier) | Highest; single continuous barrier |
| Maintenance | Cleanable in place; tubes inspectable | Gasketed units open for service | Low; minimal internal surfaces |
| Footprint | Larger | Compact / high-density | Linear; can be long |
Brazed, plastic and kettle-type heat exchangers
A brazed heat exchanger is a stack of stainless plates joined in a vacuum furnace with copper or nickel filler, with no gaskets and no frame, which makes it compact and tight but impossible to open. Cleaning is by circulating chemical solution through the pack, so these units belong on clean utility duties: chilled water, glycol, refrigerant and closed loops. Copper-brazed units are ruled out for ammonia, which attacks copper, and take nickel filler instead. Published temperature limits for copper-brazed units run from about 185 C to 225 C depending on the maker, and each manufacturer states its own pressure limit. Sanitary product duties stay with gasketed plate or tube designs that can be inspected.
A plastic heat exchanger suits fluids that would corrode metal, such as hot acids and high-chloride streams, using materials like PTFE, PVDF or polypropylene. Plastic heat exchangers conduct heat far less well than metal, so they need more surface area for a given duty, and their pressure and temperature limits are lower. Selection starts from the chemical resistance chart of the plastic at the operating temperature.
| Design | Construction | Where it fits | Point to check |
|---|---|---|---|
| Brazed plate | Sealed plate pack, copper or nickel brazed | Clean closed loops, refrigerant duties, tight footprints | Strainer upstream, because the pack cannot be opened |
| Plastic shell and tube or plate | PTFE, PVDF or polypropylene wetted parts | Corrosive streams | Rated pressure at the actual temperature |
| TEMA K shell kettle reboiler | Tube bundle in an enlarged shell with a vapor space above | Continuous column boil-up | Disengagement space, weir and level control |
| Jacketed kettle, sometimes listed as a jacketed kettle reboiler | Vessel heated through a steam or hot oil jacket | Batch stills and solvent recovery on small volumes | Jacket relief, condensate removal, limited heat transfer area |
Paul Industries sets and pipes all four, with strainers, isolation valves and test records to suit; our plate heat exchanger page goes deeper on framed units.
Our heat exchanger services
Paul Industries handles heat exchangers as a single-source scope so one team is accountable from selection through a running, tied-in unit — and stays available to service it afterward:
- Selection & sizing — matching exchanger type (shell-and-tube, plate, tube-in-tube, double-tubesheet) to your duty, fluids, pressure, temperature, and cleanability requirements.
- Installation — setting, supporting, and orienting the exchanger for drainability, access, and CIP/SIP compatibility, with the work carried on one schedule.
- Process & utility tie-in — connecting product, steam, hot-water, chilled-water, and glycol lines with sanitary, orbital-welded piping to ASME BPE.
- Service & repair — leak testing, re-gasketing plate units, re-rolling or plugging tubes, and restoring existing exchangers to service.
- Replacement — swapping failed or undersized units, including re-piping and re-tie-in with minimal disruption to production.
- Documentation — weld, material, and pressure-test records for cGMP traceability, plus validation when the exchanger is part of a qualified system.
Industries we serve
We install and service sanitary heat exchangers for pharmaceutical and biotech drug manufacturing (WFI heating and cooling, bioreactor temperature control, product cooling), cosmetic and personal-care blending and filling, nutraceutical production, and food & beverage plants where 3-A sanitary design and hygienic construction apply. Each application has different fluids, temperatures, and pressures, and we match the exchanger type and materials to the duty rather than forcing one design to fit every service.
Standards & compliance
- ASME BPE (Bioprocessing Equipment)
- Governs the hygienic design, materials, surface finish, and weld quality of the product-contact side of a sanitary heat exchanger — the basis for a cleanable, drainable unit that stays CIP/SIP-compatible.
- ASME Section VIII / TEMA
- ASME Boiler & Pressure Vessel Code Section VIII governs the pressure-retaining design of heat exchangers, while TEMA provides the mechanical standards for shell-and-tube construction, ratings, and tolerances.
- 3-A Sanitary Standards
- Sanitary design criteria widely applied in food, dairy, and beverage processing so heat-exchange equipment can be reliably cleaned and inspected.
