Paul Industries provides tank fabrication in South Dakota for ethanol plants, dairies and cheese makers, packing plants, fuel and chemical users and water systems, building carbon steel and stainless storage and process tanks and carrying them through the notification, plan approval, containment and testing that South Dakota’s aboveground tank rules require. The work runs from design and fabrication through foundations, setting, piping, coatings, cathodic protection and the records DANR expects. Plants buy tanks supply-only, as skid packages, or installed complete.

Request a quote or call 201-450-8280

Headquarters 256 Shore Drive, Kilmarnock, Virginia
Tank agency Department of Agriculture and Natural Resources (DANR)
Before installing Notify DANR 30 days ahead and get plan approval (ARSD 74:56:03:02)
Containment 110 percent of the largest tank (ARSD 74:56:03:11)
Internal inspection Every 10 years once upgraded; tanks of 25,000 gallons or less exempt
Reviewed November 2026

What does tank fabrication in South Dakota have to meet?

Tank fabrication in South Dakota has to meet the construction standard for the tank’s service, such as API 650, UL 142, AWWA or 3-A, and, for tanks holding petroleum or other regulated substances, the storage tank rules of the Department of Agriculture and Natural Resources in ARSD chapter 74:56:03 for aboveground tanks and chapter 74:56:01 for underground ones. State law requires the aboveground rules to be exercised in substantial conformity with NFPA 30, the Flammable and Combustible Liquids Code, and NFPA 30A for motor fuel dispensing, both cited to their January 1, 2024 status in SDCL 34A-2-101. The rules apply from the design stage onward: plans are approved before installation starts, and a tank cannot be set first and permitted afterward.

Product and process tanks that hold milk, whey, mash, water or food ingredients sit outside the petroleum rules and answer to food and sanitary standards instead. The national picture of tank types, materials and the general build sequence is on the tank fabrication service page. This page covers what a South Dakota buyer needs to know about the state’s rules, its climate and its plants.

What is considered an above ground storage tank in South Dakota?

An above ground stationary storage tank in South Dakota is any stationary tank, or combination of tanks with connected pipes, that sits above ground and stores a regulated substance, which SDCL 34A-2-98 defines as CERCLA hazardous substances other than hazardous waste, together with petroleum that is liquid at standard conditions. The answer to what is considered an above ground storage tank also depends on the exclusions in SDCL 34A-2-100 and ARSD 74:56:03:01, which leave several common tanks outside the program:

  • farm or residential tanks storing motor fuel for noncommercial use;
  • tanks storing heating oil or motor fuel for consumptive use on the premises where they sit;
  • flow-through process tanks, septic tanks, storm water and wastewater collection systems, and surface impoundments;
  • tanks in a basement, cellar or mine working that stand on or above the floor;
  • pesticide tanks regulated under chapter 38-21;
  • portable tanks on wheels, skids or pallets, and drums of 55 gallons or smaller.

The consumptive-use exclusion is the one buyers ask about most: a generator day tank or a boiler fuel oil tank serving the building it stands beside is outside the state AST rule, while a bulk fuel tank that dispenses to vehicles or customers, or a chemical tank holding a CERCLA substance, is inside it. Federal rules can still reach an excluded tank. Are above ground storage tanks regulated by the EPA? Oil storage is, through the Spill Prevention, Control, and Countermeasure rule in 40 CFR 112, which applies to a facility with more than 1,320 gallons of aboveground oil storage in containers of 55 gallons or more that could reach navigable waters, and a plant often needs an SPCC plan whether or not DANR regulates the individual tank.

South Dakota aboveground storage tank regulations, step by step

The South Dakota aboveground storage tank regulations in ARSD 74:56:03 set out a sequence for every new regulated tank, from notice through annual inspection, and each step leaves a record the department can ask to see. The order matters because two of the steps carry 30-day lead times.

