Steam piping carries steam from the boiler to the equipment that uses it and brings the condensate back, and Paul Industries designs, fabricates, installs, tests and repairs steam piping, condensate returns and steam traps for industrial plants nationwide. A plant steam system is only as good as its distribution: a correctly sized boiler on badly drained pipe with failed traps still delivers wet, low-pressure steam, water hammer and a fuel bill nobody can explain.

What is steam piping?

Steam piping is the pressure piping that distributes steam through a plant: the header at the boiler, the steam mains that run through the building, branch lines to each user, drip legs and traps that remove condensate, and the condensate return that carries water back to the boiler room. Plant engineers treat steam and condensate systems as one design, because whatever the supply side gets wrong shows up on the return side as flooded coils, flash steam and corrosion.

Which type of steam a line carries changes the design. Saturated steam, the normal plant utility, is at its boiling temperature for its pressure and condenses the moment it loses heat, so every run must drain. Superheated steam is hotter than saturation, carries no water and is used mainly for turbines and some process duties. Wet steam carries water droplets that erode valves and cut heat transfer. Product-contact clean steam is a separate system with its own materials and tests; see pharmaceutical clean steam systems and clean steam versus plant steam.

Piping a steam boiler: near boiler piping and the header

Piping a steam boiler means connecting its outlets, header, mains and return so that water carried up with the steam falls back before it reaches the plant, and so that a leak in the return cannot drain the boiler. Near boiler piping is the part that does this, running from the boiler tappings through the risers and header to the first main and back through the equalizer, and the boiler maker’s piping diagram is the minimum standard for it.

Reading a steam boiler pipe diagram

PartJobDetail to check
Boiler steam pipe, or riserCarries steam and entrained water upward from the boilerEnough height for water to fall back, per the boiler diagram
HeaderSlows the steam so remaining water settles outRisers enter from the top or side, so one riser cannot drain into another
Main takeoffsFeed the plant or building mainsLocated after the last riser, so steam from each boiler riser passes them in one direction
EqualizerBalances pressure between the steam side and the return sideLast connection on the header, so condensate drains back to the boiler
Hartford loop, on low-pressure heating boilersLimits how far a return leak can drain the boilerReturn joins the equalizer below the water line through a close nipple or wye

A drop header steam boiler layout takes the riser above the header and then down into it, which gains riser height where the room is tight. On larger plant boilers, steam boiler pipe between the outlet nozzle and the stop valves falls under the code rules for boiler external piping covered below, so boiler piping design starts by marking where that boundary sits. A steam piping diagram for the full plant then carries on from there, showing every main, drip leg and return, and it should stay current after each change. Water carried over from a poorly piped boiler also reaches the feed side, covered under boiler water treatment.

Steam heat piping and the one pipe steam system diagram

Steam heat piping in commercial and institutional buildings comes in one-pipe and two-pipe forms, and steam pressure moves the steam to the radiators or coils with no circulating pump. A one pipe steam system diagram shows a single line to each radiator, with steam rising and condensate running back down the same pipe, so air vents and correct pitch are what keep it working. Two-pipe systems run a steam heating pipe to each unit and a separate return, with a trap at each outlet. Steam pipe heating at low pressure tolerates very little sag, because a steam heat pipe that holds water bangs and starves whatever is beyond it, and steam heat pipes in older commercial buildings often need their pitch reset after years of settling.

Steam systems piping for space heating usually sits under ASME B31.9, while steam piping systems feeding process equipment at higher pressure move up to B31.1 or B31.3. Paul Industries works on both and keeps the records the governing code requires.

Low pressure steam vs high pressure steam

The working boundary is 15 psig. What is low pressure steam? In US practice it is steam at 15 psig or less, the limit for heating boilers built to ASME Boiler and Pressure Vessel Code Section IV; boilers above it are power boilers under Section I. Plants often call roughly 15 to 100 psig medium pressure and anything higher high pressure, though those labels are custom rather than code. The choice between them is a trade: higher pressure packs more steam into a smaller pipe, while lower pressure gives more usable latent heat per pound and less flash loss.