- Double-tubesheet design (for WFI)
- A double-tubesheet exchanger places a vented gap between the product tubes and the service side so any leak weeps to atmosphere and is detectable — it cannot cross into the product. This is why it is specified for WFI and other services where utility ingress into the product stream is unacceptable.
- cGMP / 21 CFR 211
- FDA current Good Manufacturing Practice requirements that make a product-contact heat exchanger a validated, documented part of the process rather than a generic utility component.
Why Paul Industries
Because we own selection, sanitary-piping fabrication, installation, and tie-in — and return to service and repair what we install — a Paul Industries heat-exchanger project has a single point of accountability. There is no gap between the engineer who sizes the unit, the welder who pipes it in, and the crew that maintains it. Our teams have delivered process-equipment and high-purity systems across the United States for more than three decades, and every weld and pressure test is documented for cGMP traceability. We provide capability statements, weld, material, and test documentation on request, while keeping client project details confidential.
Standards referenced: ASME BPE · ASME Boiler and Pressure Vessel Code · 3-A Sanitary Standards · 21 CFR 211
Related: Dairy Plant Sanitary Piping and CIP Systems · Dairy Heat Exchangers and Pasteurizer Installation · Brewery Tanks, Glycol Systems and Wort Cooling · Meat and Poultry Plant Utilities and Process Piping · Cosmetic Emulsion Mixing Tanks and CIP Systems · Food and Beverage Heat Exchangers and Pasteurizers · Data Center Water Treatment, Cooling Loops and Process Piping · Oil and Gas Process Piping, Produced Water Treatment and Turnaround Support · Plate Heat Exchangers: Plate and Frame Installation, Cleaning, Gaskets and Repair · Chilled Water System Design, Installation and Service · Data Center Cooling Systems: Design, Installation and Service · Steam Trap Types, Testing, Surveys, Repair and Replacement · Data Center Liquid Cooling: CDUs, Cold Plates, Rear Doors and TCS Piping · Dry Cooler Guide: How Dry and Adiabatic Coolers Work, Compare and Are Maintained · Server Immersion Cooling: Tanks, Piping and Facility Water for Data Centers · Heat Exchanger Repair, Cleaning and Maintenance · Shell and Tube Heat Exchanger: Parts, TEMA Types, Design and Sizing
Repair vs replace on a leaking sanitary exchanger
A leak gets diagnosed before it gets priced, because the two routes diverge at the failure mode. On a plate unit, weeping between plates is usually the gasket, and the answer is opening the pack, re-gasketing, closing to the recorded tightening dimension and holding pressure before release. A cracked or eroded plate is a different matter: plates have to be replaced in kind, and a pack assembled from mixed plate patterns no longer has the channel geometry the thermal datasheet was built on.
On shell-and-tube, a failed tube can be plugged. That buys an immediate return to service and costs heat transfer area, which is a reasonable trade once and a poor habit repeated, because duty falls with every plug until the unit no longer holds the process. Re-tubing restores the area and takes the outage that plugging avoided. The key question at that point is whether the unit was correctly sized for current production in the first place.
Double-tubesheet construction changes the calculation on high-purity duty. The vented interspace shows which side gave way and keeps a utility stream out of product water, so a failure there is detected and contained rather than discovered in a sample result. Age of the elastomers, whether plates are still available for the model, and whether the exchanger still matches the load usually settle it. Re-gasketing a sound unit is quick and cheap. Rebuilding one that was marginal when it was installed is paying twice for the same limitation.