New regulated aboveground tank in South Dakota: the rule-by-rule sequence
StepARSD sectionWhat it requires
Notification74:56:03:02Notice to DANR and any designated agency at least 30 days before installation, on the department’s form, one form per place of operation
Plan approval74:56:03:02 and :11Department approval of plans and specifications before installation begins; containment plans submitted at least 30 days before construction
Construction standard74:56:03:07A code of practice such as UL 142, or a similar method the department approves
Installation74:56:03:10Manufacturer’s instructions and a code such as API 650 or UL 142; stable, well-drained foundations that resist settling and bottom corrosion
Corrosion protection74:56:03:07 and :10Cathodic protection for metal in contact with soil or an electrolyte, designed for 20 years under a qualified engineer or corrosion expert, with a test station
Protection choice74:56:03:04Performance standards with overfill control, secondary containment, or release detection, at least one of the three
Testing74:56:03:10Tests before operation to API 510, API 650, UL 142 or a similar method
Certification of compliance74:56:03:03Owner’s form covering installation, containment, release detection and cathodic protection, with the installer certifying the methods used
Operation74:56:03:17Daily inventory, or weekly with secondary containment; monthly reconciliation; devices, gauges and cathodic protection checked twice a year

Paul Industries builds that sequence into the project schedule. The notification and plan package goes in while the tank is in design, containment drawings go to the department with their own 30-day margin, and fabrication proceeds in parallel so approval and delivery land together. The installer’s certification is completed from the actual installation records, and the owner receives a binder that answers each line of the compliance form.

Aboveground storage tank secondary containment requirements in South Dakota

The aboveground storage tank secondary containment requirements in ARSD 74:56:03:11 call for containment under and around a new tank that holds 110 percent of the volume of the largest tank in the facility, unless the tank uses double walls or a double bottom. Containment may be a combination of double-walled tanks, dikes, liners, pads, curbs, sumps or receiving tanks, and diking is built to professional engineering practice.

The containment requirements for aboveground storage tanks in South Dakota also set the materials. The floor and walls of the containment are native soil, clay, bentonite or a manufactured liner equivalent to 60 mil high-density polyethylene or better, with an impermeability of at least 10-6 centimeters per second, maintained for the life of the tank system. Containment has to be compatible with the stored product and designed to control storm water, and rainwater or discharges from the containment may need a surface water discharge permit. In a South Dakota winter, that last point is practical as well as legal: snowmelt and rain collect in a dike, freeze and thaw, and need a valved, normally closed drain and a written procedure for checking the water before it is released.

Paul Industries designs containment alongside the storage it protects: concrete dikes with sealed joints and coated interiors for bulk fuel and chemical storage, steel dikes and curbs for smaller tanks, and double-walled UL 142 units where space is tight. Overfill protection under 74:56:03:13 is specified at the same time, with high-level alarms wired apart from the gauging, so the containment rarely has to do its job.

How often should above ground storage tanks be inspected in South Dakota?

South Dakota answers how often should above ground storage tanks be inspected in two layers: routine owner inspections under ARSD 74:56:03:17 and internal inspections under 74:56:03:05. Routine inspection means daily inventory measurements, or weekly where the tank has secondary containment, monthly inventory reconciliation, and a check of overfill devices, release detection instruments, gauges, valves and cathodic protection at least twice a year, never more than 7 1/2 months apart.

Internal inspection intervals for South Dakota aboveground tanks (ARSD 74:56:03:05)
SituationInternal inspection interval
Tank of 25,000 gallons or lessExempt from the internal inspection requirement
Facility of 250,000 gallons or less, before meeting a protection optionEvery two years
Facility of 250,000 gallons or less, after meeting a protection optionEvery ten years
Same facility relying on release detection aloneEvery five years
Facility over 250,000 gallons, before meeting a protection optionEvery two years
Facility over 250,000 gallons, after meeting a protection optionEvery ten years

Two smaller requirements catch owners out. New tanks holding noncorrosive substances need no internal coating, but ARSD 74:56:03:07 then requires the pH of the tank condensate to be sampled twice a year, no more than 7 1/2 months apart, and held at 6.8 or higher. And a tank removed from service for more than 24 months must be permanently closed under 74:56:03:28. Paul Industries cleans vessels for internal inspection, performs the inspection work and repairs that follow, and supplies replacements where closure is the better answer.