Pressure (psig)Saturation temperatureLatent heat (Btu/lb)Specific volume (ft3/lb)Condensate flashing to atmosphere
0212 F97026.80%
15250 F94613.9About 4%
50298 F9126.7About 9%
100338 F8813.9About 13%
150366 F8572.8About 16%

The common pattern is to distribute at a higher pressure and reduce it with a pressure-reducing station near the users. Pressure also drives trap selection: a low pressure steam trap on a heating coil can see almost no differential when its control valve throttles, while a high pressure steam trap on a 150 psig drip needs a body and orifice rated for that differential. Values for any pressure are on our saturated steam table.

Steam piping sizing: velocity and pressure drop

Steam pipe sizing is set by two limits, velocity and pressure drop, and the pipe must satisfy both. Too small, and velocity erodes fittings and starves the far end of pressure; too large, and the plant pays for pipe, insulation and heat loss it does not need.

For saturated steam, engineering guidance puts steam velocity in pipes at roughly 25 to 40 meters per second, about 4,900 to 7,900 feet per minute, with long mains often held nearer 15 meters per second to limit pressure drop. A common pressure drop limit is about 0.1 bar per 50 meters, close to 0.9 psi per 100 feet. Because steam expands as pressure falls, the same mass flow needs a much bigger pipe at low pressure: a pound of steam occupies about 3.9 cubic feet at 100 psig and nearly 14 at 15 psig.

LineTypical design velocityDesign note
Saturated steam mains and branches4,900 to 7,900 ft/min (25 to 40 m/s)Check pressure drop on long runs; hold long mains lower
Rising mains, steam against condensate flowAbout 3,000 ft/min (15 m/s) or lessCondensate must run back against the steam
Superheated steamUp to about 9,800 to 13,800 ft/min (50 to 70 m/s)No droplets to erode, so limited by pressure drop
Condensate returns after trapsSized for the flash steam, not the waterA line sized for liquid alone floods and hammers

A steam pipe sizing table from a reference handbook is a starting point; good steam piping design then checks the actual load at each user, diversity, future additions and the pressure each user needs at its control valve. A steam riser that carries steam upward lets condensate run back against the flow, so it is sized for a lower velocity than a falling main. Pipe dimensions and weights are on our pipe schedule chart.

Steam pipe sizing tables and steam pipe dimensions

Pipe sizing for steam starts from the mass flow and the specific volume at working pressure, because the same pound of steam needs about 3.6 times the pipe area at 15 psig as at 100 psig. The table lists schedule 40 steam pipe dimensions in inches and the flow each size carries at 6,000 ft/min, which sits inside the velocity range given above.

NPSODWallBorelb/h at 15 psiglb/h at 100 psig
11.3150.1331.049155555
1 1/21.9000.1451.6103651,300
22.3750.1542.0676002,150
33.5000.2163.0681,3304,740
44.5000.2374.0262,2908,160
66.6250.2806.0655,20018,500
88.6250.3227.9819,00032,100
1010.7500.36510.02014,20050,500
1212.7500.40611.93820,10071,800

These figures come from bore area times velocity divided by specific volume (13.9 ft3/lb at 15 psig, 3.9 ft3/lb at 100 psig), rounded. They are a first pass: long mains usually fail on pressure drop before velocity, so check both. Steam pipe sizing tables in handbooks build in an assumed pressure drop and steam quality, which is worth reading before trusting a number. A steam pipe sizing calculator does the same arithmetic faster, and any steam piping sizing calculator is only as good as its inputs: actual pressure at the far end of the run, the equivalent length of valves and fittings, and the load the line will carry after planned additions. Specific volumes for other pressures are on our saturated steam table.

What type of pipe is used for steam?

Carbon steel. Plant steam lines are normally ASTM A53 Grade B or ASTM A106 Grade B pipe with butt-weld fittings to ASME B16.9, forged socket-weld or threaded fittings to ASME B16.11 on small bore, and flanges to ASME B16.5. Schedule 40 is the usual wall for steam in common sizes. Does steam piping need to be seamless? Not for most plant service: A53 electric-resistance-welded pipe is permitted, though its weld joint factor lowers its allowable stress, and many owners specify seamless A106 for higher pressures and temperatures.