The operating costs that outlast the purchase price
Selection decisions that look like small premiums at the order stage set the running cost for the life of the unit. These are the ones that keep returning.
| Driver | How it shows up in service | What reduces it |
|---|---|---|
| Gasket life | Every re-gasket is an outage, a set of elastomers and a pressure hold before the quality unit will release the unit | Compound selected against the sanitization temperature rather than the process temperature |
| Fouling | Approach temperature drifts and utility flow climbs to hold the same setpoint | A stated fouling allowance in the datasheet, and cleaning velocity confirmed at design |
| Cleaning time | A unit that cannot be cleaned in place takes changeover hours out of every campaign | Drainable installed orientation and CIP compatibility verified before purchase |
| Tube plugging | Each plug removes area, so duty decays until the exchanger stops meeting the process | Surplus area carried at selection, plus control of the water chemistry causing the failures |
| Leak exposure | A single-wall failure on high-purity duty becomes a water quality investigation, not just a repair | Double-tubesheet construction with a vented interspace on WFI and product service |
| Removal access | A bundle that cannot be withdrawn in place turns a tube job into a rigging job | Withdrawal envelope checked against the room on the arrangement drawing |
What to require on a sanitary exchanger purchase and tie-in
Exchangers are frequently bought on a thermal duty and a price, and then fail on cleanability or access. The specification below covers both halves.
- ASME Section VIII documentation with nameplate data and the National Board registration number where the code applies, filed with the equipment record.
- The TEMA type designation stated, together with the thermal datasheet and the fouling factor actually used in the selection.
- Product-side finish expressed as an ASME BPE surface designation, with a measured roughness range on the certificate instead of a catalogue statement.
- Double-tubesheet construction with a vented and monitored interspace wherever purified water, WFI or product sits opposite a plant utility.
- Drainability proven in the installed orientation, with the low point and the fall shown on the arrangement drawing rather than assumed from the catalogue picture.
- Gasket specification naming the compound, its USP Class VI status and its continuous temperature rating checked against the steam cycle, not the product temperature.
- Cleanability expressed as a flow or velocity per channel or per tube, so the commissioning team can verify it with an instrument.
- Pressure test records for shell side and tube side separately, and a documented hold test after every re-gasket during the unit’s life.
- Material certificates for tube, plate and shell identifying the heat, retained in the turnover file.
- Passivation of the sanitary connections cut during the tie-in, certified per line, with the cleaning step preceding it recorded.
Heat exchanger name plate: what it tells you and how to read it
A heat exchanger name plate is the permanent record of how the unit was built and rated, showing at minimum the manufacturer, serial number, year built, maximum allowable working pressure and minimum design metal temperature on an ASME-stamped vessel. It is the first thing to photograph before any repair, re-tube, replacement or change of service.
| Marking | What it tells you |
|---|---|
| Certification mark with U designator | Built and inspected under ASME Section VIII Division 1 |
| MAWP at temperature, by chamber | The rating of shell side and tube side, which often differ |
| MDMT | The lowest metal temperature the rating holds at |
| Serial number and National Board number | The key to retrieving the manufacturer's data report for the unit |
| RT marks | Extent of radiography on the vessel |
| TEMA size and type, where ordered to TEMA | Shell diameter, tube length and the construction letters |
An alteration or re-rating under the National Board Inspection Code adds its own nameplate or stamping next to the original, with its location recorded on the Form R-2, so read both before relying on a rating. Insulation should be cut back around the plate, never over it. Paul’s heat exchanger repair work starts from these data, so replacement tubes and gaskets are ordered against the actual unit.
Reading a heat exchanger PID and each abbreviation
A heat exchanger PID (piping and instrumentation diagram) shows the unit as a symbol with an equipment tag, usually E-101 or HX-101, with each process line, valve and temperature or pressure instrument connected to the shell or tube side. Check the flow arrows on the symbol first, since they show which fluid is on which side. The heat exchanger abbreviation on the drawing usually identifies its type too.
| Abbreviation | Meaning |
|---|---|
| HX, HEX or E | Heat exchanger, in tags and line lists |
| STHE or S&T | Shell and tube heat exchanger |
| PHE and BPHE | Plate heat exchanger and brazed plate heat exchanger |
| BEM | TEMA fixed tubesheet with bonnet heads |
| AES | TEMA channel with a removable cover and a split-ring floating head |
| BEU | TEMA U-tube bundle with a bonnet head |
| LMTD | Log mean temperature difference, the driving figure in the thermal datasheet |
Frequently asked questions
What is a heat exchanger used for in process systems?
What is the difference between shell-and-tube and plate heat exchangers?
How does a shell-and-tube heat exchanger work?
What is a plate heat exchanger?
How do you size a heat exchanger?