Repairs, reuse and closure of regulated tanks

Repairs to a regulated aboveground tank in South Dakota are allowed under ARSD 74:56:03:16 when the owner documents that the repair is permanent, the tank meets new-tank standards, the tank and its lining are compatible with the product, the tank was inspected internally, sludge was removed and disposed of properly, and welds and patches follow accepted industry codes. Repaired piping and fittings are restored to at least original condition and tested before the system returns to service, and the owner keeps the records.

Paul Industries performs bottom and shell repairs, nozzle replacements, relining and re-coating, and the testing that proves them, with the written record the rule calls for. Used units moved to a new site are treated as new installations for notification and plan approval, and are inspected and evaluated before purchase; where the evaluation shows thin bottoms or a missing nameplate, new construction usually costs less in the end. For the cleaning and preparation side, Paul Industries also provides industrial tank cleaning before inspection, repair or closure.

South Dakota underground storage tanks

South Dakota underground storage tanks follow ARSD chapter 74:56:01, which ties tank and piping installation to the codes of practice listed in the federal UST rule at 40 CFR 280.20 and requires the owner to certify compliance on the state notification form. The South Dakota underground storage tank regulations cover any tank system with 10 percent or more of its volume below ground, including connected underground piping, and they reach emergency generator tanks, which became fully regulated on October 13, 2018. Systems of 110 gallons or less are outside the rule, as are farm or residential motor fuel tanks of 1,100 gallons or less used noncommercially and heating oil tanks for use on the premises.

Aboveground tanks with containment are the usual alternative to a new underground system, because leaks are visible and inspection is simpler. Paul Industries supplies and installs both, and handles the piping, sumps, leak detection connections and the documentation for either route.

Tanks for South Dakota ethanol, dairy, food and water service

Tanks for South Dakota plants follow the state’s processing industries, each with its own construction standard and its own reason to buy. Ethanol plants store denatured ethanol, gasoline denaturant, process water and stillage; the EIA counts 16 plants in the state with about 1.5 billion gallons of annual capacity, against in-state use of about 50 million gallons, so most of that output is stored on site before it ships to other states. Dairy and cheese plants in Brookings, Lake Norden and Milbank store raw milk, whey, cream, brine and cleaning solutions, and Bel Brands’ expansion in Brookings, due in early 2028, is set to double the plant’s milk use from 650,000 pounds a day.

Tank types for South Dakota plants and the standards they are built to
ServiceTypical tankConstruction standardSouth Dakota design point
Denatured ethanol and denaturantField-erected or shop-built carbon steel, internal floating roofAPI 650; NFPA 30DANR AST notification, containment, overfill alarm
Bulk diesel and fuel dispensingUL 142 single or double wallUL 142; NFPA 30ARegulated when dispensing; containment or double wall
Raw milk and whey silosInsulated stainless silos with sloped bottoms3-A Sanitary StandardsOutdoor insulation and heated outlet enclosures
CIP and brineStainless process tanks with heating or cooling3-A practice; ASME BPE fittingsChloride-resistant alloy for brine
Process water and stillageCarbon or stainless with coatingsAPI 650 or AWWA D103Chloride level in recycled water sets the material
Fire and potable waterWelded or bolted steel reservoirsAWWA D100 or D103; NFPA 22Freeze protection on inlets, outlets and vents
Chemical storageCarbon, stainless or lined steelAPI 650, UL 142 or API 620Regulated when holding a CERCLA substance

Custom stainless steel tank fabrication for dairy and food plants follows sanitary rules more than storage rules. Stainless steel tanks for milk are built with product-contact finishes, sloped and fully drainable bottoms, sanitary manways and spray devices, and insulation and cladding that keep the product cold and the exterior washable. Stainless steel tank design standards for that service come from 3-A Sanitary Standards and ASME BPE for fittings and finishes, and the tank’s welds are documented, ground and passivated so they clean as well as the parent metal.

How are stainless steel tanks made for South Dakota plants?