Does steam pipe need to be schedule 80? Not as a rule, but schedule 80 is common for threaded small-bore lines, where the threads remove wall, and for condensate returns, where carbonic acid thins the pipe from the inside. That acid forms when carbon dioxide released from feedwater alkalinity dissolves in condensate, and it typically grooves the bottom of the pipe and attacks threads just downstream of traps. Can steam pipe be threaded? Yes, on small sizes in moderate service, usually 2 inch and under; larger and higher-pressure lines are welded. Use a thread sealant for steam piping that is rated for the steam temperature, not a general plumbing compound. Will steam melt PVC? It will soften and fail: PVC pressure pipe is rated to about 140 F, so plastic has no place on steam or hot condensate. Stainless condensate lines are covered on our stainless steel piping page.

Steam piping code: B31.1, B31.3 and B31.9

The governing code depends on the boiler, the facility and the owner’s specification, and it should be named in writing before design starts.

CodeWhere it appliesPractical effect
ASME B31.1 Power PipingBoiler external piping on Section I boilers, power and central plants, and many industrial steam systems by owner choiceBoiler external piping is also under the boiler code’s jurisdiction, with inspection and stamping requirements
ASME B31.3 Process PipingSteam and condensate inside chemical, pharmaceutical, food and refining process unitsFluid service categories set the examination required
ASME B31.9 Building Services PipingBuilding and light industrial service: steam and condensate to 150 psig and 366 FLighter requirements; steam above its limits moves to B31.1

Welders and procedures are qualified under ASME Section IX whichever book governs, and new lines are pressure tested, normally hydrostatically at not less than 1.5 times design pressure. Steam boiler piping between the boiler and its stop valves, including the header and the valves the boiler code requires, is boiler external piping and is the part most often inspected by the jurisdiction.

Pipe slope, drip legs and drainage

Steam mains are pitched down in the direction of flow so condensate runs to drain points, and every low point gets a drip leg and a trap. Engineering guidance calls for a steam piping slope of at least 1 in 100 with the flow, and 1 in 40 where a line must rise so condensate runs back against the steam. Drip legs go at every low point, at the end of each main, ahead of risers, control valves and pressure-reducing stations, and along straight runs at intervals of about 100 to 165 feet, closer on rising runs.

A drip leg is a full collecting pocket, not a small tap off the bottom of the pipe. On mains up to 4 inch the pocket is the same diameter as the main; on 5 to 8 inch mains it is typically 4 inch; on 10 inch and larger it is at least half the main diameter, with depth increasing accordingly. The trap connection sits a little above the bottom so dirt collects below it. Good steam trap piping also puts a strainer and blowdown valve ahead of the trap, isolation valves and a test or sight point after it, and a union or flange so the trap can be removed. Where should steam traps be installed? Below the equipment or drip leg they drain, close to it, with condensate falling to the trap by gravity. The valves, strainer, trap, test point and any check valve together make up the steam trap assembly, often shop-built as a trap station. Steam trap vs strainer is not a choice, because the strainer is what keeps scale and weld debris off the trap seat; a steam trap with strainer built into the body saves space where stations are crowded. Reducers in steam mains are eccentric with the flat side on the bottom, and strainer baskets on steam lines are turned to the side so they do not hold a pool of water.

Why do steam pipes bang?

Steam pipes bang because condensate collects in the pipe and the steam either drives a slug of water into a fitting at high speed or collapses into the cold water and lets it slam shut. That is water hammer, and it is a structural hazard, not just a noise: it splits fittings, blows gaskets and damages traps and valves. The usual causes are a missing or failed drip trap, pipe that sags between supports into a low spot, a concentric reducer that holds a puddle, a flooded condensate return, and opening a valve too fast on a cold line. The fix is mechanical: restore the slope, add or repair drip legs, replace failed traps, size the return for flash steam and warm lines up slowly with drains open. Steam trap troubleshooting is often where a water hammer investigation ends, because a failed-closed drip trap, or a return flooded by failed-open traps, is the usual source.

