Paul Industries designs, builds and services ultrapure water systems in West Virginia for power and microgrid plants, chemical and materials producers, research laboratories, pharmaceutical and consumer products plants and hydrogen projects, from river or well intake through reverse osmosis, electrodeionization and polishing to the point of use. Many West Virginia plants draw feedwater from the Ohio, Kanawha or Monongahela rivers, whose dissolved minerals shift with rainfall, mine drainage and upstream industry, so the front end of a West Virginia system does more of the work than it would on a stable municipal supply. Paul Industries supplies skids, builds complete plants and loops, and maintains them, headquartered at 256 Shore Drive, Kilmarnock, Virginia.

Request a quote or call 201-450-8280

Headquarters 256 Shore Drive, Kilmarnock, Virginia
Feedwater rivers Ohio, Kanawha and Monongahela, plus Eastern Panhandle groundwater
Monongahela lesson Dissolved solids rose past EPA secondary limits in 2008, largely from mine drainage sulfate
Water use reporting 300,000 gallons or more in any 30 days registers with WV DEP
Industrial power 7.81 cents/kWh, US average 8.13 (EIA, 2024)
Reviewed November 2026

Where ultrapure water systems in West Virginia are put to work

Ultrapure water systems in West Virginia serve a different mix of users than in states with semiconductor fabs: the main users include boiler and turbine makeup, specialty chemical and materials production, research laboratory water, and, increasingly, the gas-fired power plants planned for data center campuses. Each user sets its own quality target, and the target sets the treatment train.

West Virginia ultrapure water users and what each one needs
UserWhere in West VirginiaWhat the water doesTypical train
Power plants and microgridsOhio and Kanawha river stations; planned data center microgrids in Mason County and elsewhereMakeup for high-pressure boilers, heat recovery steam generators and turbine injectionClarification or multimedia filters, RO, EDI or mixed-bed polishing, degassing
Chemical and materials plantsKanawha Valley, Mid-Ohio Valley, Northern PanhandleReaction and dilution water, catalyst and polymer work, steamRO with ion exchange polishing, sized for the product’s impurity limits
Research laboratoriesMorgantown federal and university labs, Huntington medical researchAnalytical work, cell culture, instrument feedCentral RO and storage with Type I polishing at the bench or a polished loop
Pharmaceutical and consumer products plantsMorgantown, Charleston, the Eastern PanhandleFormulation, cleaning and feed to Purified Water generationRO and EDI feeding a compendial system, or a dedicated ultrapure loop
Hydrogen electrolysisProjects associated with the Appalachian regional hydrogen hubElectrolyzer stack feedRO, EDI and polishing to the stack maker’s limit

These are market facts about where demand sits. The Kanawha Valley has hosted chemical manufacturing for many decades, including the Chemours plant at Belle, which makes industrial, agricultural and biochemical products and intermediates. The National Energy Technology Laboratory runs one of its three research sites in Morgantown. Procter & Gamble broke ground on its Tabler Station consumer products plant in Berkeley County in 2015. Morgantown was also home for decades to the Mylan generic drug plant, which Viatris closed in 2021.

How do West Virginia rivers change an ultrapure water treatment train?

West Virginia rivers change an ultrapure water treatment train by loading it with dissolved minerals that rise and fall far more than a municipal supply’s, and the sharpest example is the Monongahela, whose dissolved solids climbed above EPA’s secondary drinking water limit in late summer 2008. West Virginia University’s Water Research Institute identified treated mine drainage carrying calcium, sodium and sulfate as the controlling factor in that rise, ions that ordinary mine water treatment does not remove, while oil and gas activity adds chloride and bromide to the watershed. Since a voluntary discharge management program began in January 2010, sulfate and dissolved solids in the Mon have met EPA standards, but the episode shows the range a reverse osmosis plant on that river has to be designed for.

West Virginia feedwater sources and how each shapes an ultrapure water plant
SourceMain concernEffect on the plantDesign response
Monongahela River (Morgantown, Fairmont)Sulfate, calcium and sodium from mine drainage; chloride and bromide in some periodsCalcium sulfate scaling in the RO concentrate; higher ion load on polishingRecovery set for high-sulfate periods, antiscalant dosing, concentrate saturation monitoring
Kanawha River (Charleston, the Kanawha Valley)Industrial and municipal discharges upstream, seasonal organics and turbidityOrganic fouling of membranes; TOC carried toward the loopCoagulation and filtration ahead of RO, organics removal, intake monitoring
Ohio River (Huntington, Parkersburg, Wheeling)Large river with high suspended solids in flood periods and seasonal temperature swingsFilter loading and membrane flux changes with water temperatureClarifier or ultrafiltration pretreatment, temperature-compensated RO design
Municipal supply on river waterChlorine or chloramine residual plus the river’s own mineralsOxidant damage to polyamide membranesCarbon or bisulfite dechlorination, ammonia handling where chloramine is used
Eastern Panhandle wellsHard, carbonate-rich groundwater from the limestone valleyCalcium carbonate scaling, high hardness loadSoftening or acid and antiscalant control ahead of RO