Stainless steel tanks for South Dakota plants are made by rolling and welding shell courses, forming heads or cones, cutting and reinforcing nozzles, welding with procedures qualified to the service, then grinding, polishing, passivating and testing before insulation and cladding go on. How are stainless steel tanks made to survive the trip and a South Dakota winter is a design question too: lifting lugs and shipping saddles are designed with the tank, and outdoor silos get insulation with sealed jackets and heated outlet enclosures so valves and sample ports keep working at the 1.9 degree January normal low NOAA records for Aberdeen.

How long do stainless steel tanks last? A well-built 304L or 316L tank in milk, water or mild process service routinely lasts decades; the things that shorten it are chlorides, hot concentrated cleaning chemicals, poor drainage and damaged passive layers. Paul Industries picks the alloy from the actual fluid, documents the welds and passivation, and offers passivation services in South Dakota for tanks already in service. Fabricated steel tanks in carbon steel, for fuel, water and many chemicals, last as long as their coatings and cathodic protection are kept up, which is why the South Dakota rule requires a 20-year cathodic protection design.

Shop-built or field-erected for a South Dakota site?

Shop-built or field-erected is the first construction decision on a large South Dakota order, and the answer turns on diameter, height and the route to the site. Vessels up to roughly the width that can ride a truck legally or with an oversize permit are welded, tested and coated off site, then delivered and set in a day, which keeps the plant’s exposure to cutting and welding short. Larger diameters are erected on a prepared foundation course by course, with the bottom, shell and roof welded, examined and tested in place under API 650.

The South Dakota calendar shapes field erection. Concrete foundations and ring walls are poured when the ground and the weather allow curing, welding in the open follows cold-weather preheat practice, and hydrostatic testing with water needs above-freezing conditions or a heated test plan. Paul Industries schedules field-erected work so the foundation and test fall in the warmer months and the shop-built pieces, such as roofs, nozzles and stairs, are ready before the erection crew starts. Coatings, cathodic protection and insulation follow before the first winter.

Storage work across South Dakota’s regions

Storage work in South Dakota follows the shape of its industry map. Sioux Falls and the I-29 corridor need food-grade process vessels, sanitation water, fuel and chemical storage for packing and food plants. Brookings, Watertown, Milbank and Lake Norden need milk, whey and brine silos and CIP systems for the dairy belt. Aberdeen, Huron, Mitchell and the James River valley carry most of the ethanol and oilseed storage, from denatured alcohol to process water. Rapid City and the Black Hills need fuel, water and process solution storage for mining, utilities and institutions, and Pierre’s government and institutional buildings run fuel and water storage of their own. Paul Industries builds for each region to the same standard and the same DANR file.

How much does tank fabrication in South Dakota cost?

Tank fabrication in South Dakota costs what the volume, material, construction standard, finish and site work make it cost, with the regulated-tank steps adding engineering and lead time rather than large fees. Stainless and sanitary finishes cost more than carbon steel; field erection costs more per job but less per gallon at large volumes; containment, foundations, cathodic protection and overfill alarms add substantially to a small fuel installation. Insulation, cladding and heat tracing add to every outdoor installation in this climate.

The contract side has two South Dakota items. Installed storage, with its foundations, counts as a realty improvement, so the state’s 2 percent contractor’s excise tax in SDCL 10-46A-1 is part of the installed price; and pump houses, loading shelters and enclosures are designed to the 2024 edition of the International Building Code, which SDCL 11-10-5 and 11-10-6 now name for non-residential work. Paul Industries gives a budget price from comparable work once the volume, product and location are known, and a firm price once the design is set.

Who fabricates tanks in South Dakota?

Paul Industries fabricates tanks in South Dakota: API 650 and UL 142 storage tanks for fuel, ethanol and chemicals, sanitary stainless silos and process tanks for dairy and food plants, process water and stillage tanks for ethanol plants, and water and fire storage. The same contract covers design, the DANR notification and plan package, containment, foundations, setting, piping, cathodic protection, testing and the certification-of-compliance records. Paul Industries is headquartered at 256 Shore Drive, Kilmarnock, Virginia, and accepts tank projects across South Dakota, from Sioux Falls and Brookings to Aberdeen, Huron and Rapid City.