Expansion, supports and anchors

Carbon steel grows about 2 1/4 inches per 100 feet between 70 F and 350 F, so a steam main has to be told where to move. A steam pipe anchor fixes the pipe at chosen points, guides keep it aligned between anchors, and the growth is absorbed by expansion loops, offsets or an expansion joint for steam piping where there is no room for a loop. Expansion joints need anchors designed for the pressure thrust they create. Steam line expansion joints are bellows or packed slip types; bellows joints need pipe guides close on each side, and slip joints need their packing maintained. Steam pipe supports must allow the pipe to slide, with roller or slide supports and spring hangers where vertical movement occurs, and they must hold the slope: a support that fails and lets the pipe sag creates a water pocket and the water hammer that comes with it.

Steam pipe line details: material, pitch, valves and supports

A steam pipe line stays dry and tight when its material, pitch, valves and supports are checked together, because a fault in any one shows up as water hammer or a leak somewhere else on the run.

ItemRule of thumbField check
Steam pipe materialCarbon steel for mains and branches, with heavier wall or stainless on return lines that corrodeMill test reports and marking match the line class
Steam pipe pitch1 in 100 with the flow, about 1/8 inch per foot; 1 in 40, about 0.3 inch per foot, where condensate runs back against the steamLevel or laser survey after hangers are set, and again after the first heat-up
Steam pipe valveGate valves for full-open isolation, globe valves for throttling and warm-up bypassesBody class suits pressure and temperature; stem and handwheel reachable
Steam piping supportsRollers or slide plates under moving lines, spring hangers where the line also moves verticallyShoes still on their supports when hot, and no hanger bottomed out

Steam piping material on the condensate side deserves its own line class, since it sees carbonic acid and flash erosion that the supply side does not. Isolation valves on larger mains are normally fitted with a small warm-up bypass, so the line heats slowly and its drip legs keep pace. Supports should be walked hot and cold during commissioning, because a shoe that has walked off its steel is a future sag point. Hanger and anchor work is part of our pipe fabrication and field scope.

Steam traps on a steam piping system

Every drip leg, heat exchanger, coil and tracer on a steam system ends in a steam trap. What is a steam trap? It is the self-acting valve that tells live steam from condensate and lets only the condensate, air and other non-condensable gases through. So what does a steam trap do for the pipe itself? It keeps the mains drained, so users get dry steam at full pressure and water never collects into the slugs behind most water hammer. What is the purpose of a steam trap beyond drainage? Returning hot, already-treated condensate to the boiler room instead of losing it, and venting the air that would otherwise blanket heat transfer surfaces at start-up.

How does a steam trap work? It senses the difference between steam and condensate by density, temperature or velocity, which gives the three families that ISO 6704 classifies, and ASME PTC 39 covers how their performance is tested. The steam trap function is the same in every family; what differs is how fast each vents air, how much condensate it holds back and how it copes with back pressure, dirt and hammer.

Steam trap typesFamily and what it sensesUsual place on the pipingWatch for
Inverted bucket steam trapMechanical: densityDrip legs on mains, general processVents air slowly; orifice must suit the maximum differential
Float and thermostatic steam trapMechanical: density, with a thermostatic air ventHeat exchangers, coils, modulating loadsFloat can be damaged by hammer; body can freeze outdoors
Thermodynamic steam trapVelocity and pressure of flashing condensateDrips on medium and high pressure mains, tracersUnreliable at very low differential or high back pressure
Balanced pressure thermostatic steam trapTemperature, adjusting to pressureAir venting, tracing, start-up loadsBacks condensate up before it opens
Bimetallic steam trapTemperatureHigh pressure drips, tracing, corrosive condensateSlow to respond to load changes; needs a cooling leg

A mechanical steam trap discharges condensate at steam temperature as fast as it forms: the inverted bucket floats shut when steam fills it, and a ball float steam trap opens in proportion to the condensate level. A plain float has no way to vent air, which is why the F&T steam trap adds a thermostatic element. A thermostatic steam trap opens only when condensate cools below steam temperature; in balanced pressure designs the steam trap bellows or capsule holds a fill that boils just below steam temperature, so it expands and closes as steam arrives. The disc steam trap is the thermodynamic type, with one moving part snapped shut by flash steam passing under the disc and steam trapped above it.