What causes a heat exchanger to lose efficiency?
Fouling on one or both sides, and the two look identical on a temperature reading. Product-side fouling is deposit or protein build-up that a cleaning cycle is no longer clearing, often because the cycle was developed for a different soil. Service-side fouling is scale or biofilm in the cooling water or glycol circuit, which is a water treatment problem rather than a cleaning one. Trapped air on the service side and a partially blocked tube bundle produce the same symptom.
How are heat exchangers cleaned?
What is a tube-in-tube heat exchanger?
What materials are heat exchangers made from?
What is fouling and how is it controlled?
What is the difference between counterflow and parallel flow?
How do you install a heat exchanger in a process line?
When should a heat exchanger be repaired versus replaced?
What causes heat exchanger tubes to leak?
Do you provide heat exchangers nationwide?
Yes, and we fabricate the unit in house as well as handle specification, sanitary piping tie-ins, passivation of the installed assembly, insulation and qualification. That split is worth stating plainly in a quotation, since a contractor implying they fabricate pressure vessels when they procure them is telling you something about how the rest of the scope is described.
How do I select the right heat exchanger?
Start from the duty rather than the type: the fluids on both sides, flow rates, inlet and outlet temperatures, allowable pressure drop, and design pressure and temperature. Then the hygienic requirements: product contact finish, drainability, whether it will be cleaned in place or removed, and whether it must be steam sterilizable. Double tubesheet or double-wall construction is a fundamental configuration decision rather than an option, and it belongs in that first conversation.
Which heat exchanger type is right for my process?
What is a double-tubesheet exchanger and why is it used for WFI?
Do you service and repair existing heat exchangers?
What is the difference between sanitary and industrial construction?
Do you tie the exchanger into our process and utility piping?
Which states do you serve?
All 50 states, with Paul at your plant for planned and emergency work and dates confirmed at quotation. On heat exchanger scopes the binding constraint is normally unit lead time rather than crew scheduling. For attendance on a failed exchanger in a running plant, we commit a crew and confirm the arrival date at the first call, with same-day emergency response available in every state.
Get a heat exchanger project quote
Tell us about your duty, fluids, temperatures, and whether it is a new install, tie-in, or service/repair — a Paul Industries engineer will follow up to discuss scope, standards, and timeline.
Request a Project Quote or call 201-450-8280How do you choose a sanitary heat exchanger?
Choose on duty, cleanability and whether a leak could reach product — in that order. The thermal calculation is the easy part; the decisions that cause trouble later are hygienic design and how the unit is cleaned and inspected in service.
| Selection factor | What to establish | Why it decides the outcome |
|---|---|---|
| Duty at worst case | Heat load at peak flow and worst-case inlet temperatures | Sizing on nominal duty leaves no margin when the process runs hot |
| Exchanger type | Shell-and-tube, plate, tubular or scraped-surface | Plate units are compact and efficient; tubular is easier to clean and inspect and tolerates particulates |
| Product-contact leak path | What happens if the barrier fails | Where utility fluid could reach product, a double-tubesheet or double-wall design may be required |
| Cleanability | CIP-able in place, or must it be opened? | Plate packs that need opening add downtime and reassembly risk to every clean |
| Material | 316L product contact; gasket compatibility with product AND cleaning chemistry | Gasket selection fails on the CIP chemistry more often than on the product |
| Surface finish | Ra specified against the ASME BPE designation | Cannot be corrected after fabrication |
| Drainability | Fully drainable in the installed orientation | A unit that holds liquid is a growth site between runs |
| Inspection access | How internal condition is verified in service | Determines whether integrity testing is practical |
| Utility side | Clean steam, plant steam, chilled water or glycol | A jacket leak that could reach product is a clean steam duty regardless of the drawing |
What drives sanitary heat exchanger cost?