Connected work comes under the same contract: process piping in South Dakota from the tank to the process, pressure vessel fabrication in South Dakota where the duty is pressurized, industrial welding services in South Dakota for repairs and modifications, boiler repair in South Dakota where tanks serve the steam plant, and heat tracing for outdoor nozzles and lines. Paul Industries also designs process tanks with agitators, jackets and instruments. The South Dakota page and the Midwest page cover the wider region.

Storage and process tanks from Paul Industries for South Dakota

Paul Industries builds South Dakota tanks to the standard it applies in its headquarters state, described on the tank fabrication in Virginia page, and under neighboring rules such as those on the Wisconsin tank fabrication page: the right construction code for the product, containment and overfill protection designed in, documented welds and tests, and a records package that answers the state’s forms. Buyers choose a supply-only tank, a design-build package or complete installation. Send the product, volume, location, any existing permits and the date the tank must be in service, and request a quote for tank fabrication in South Dakota.

Standards referenced: SDCL 34A-2-98 to 34A-2-101 · ARSD chapter 74:56:03 (aboveground stationary storage tanks) · ARSD chapter 74:56:01 (underground storage tanks) · 40 CFR Part 280 · 40 CFR Part 112 (SPCC) · NFPA 30 and NFPA 30A · API 650 · API 620 · API 653 · UL 142 · AWWA D100 and D103 · 3-A Sanitary Standards · ASME BPE · SDCL 11-10-5 and 11-10-6 (2024 International Building Code)

Frequently asked questions

Who builds custom process and storage tanks for Sioux Falls plants?

Paul Industries builds custom process and storage tanks for Sioux Falls plants, including stainless tanks for food and packing operations, CIP and hot water tanks, UL 142 fuel tanks and chemical storage. Each regulated tank is taken through DANR notification and plan approval before installation, and every tank is delivered with test records and drawings. Tanks can be supplied alone or installed with foundations, piping and controls.

Does Paul Industries build milk and whey silos for dairies in Brookings, Milbank and Lake Norden?

Paul Industries builds insulated stainless milk and whey silos and process tanks for dairy and cheese plants in Brookings, Milbank, Lake Norden and across eastern South Dakota. Silos are designed to 3-A Sanitary Standards with drainable bottoms, spray devices and sanitary manways, and outdoor units get sealed insulation and heated outlet enclosures for winter. Expansions are planned so new silos tie into the existing CIP system.

Who fabricates ethanol and denaturant storage tanks near Aberdeen, Huron and Watertown?

Paul Industries fabricates ethanol, denaturant, process water and stillage tanks for plants near Aberdeen, Huron, Watertown and across northeastern South Dakota. Denatured ethanol tanks are built to API 650 with internal floating roofs, overfill alarms and containment sized to 110 percent of the largest tank, and the DANR notification and plan package goes in at least 30 days before installation.

Does a generator fuel tank in South Dakota fall under the state AST rules?

A generator day tank or base tank that stores fuel for use on the premises where it sits falls outside South Dakota’s aboveground storage tank definition under SDCL 34A-2-100, which excludes tanks storing heating oil or motor fuel for consumptive use on site. The facility may still need an SPCC plan under 40 CFR 112 if it stores more than 1,320 gallons of oil aboveground. Paul Industries reviews the whole site’s storage before the tank is ordered.

How far ahead must DANR be notified before a new aboveground tank is installed?

DANR must be notified at least 30 days before a regulated aboveground tank is installed, under ARSD 74:56:03:02, and the department must approve the plans and specifications before installation begins. Containment plans have their own 30-day submission requirement under 74:56:03:11. Paul Industries submits the notification and plan package during design so approval arrives with the tank.

What must the certification of compliance cover for a South Dakota AST?

The South Dakota certification of compliance under ARSD 74:56:03:03 covers installation, any upgrade of an existing system, secondary containment, release detection and cathodic protection where it applies, and the owner must have the installer certify on the form that the methods comply. Changes to the information are reported to DANR. Paul Industries fills its part of the form from the installation records and gives the owner the supporting documents.

Is a tank under 25,000 gallons exempt from internal inspection in South Dakota?