Which steam trap is best depends on the duty: inverted bucket or thermodynamic on mains drips, float and thermostatic on heat exchangers and modulating coils, thermostatic on tracing. The thermostatic vs thermodynamic steam trap question usually comes up on tracers and drips. Thermostatic traps subcool condensate, which suits tracing but floods a heat exchanger; thermodynamic traps discharge near steam temperature and tolerate superheat and vibration, but typically need about 3.6 psig (0.25 bar) at the inlet and a back pressure under about 80 percent of inlet pressure.

Steam trap sizing starts from the condensate load and the real differential across the trap, which is the inlet pressure minus the back pressure in the return, never from the size of the pipe; a cold main at start-up produces far more condensate than it does running. Can you oversize a steam trap? Yes, and it is a common fault: an oversized trap cycles hard, wears early and wastes more steam when it fails, because the steam trap orifice sets how much passes a trap that has failed open. Sizing a steam trap therefore means reading the maker’s capacity chart at that real differential and applying the maker’s safety factor. Where a coil’s pressure can fall below the return pressure, or condensate has to lift to an overhead return, a pressure-powered steam trap pump moves it.

How often should steam traps be inspected depends on pressure: DOE guidance is weekly to monthly at 150 psig and above, monthly to quarterly from 30 to 150 psig, and at least annually below 30 psig. A steam trap survey tests and tags every trap and records it as working, failed open, failed closed or leaking, so losses can be priced; a failed-open trap with a 1/8 inch orifice at 100 psig passes about 52.8 lb of steam an hour. Steam trap testing combines temperature, sound and a visual check at a test valve, because no single method is reliable alone. Ultrasonic steam trap testing hears whether a trap cycles or passes steam through its seat, and knowing how to test a steam trap includes reading that by type: bucket and disc traps should be heard cycling, while F&T traps flow steadily with load. A handheld steam trap tester covers the survey walk. Steam trap monitoring covers the critical traps between surveys, and a wireless steam trap monitor on a high-pressure drip reports a failure within hours.

Steam trap repair is worth doing when the body is sound and the trap is the right type and size: a steam trap repair kit renews the seat, valve and mechanism, and universal-connector designs let the trap module be changed without cutting pipe. Sealed traps, and wrong-type or oversized traps found in a survey, call for steam trap replacement with a correct selection. Steam trap maintenance then keeps strainers clean, test valves working and the trap register current. On the piping side, condensate must fall to each trap by gravity, a strainer protects it, each piece of equipment has its own trap rather than sharing one, the discharge line is sized for flash steam, and there is a way to isolate and test it. Trap selection, surveys, repair and replacement are covered in depth on our dedicated steam traps page.

How does a condensate return system work?

Condensate leaves each trap, part of it flashes to steam at the lower return pressure, and the mix flows by gravity or residual pressure to a receiver, where a pump returns the water to the boiler feed system. Returned condensate is hot, already-treated water: the DOE notes that it typically comes back at 130 to 225 F against 50 to 60 F makeup, and that it can hold more than 10 percent of the energy in the steam. Good steam condensate piping design sizes returns for the flash steam volume, slopes them toward the receiver, keeps lifts after traps to a minimum, and recovers flash steam at a flash vessel where a low-pressure user can take it. The deaerator and feedwater side is covered on our boiler feedwater and deaerator page.

Condensate return tank and steam condensate return pump sizing

A condensate return tank collects condensate at atmospheric pressure, and the steam condensate return pump sends it to the boiler feed system, commonly at two to three times the evaporation rate of the boiler it serves so that the pump can stay ahead of production. A condensate return unit packages the receiver, pump, float switch and vent as one assembly, in simplex or duplex form.

Temperature decides whether the pump can run at all. A vented receiver holds the suction at atmospheric pressure, so the hotter the water, the less net positive suction head remains.