As with the rest of a process system, the exchanger is rarely the largest number once it is installed.
| Cost driver | What moves it | Where budgets go wrong |
|---|---|---|
| Type and surface area | Duty, approach temperature and fouling allowance | Approach temperature quietly drives area, and area drives price |
| Double-wall / double-tubesheet | Required where a leak must not reach product | Discovered at design review, after the budget is set |
| Material and finish | 316L, higher alloys, specified Ra, electropolish | Finish specified late and re-quoted |
| Gaskets and elastomers | Compatibility with product and CIP chemistry; USP Class VI where required | Chosen on temperature alone, then fail on chemistry |
| Installation and piping | Tie-ins, supports, insulation, instrumentation | Frequently exceeds the unit price in a retrofit |
| Utilities | Whether clean steam or chilled capacity already exists | The largest surprise — new utility generation is a project of its own |
| Controls integration | Temperature control loops tied into existing systems | Legacy integration effort underestimated |
| Passivation and documentation | Post-installation passivation and the turnover package | The line most often stripped from a low bid |
| Qualification | IQ/OQ | Omitted entirely from equipment-only quotes |
Paul Industries installs, pipes, passivates and supports qualification of sanitary heat exchangers nationwide, and prices the installed scope rather than the unit alone. Call 201-450-8280.
More questions we are asked
Heat exchanger symptoms and what they mean
| Symptom | Most likely cause | What to do |
|---|---|---|
| Approach temperature worsening over time | Fouling — product-side film or scale on the utility side | Clean; then ask why it fouled — velocity too low, or temperature too high at the wall |
| Sudden loss of duty | Air or gas binding, blocked passages, or a control valve not opening | Vent first — it is the cheapest check and often the answer |
| Product contamination with utility fluid | Barrier breach — a cracked plate, failed gasket or tube leak | Stop. This is a contamination event. Integrity-test before returning to service |
| Utility fluid contaminated with product | Same breach, opposite pressure differential | Same response — the direction only tells you which side was higher |
| Gasket leaking at the plate pack | Over- or under-tightened pack, wrong gasket, or thermal cycling | Torque to the manufacturer dimension, not to “tight” |
| Cannot achieve outlet temperature | Undersized for actual duty, fouling, or utility supply not at design temperature | Check the utility supply before condemning the exchanger |
| Excessive pressure drop | Fouling or partial blockage | Differential pressure trend tells you before duty loss does |
| Fails to drain | Orientation, or no drain point at the low side | A unit that holds liquid between runs is a growth site |
The one to treat as an emergency is barrier breach, because in a product-contact exchanger it is a contamination event rather than a maintenance item — and where a leak could put utility fluid into product, that utility should have been clean steam or compendial water in the first place.
What drives the cost of a sanitary heat exchanger installation?
Surface area driven by duty and approach temperature, whether double-wall or double-tubesheet construction is required, material and specified surface finish, gasket and elastomer selection, and then the installed scope: tie-in piping, supports, insulation, instrumentation, controls integration, post-installation passivation, documentation and qualification. The largest single surprise is utility generation, since an exchanger needing clean steam or chilled capacity that does not already exist adds a generation scope, which Paul builds alongside the exchanger.
When does a heat exchanger need double-wall or double-tubesheet construction?
When a failure of the barrier between the utility side and the product side would allow utility fluid to reach product. A single-wall unit carrying plant steam or untreated cooling water against product is a contamination path if the wall is breached, and the leak may not be immediately detectable. Double-tubesheet and double-wall designs provide a detectable interstitial space, and where a leak could reach product the utility itself may need to be clean steam or compendial water regardless of how the jacket is labelled on the drawing.
What causes a heat exchanger approach temperature to worsen?
Fouling, on either side. A product-side film or utility-side scale insulates the surface and degrades heat transfer gradually. Cleaning restores duty, but the more useful question is why it fouled: usually velocity too low to keep the surface swept, or wall temperature high enough to bake product onto it. Differential pressure trending will show fouling developing before the approach temperature does.
What should you do if a heat exchanger leaks between product and utility?
Treat it as a contamination event rather than a maintenance item. A cracked plate, failed gasket or tube leak breaches the barrier between utility fluid and product, and the pressure differential only determines which direction the contamination travelled. Take the unit out of service and integrity-test before returning it. Where a leak could put utility fluid into product, the utility itself should be clean steam or compendial water, and a double-tubesheet or double-wall design should have been specified.