Why sulfate sets RO recovery on northern West Virginia water

Sulfate sets reverse osmosis recovery on northern West Virginia water because calcium sulfate is one of the sparingly soluble salts that concentrate in the reject stream as recovery rises. An RO stage that recovers 75 percent of its feed concentrates the dissolved salts in the remaining quarter roughly fourfold, and when calcium and sulfate together pass their solubility limit, gypsum scale forms on the last membranes in the array. Antiscalants extend that limit, but the design has to hold during the worst month, not the average one, so Paul Industries sets recovery from the high end of the source data and fits monitoring that warns the operator before the concentrate reaches saturation.

The downstream stages feel the same swings. A higher ion load leaving the RO means more work for electrodeionization or mixed-bed polishing, shorter resin life, and more frequent regenerations or cartridge changes. Bromide and chloride are small, mobile ions, and the RO passes a measurable fraction of them, so the polishing stage is sized with margin for them.

Ultrapure water vs RO water: which grade does a West Virginia process need?

Ultrapure water vs RO water is the first question for any West Virginia project, because reverse osmosis permeate alone suits many uses at a fraction of the cost, and ultrapure polishing earns its place where the process needs it. RO typically removes the large majority of dissolved salts, leaving water good enough for cooling makeup, rinsing and feed to further treatment. Ultrapure water goes on through electrodeionization or ion exchange, degassing, ultraviolet treatment and fine filtration to reach resistivity near 18 megohm-centimeters with organics, particles and silica held to the user’s limits.

Water grades and where each one fits in West Virginia plants
GradeHow it is madeTypical West Virginia use
Softened or filtered waterSoftening, filtration, dechlorinationCooling tower makeup, low-pressure boiler feed, washdown
RO permeatePretreatment plus single or double pass ROProcess rinse, feed to polishing, humidification
Demineralized waterRO plus EDI or mixed-bed ion exchangeHigh-pressure boiler and heat recovery steam generator makeup, chemical production
USP Purified Water and WFICompendial systems built and validated to the monographsPharmaceutical formulation and cleaning
Ultrapure waterRO, EDI, polishing ion exchange, degassing, UV and final filtration in a recirculating loopResearch labs, electrolyzers, analytical work, specialty materials

An ultrapure water system for a West Virginia site is often a hybrid. A plant may run one RO train feeding cooling makeup, a demineralized header for its boilers and a small polishing loop for its laboratory, with one pretreatment system serving all three. The high-purity and process water in West Virginia page covers the cooling and boiler side of river-supplied plants, and the industrial DI water systems page covers deionized water plants.

Demineralized water for West Virginia’s microgrid power plants

Demineralized water for West Virginia’s microgrid power plants is a new and large ultrapure water market, because several data center campuses announced under the state’s 2025 microgrid law plan gas-fired generation on site, and combined-cycle plants need a continuous supply of high-purity makeup for their heat recovery steam generators. Turbines that use water injection or inlet fogging for power or emissions control add more demand. The campuses themselves describe closed-loop cooling, so their largest water-quality need may sit in the power plant rather than the data halls.

Boiler and turbine makers set strict limits on conductivity, silica and sodium in makeup water, because those impurities deposit on turbine blades and boiler tubes. A demineralization plant for a microgrid typically pairs RO with EDI or mixed beds, a degasifier and storage under a nitrogen or membrane blanket, with online conductivity, silica and sodium monitoring at the outlet. High-pressure steam boilers in West Virginia are inspected every year under W. Va. Code 21-3-7, and feedwater quality is part of what keeps them in safe service; the boiler repair in West Virginia page covers the boilers themselves, and the data center mechanical contractor in West Virginia page covers the rest of the campus mechanical work.

Hydrogen electrolysis and the Appalachian hub

Hydrogen electrolysis is a potential ultrapure water user in West Virginia through the Appalachian Regional Clean Hydrogen Hub, known as ARCH2, which DOE kept in its 2026 review of hydrogen hub awards while two western hubs lost funding. DOE has said the award is being modified and still has to clear its environmental review, so project timing remains open. Electrolyzer stacks, proton exchange membrane units especially, require high-purity feed water because dissolved ions shorten membrane and catalyst life, and each stack maker publishes its own limit.

An electrolyzer water plant resembles a small power plant demineralizer, with two differences: the plant consumes water continuously in proportion to hydrogen output, and the stacks reject heat that a closed cooling loop has to remove. Paul Industries builds the feed water system, the cooling loop and the interconnecting stainless piping as one package.