Condensate temperatureNPSH available from a vented receiver at sea level, before suction line losses
200 F7.5 ft
204 F5.1 ft
206 F4.0 ft
208 F2.6 ft
210 F1.4 ft
212 F0 ft

A steam condensate return pump system near boiling therefore needs a low-NPSH pump, a raised receiver for extra static head, or lower-temperature condensate, and failed-open traps upstream are a common reason a unit that worked for years begins to cavitate. Receivers are sized for a stated net storage at the return rate, commonly one minute or more; too small a tank short-cycles the pump. A steam condensate drain cooler handles the hot drains that cannot be returned, mixing or exchanging them down to the discharge limit, which building drainage codes generally set at 140 F. Our deaerator page covers where the returned water goes next.

Do steam pipes need to be insulated?

Yes, for energy, safety and condensate control. DOE figures put the loss from 100 feet of bare 2 inch line at 150 psig at about 480 million Btu a year, and 100 feet of bare 4 inch at 15 psig at about 415 million Btu, with insulation typically cutting those losses by 90 percent; DOE recommends insulating any surface over 120 F. Steam piping insulation is usually mineral wool, calcium silicate, fiberglass or cellular glass, with aluminum or stainless jacketing outdoors. Thickness is set for heat loss and for personnel protection, where ASTM C1055 guidance on contact burns usually leads to an outer surface no hotter than about 140 F. Valves, strainers and flanges get removable jackets, and steam pipe lagging that is wet or missing after a repair should be replaced, because wet insulation loses most of its value and corrodes the pipe beneath it.

Installation, welding and testing

Steam piping installation follows the same sequence on every job: confirm the code and the specification, fabricate spools in the shop where possible, set anchors, guides and supports before the pipe, hold the slope and drip leg locations from the design, then test, clean, insulate and commission. Steam pipe welding is done under qualified procedures with qualified welders, by manual stick or TIG root with stick or MIG fill on carbon steel, with examination to the code. After the hydrostatic test, new steam lines are blown down to clear mill scale and weld debris before traps and control valves see steam. Steam trap installation follows that blowdown, so construction debris never reaches a new trap seat. Shop spools and field crews are part of our process piping work, and tie-ins to running plants are usually planned into shutdowns and turnarounds.

Steam leaks, repair and service life

A steam pipe leak is a safety problem first: steam at 100 psig is at 338 F, and a pinhole can cut skin and is often invisible close to the hole. Steam pipe repair options run from a temporary steam pipe repair clamp, rated for the pressure and temperature, to cutting out the damaged section and welding in new pipe, which is the lasting repair. Leaking condensate pipe usually means carbonic acid grooving that will be found elsewhere on the same line. A steam trap leak at a body gasket, cap or end connection is logged and repaired the same way, while steam passing through the seat means the trap itself has failed. Steam piping life expectancy is long, often decades for well-drained, well-supported steel mains, and much shorter for condensate lines in plants with high feedwater alkalinity or failed traps. Urgent failures are handled by our emergency repair service.

Steam piping best practices

The checklist that prevents most failures is short: drain every low point with a proper drip leg and trap, slope every main, use eccentric reducers, size returns for flash steam, anchor and guide for expansion, insulate everything over 120 F, survey traps on a schedule, and keep as-built drawings and a trap register current. Every steam line in a plant should appear in that register, from the boiler header to the farthest drip.

What Paul Industries does

Paul Industries designs, fabricates and installs complete steam piping system scope: boiler headers, steam mains and branches, pressure-reducing stations, drip legs and trap stations, condensate returns, flash recovery, receivers and pumps, expansion loops, anchors and supports, testing, blowdown, insulation coordination and commissioning. We survey, test, repair and replace steam traps, carry out leak repair, and maintain steam systems under plant utilities service, alongside compressed air and process gas lines and heat exchangers. Every industrial steam trap we fit is selected for its duty, pressure and load rather than matched to whatever was there before. We install and service traps, valves and boiler-room piping, working with equipment from all the major manufacturers. Request a quote for steam piping, a trap survey or a repair.