Best sanitary heat exchangers for food and beverage processing
Plate heat exchangers dominate food and beverage because they give very high heat transfer in a small footprint, can be opened for inspection, and their capacity can be changed by adding or removing plates. Gasketed plate units suit most duties; where product viscosity or particulates are high, a scraped-surface or tubular unit is the better answer because plates blind. Tubular exchangers handle particulates and are easier to clean in place, at the cost of size. Triple-tube designs provide double separation between product and service fluid, which matters where cross-contamination would be serious. The controlling selection questions are particulate size, viscosity, fouling tendency and whether the unit must be openable for inspection.
What are the primary types of sanitary heat exchangers used in food processing?
Four types cover almost everything. Gasketed plate exchangers, the default for low-viscosity liquids, offering high efficiency and expandable capacity but with gaskets as a maintenance item and a leak path. Tubular and shell-and-tube designs, tolerant of particulates and pressure, easier to clean in place, larger for the same duty. Triple-tube designs, which put a service fluid on both sides of the product tube with a vented interstitial space so any leak is detected before fluids mix. And scraped-surface exchangers for viscous, sticky or crystallizing products where a rotating blade continuously clears the wall. Selection follows the product rather than the duty: viscosity and particulate size decide the type before heat load does.
How to choose a sanitary heat exchanger for pharmaceutical applications
Pharmaceutical selection is driven by cleanability and by what happens if the two fluids meet. Ask first whether a leak between service and product fluid is tolerable; where it is not, a double tube sheet or triple-tube arrangement with a monitored interstitial space is appropriate rather than a gasketed plate unit. Confirm the product side can be cleaned in place with demonstrated coverage and drains fully, because a unit that holds a heel cannot be validated. Specify surface finish to ASME BPE on product contact. Confirm materials, since 316L is standard but chloride-bearing service may need more. And confirm it can be sterilized if the process requires it, with condensate able to drain from every part.
How do I select the correct material for a pharmaceutical-grade heat exchanger?
316L is the default for product contact and is adequate for compendial water, most buffers and most product streams. The decision points that push beyond it are chlorides and temperature. Chloride-bearing solutions at elevated temperature will pit 316L, and the step up is a higher-molybdenum grade such as AL-6XN or 904L, then nickel alloys such as Hastelloy C-22 for genuinely aggressive chemistry. Titanium is used where chlorides are severe but reducing conditions are absent, commonly on seawater or brine duty. On the service side, materials can often be less expensive since only the product side needs hygienic specification. Gasket material matters as much as metal: EPDM for general and steam duty, PTFE-faced where solvents or oils are present.
Compare plate vs shell and tube sanitary heat exchangers
Plate units transfer heat far more efficiently per unit volume, so they are smaller and cheaper for the same duty, they can be opened for inspection and cleaning, and capacity is changed by adding plates. Their weaknesses are gaskets, which are a maintenance item and a potential leak path between fluids, intolerance of particulates which blind the narrow channels, and limited pressure and temperature range. Shell and tube units are larger and less efficient but handle particulates and viscous fluids, take higher pressures and temperatures, clean in place more readily, and with a double tube sheet give positive separation between fluids. For compendial water cooling after distillation, shell and tube with double tube sheet is the conventional choice for exactly that reason.
What if the heat exchanger name plate is missing or unreadable?
Start with the serial or National Board number on the drawings or the turnover file, then request the manufacturer’s data report. Registered units can be traced through the National Board. Paul Industries can then measure, inspect and document the unit so a re-rating or replacement rests on verified data.
When is a plastic heat exchanger the right choice?
When the process fluid would attack stainless or nickel alloys and the pressure and temperature sit inside the plastic’s limits. Hot acid baths, plating lines and high-chloride streams are typical. The larger surface area it needs has to be weighed against the cost of the alloy it replaces.
Who installs heat exchangers in process plants?
Paul Industries selects, installs and ties in shell and tube, plate, tube-in-tube and double-tubesheet heat exchangers for process plants. Units are set and oriented for drainability, access and CIP or SIP, then connected to product, steam, hot water, chilled water or glycol lines, with orbital-welded sanitary piping to ASME BPE on the process side. Weld, material and pressure-test records come with turnover.