A regulated aboveground tank of 25,000 gallons or less is exempt from South Dakota’s internal inspection requirement under ARSD 74:56:03:05. The routine inspections in 74:56:03:17 still apply: inventory measurements, monthly reconciliation and twice-yearly checks of overfill devices, gauges, valves, release detection and cathodic protection. Paul Industries builds smaller tanks with gauging and alarms that make those checks quick.

What tank construction standards does South Dakota accept for regulated tanks?

South Dakota’s AST rules accept tanks designed and built to a code of practice from a nationally recognized association or testing laboratory, naming UL 142 for construction and API 650 and UL 142 for installation, plus similar methods the department approves, all in substantial conformity with NFPA 30. Paul Industries builds UL 142 tanks for smaller fuel and chemical service and API 650 tanks for bulk storage, and documents the standard on the nameplate and drawings.

How should a South Dakota tank be protected against winter?

A South Dakota outdoor tank is protected against winter with insulation and sealed cladding where the product must stay liquid or cold, heat tracing on nozzles, drains, sample points and level instruments, heated enclosures for valves, vents and relief devices designed so ice cannot block them, and containment drains that stay closed and are checked before release. Paul Industries designs those details into the tank rather than adding them after the first freeze.

Can an existing tank be moved to a new South Dakota site?

An existing tank can be moved to a new South Dakota site when an evaluation of its shell, bottom, nozzles and nameplate supports continued service. A regulated tank at its new location goes through notification, plan approval, installation testing and the certification of compliance as a new installation would. Paul Industries inspects candidate tanks before purchase and quotes a new tank alongside when the evaluation is doubtful.

When does a South Dakota tank that is out of service have to be closed?

A South Dakota aboveground tank removed from service for longer than 24 months must be permanently closed under ARSD 74:56:03:28. Owners who expect to restart a tank plan its return before that point, or close it properly and record the closure with DANR. Paul Industries cleans, evaluates and either returns tanks to service with repairs and testing or removes them and supplies a replacement.

What does custom stainless steel tank fabrication cost for a South Dakota dairy?

Custom stainless steel tank fabrication for a South Dakota dairy is priced from the volume, alloy, interior finish, insulation and cladding, agitation, spray devices, instruments and the work to set and connect the tank. Silos for outdoor service add insulation, cladding and heated enclosures. Paul Industries gives a budget figure from comparable tanks first and a firm price once the design and connections are fixed.

Does Paul Industries handle tank work at mines and plants around Rapid City?

Paul Industries handles tank work around Rapid City and the Black Hills, including fuel, water, process solution and chemical tanks for mining, utilities and industrial plants. Regulated fuel and chemical tanks follow the same DANR notification, containment and inspection rules as elsewhere in the state, and process solution tanks are built to the chemistry and temperature of the service.

What is the difference between a flow-through process tank and a regulated storage tank in South Dakota?

A flow-through process tank in South Dakota is a tank that forms part of a process, with product passing through it, and both SDCL 34A-2-98 and 34A-2-100 exclude it from the storage tank definitions. A tank that accumulates a regulated substance for storage or dispensing is a regulated storage tank. The line matters for notification, containment and inspection, so Paul Industries confirms the classification with the plant before design.

Do bulk fuel tanks at South Dakota plants need overfill alarms?

Overfill control is required on all regulated aboveground tank systems in South Dakota under ARSD 74:56:03:13, and the owner must ensure the tank can hold each delivery. The rule accepts frequent gauging by personnel in contact with the supplier during transfer, a high-level detection device separate from the other gauging, with an alarm, or an approved equivalent. Paul Industries fits independent high-level alarms on the tanks it builds for fuel service.

What should a South Dakota plant send to get tank fabrication priced?

A South Dakota plant gets tank fabrication priced by sending the product and its temperature, the volume or dimensions, the preferred material, indoor or outdoor location, nozzle and instrument list, any agitation or heating needs, foundation and containment information, and whether the tank is regulated by DANR. Photos of the site help. Call 201-450-8280 or request a quote.

Planning a new or replacement tank in South Dakota?

Send the product, volume, location and the date the tank must be in service. Call 201-450-8280 or request a quote.