Standards referenced: ASME B31.1 · ASME B31.3 · ASME B31.9 · ASME BPVC Section I · ASME BPVC Section IV · ASME BPVC Section IX · ASTM A53 · ASTM A106 · ASME B16.5 · ASME B16.9 · ASME B16.11 · ASTM C1055

Frequently asked questions

What does a pressure-reducing station need?

A strainer and separator or drip ahead of the reducing valve, isolation valves and a bypass, pressure gauges on both sides, and a safety relief valve on the low-pressure side sized for the full flow the reducing valve can pass if it fails open. Downstream piping is sized for the larger volume of the lower-pressure steam.

Can PVC or PEX be used for steam or condensate?

No. PVC pressure pipe is rated to about 140 F and PEX is a hot-water product; steam and flashing condensate are well above those temperatures. Steam and condensate lines are steel, with stainless or copper in some condensate service.

Which code applies to plant steam piping?

ASME B31.1 for boiler external piping and power or central plant steam, ASME B31.3 inside process units, and ASME B31.9 for building and light industrial service up to 150 psig and 366 F. Many owners specify B31.1 for all plant steam. The governing code should be stated in the specification.

What is the difference between a drip leg and a dirt leg?

A drip leg is a full-size pocket at a low point in a steam main that collects condensate for a trap to discharge. A dirt leg is a short pocket ahead of equipment, such as a gas or steam connection, that catches scale and debris. On steam mains the drip leg does both jobs by placing the trap connection above the bottom of the pocket.

Why is wet steam a problem?

Water droplets moving at steam velocity erode valve seats and fittings, carry less heat than the same mass of dry steam, and leave a water film on heat transfer surfaces that slows heating. Drainage, separators ahead of critical users and correct boiler water level keep steam dry.

How is condensate return pipe sized?

For the flash steam, not the water. When condensate passes a trap into a lower-pressure return, part of it flashes to steam, about 13 percent of the mass for condensate going from 100 psig to atmosphere, and that vapor takes up most of the volume. A return sized for liquid alone floods, backs up traps and hammers.

Can steam pipes freeze?

Yes, when the steam is off. A line that is shut down in winter fills with condensate at every low point and undrained trap, and that water freezes and splits pipe, fittings and trap bodies. Outdoor and unheated runs are drained when they are taken out of service, drip legs are fitted with freeze-resistant traps or drains, and lines that must stay idle under cover are heat traced.

Why do steam pipes have bends and loops?

To absorb thermal expansion. A carbon steel main grows a little over 2 inches per 100 feet between ambient and 350 F, and an expansion loop or offset lets that growth flex the pipe instead of pushing on anchors, equipment nozzles and branch connections. Where there is no room for a loop, a bellows or slip expansion joint does the same job between anchors.

How thick should steam pipe insulation be?

It depends on the steam temperature, the pipe size, the insulation material and the job it has to do. Thickness is normally set by an economic heat-loss calculation, for example with the NAIMA 3E Plus program, checked against the energy code that applies to the building, and then checked again for personnel protection so the jacket surface stays at or below about 140 F.

What is a condensate return pump?

A receiver tank with a pump that sends collected condensate back to the boiler feed system. Electric units start and stop on a float or level switch in the receiver; pressure-powered pumps use steam or compressed air as the motive force and suit hot condensate and hazardous areas, where electric pumps can cavitate or are not allowed. The receiver is vented so flash steam does not pressurize the return.

Are steamfitters and pipefitters the same?

Steamfitting is a specialty within pipefitting. The US Bureau of Labor Statistics describes steamfitters as pipefitters who specialize in installing systems that move steam under high pressure, and both install industrial pressure piping. Plumbing is the related specialty that covers potable water, drainage and fixtures.

What is a steam header?

The large-bore pipe at the boiler room that collects steam from one or more boilers and distributes it to the plant mains. It is sized for low velocity so it also acts as a separator, sloped to a drain point with a drip leg and trap at its low end, and fitted with the stop valves and branch connections for each main.

What is flash steam and can it be recovered?

Flash steam forms when hot condensate drops to a lower pressure, for example when it passes a trap into the return; about 13 percent of the mass flashes when condensate goes from 100 psig to atmosphere. It can be recovered in a flash vessel that separates it from the water and feeds it to a low-pressure user such as a heater or the deaerator, as long as that user needs steam whenever the flash is produced.

Can a steam trap fail closed?

Yes. Dirt on the seat, a blocked strainer, air binding, a failed thermostatic element, or a differential higher than the orifice was designed for can all leave a trap shut. On a main, the drip leg fills and the next slug of condensate is carried down the line as water hammer; on a heat exchanger, the shell floods and output drops. A trap that is cold on both sides usually points to a closed isolation valve or a blockage upstream instead.

Is a steam trap a check valve?

No. Some trap designs resist reverse flow, but a trap is not built to hold back the return. Where condensate lifts to an overhead return after the trap, or several traps discharge into a common return that can be pressurized, a separate check valve is fitted after the trap so the return cannot flow back into the trap and the equipment.

How long do steam traps last?

There is no fixed life: it depends on trap type, sizing, pressure, water hammer and dirt. The DOE reports that in systems left unmaintained for three to five years, 15 to 30 percent of traps can be failed, while a regular program keeps failed traps under 5 percent, which is why traps are managed by testing rather than replaced by age.

Can steam traps be repaired?

Many can, in line. Repairable traps take a new seat, valve and mechanism, and universal-connector traps let the module be swapped without breaking the pipe joints. Sealed traps are replaced. Either way the strainer is cleaned and the selection is checked against the load and differential before the trap goes back into service.

Do you install steam piping in operating plants?

Yes. Spools are fabricated in our shop, tie-ins are planned for shutdown windows, and new sections are tested, blown down and warmed in a controlled sequence before they are put into service.

Why are my steam pipes knocking only at start-up?

Cold pipe condenses steam fastest in the first minutes, so drip legs and traps see their heaviest load during warm-up. Steam pipes knocking at that point usually means the warm-up is too quick or a low-point drain is missing or blocked. Open the drains, bring steam in slowly through a bypass, then test the traps and check the pitch.

What causes steam pipe hammering after a shutdown?

Condensate left sitting in low spots after the line cools is the usual cause, because the next steam admission drives it along the pipe. Steam pipe hammering stops once the line is drained before each restart and any sagged section between supports is corrected.

What does steam pipe leak repair involve?

It starts with isolating the line, confirming zero pressure and letting it cool, then finding why the metal failed. Steam pipe leak repair is finished by welding in a new section under a qualified procedure and retesting, with a rated clamp available as a stopgap until the outage. Grooved condensate lines get thickness readings beyond the repair, because the same attack is usually present along the run.

Who installs and repairs steam piping?

Paul Industries designs, fabricates, installs and repairs steam piping, from boiler headers and mains to pressure-reducing stations, drip legs and condensate returns. Lines are pitched toward drainage points so condensate clears before it can slug, expansion loops and anchors are set for the run, and the finished system is tested to the governing ASME B31 code, including work inside operating plants.

How much does steam piping cost?

Steam piping cost follows operating pressure and the code it sets, whether ASME B31.1, B31.3 or B31.9, along with pipe size and schedule, welded or threaded joints, and how many trap stations, drip legs and expansion loops the route needs. Condensate return, insulation and hot work in a running plant add to the figure, so a quote starts from the line list and a site walk.

Related: Plant Utilities: Steam, Heating, Chilled Water & Ice Builders · Pharmaceutical Clean Steam Systems · Boiler Water Treatment · Process Piping · Stainless Steel Piping · Meat And Poultry Plant Utilities And Piping · Request a quote · Deaerator Installation, Inspection and Service · Hydrostatic Testing of Piping, Vessels and Tanks · Shell and Tube Heat Exchanger: Parts, TEMA Types, Design and Sizing · Heat Tracing: Electric and Steam Tracing Design, Installation and Service · Mechanical Insulation for Industrial Piping, Tanks and Equipment · Hydronic Piping: Types, Materials, Sizing, Design and Installation · Pipe Color Code Chart and Pipe Labeling Standards (ASME A13.1) · Boiler Repair for Commercial and Industrial Steam and Hot Water Boilers · Industrial Valve Repair: Control Valve Repair, Relief Valve Testing and Rebuilds