Type 1 ultrapure water systems for Morgantown and Huntington labs

Type 1 ultrapure water systems, meaning water meeting the ASTM D1193 Type I specification of 18 megohm-centimeters resistivity, serve the research laboratories in Morgantown and Huntington, from federal energy research to university medical and life science buildings. The ultrapure water West Virginia laboratories use comes either from bench-top polishers fed by a building RO loop or from a central polished loop that delivers it to every room.

For ultrapure water systems for biotech and life science labs, the decisive factors are microbial control and organics. Cell culture and molecular work care about endotoxin, bacteria and total organic carbon as much as resistivity, so the design uses continuous recirculation, ultraviolet treatment, sanitizable piping and ultrafiltration at the point of use where endotoxin limits apply. Paul Industries installs the central RO and storage, the distribution loop and the bench units, and provides the ultrapure water analysis at turnover: resistivity, TOC, bacteria and, where the lab needs it, endotoxin and particle counts.

Monitoring a West Virginia ultrapure plant when the source keeps changing

Monitoring a West Virginia ultrapure plant has to separate changes in the source from changes in the equipment, because a river that shifts in temperature, minerals and organics through the year makes raw instrument readings move even when the membranes and resin are healthy. The tool for that is normalization: RO permeate flow, salt passage and pressure drop are corrected to a reference temperature and feed concentration, so a falling normalized flow points to fouling or scale and a steady one shows the plant is simply responding to colder or saltier water.

A well-instrumented plant on river water carries feed conductivity, temperature, oxidation-reduction potential and silt density index ahead of the RO; normalized flow, salt passage and stage pressure drop across it; concentrate conductivity to watch the approach to gypsum saturation; and resistivity, total organic carbon and, for power service, silica, sodium and dissolved oxygen on the product. Paul Industries ties those readings into one trend display and sets alarm limits from the design basis, so operators see a cleaning need weeks before it becomes a quality excursion.

Sizing product storage and redundancy on a river-fed plant

Product storage and redundancy on a river-fed ultrapure plant are sized around the events that take a train offline: membrane cleaning, resin or EDI service, a pretreatment upset during a flood, and planned maintenance. A single RO train with enough treated-water storage to cover a cleaning cycle suits a laboratory or a modest process demand, while a power plant or a continuous chemical process that cannot stop usually runs two trains, each able to carry the full load, so one can be cleaned while the other produces.

Storage design matters as much as volume. Ultrapure product tanks are closed, with a nitrogen blanket or a hydrophobic vent filter to keep carbon dioxide and airborne particles out, and their outlets feed a loop that recirculates continuously so the water never stands. Demineralized makeup for boilers is often held in a larger tank sized to ride through a day or more of treatment outage, because the steam plant’s demand does not pause for a membrane cleaning. Paul Industries sets the train count and storage from the user’s tolerance for interruption and the source’s worst week, and shows the owner the trade between a second train and a larger tank in the proposal.

Replacing an older demineralizer at a West Virginia plant

Replacing an older demineralizer at a West Virginia plant usually means moving from two-bed or mixed-bed ion exchange, regenerated with bulk acid and caustic, to reverse osmosis followed by electrodeionization or service-exchange polishing. The change cuts the chemical deliveries, the regeneration waste and the neutralization load, and it steadies product quality, because an RO in front of the resin removes most of the ions the beds used to carry.

The conversion is staged so the plant never loses its supply. A typical sequence installs the RO skid and its storage beside the existing trains, runs the old beds on RO permeate for a period, which stretches their runs between regenerations, and then replaces the beds with EDI or polishers once the new system has proved itself. Existing tanks, pumps and piping are reused where their condition and materials allow, and Paul Industries surveys them before the design is fixed.

Startup and turnover sequence for a new ultrapure water system
StepWhat happensRecord handed over
Pressure testingEach piping system and vessel tested to its design codeTest reports with pressures, durations and witnesses
Flushing and cleaningConstruction debris and oils removed; stainless lines cleaned and passivatedCleaning and passivation reports
Membrane and resin loadingRO elements, EDI modules and polishing resin installed after cleaningSerial numbers and lot records
RO startupPressures, flows and recovery set; first normalized data takenBaseline normalization sheet
Loop rinse-up and sanitizationLoop recirculated until resistivity and TOC reach the target; sanitized and sampledRinse-up curves and microbial results
Analyzer calibration and performance runInstruments calibrated; plant run at design flow for the agreed periodCalibration certificates and performance test report

Permits and state rules for an ultrapure water plant in West Virginia

An ultrapure water plant in West Virginia touches four sets of state rules: water withdrawal reporting, the discharge of RO concentrate and regeneration waste, aboveground storage of regeneration and treatment chemicals, and the plumbing code for backflow protection and drains. None of them is unusual, but each has to be planned in the design rather than found during startup.

  • Withdrawal reporting. Facilities withdrawing 300,000 gallons or more in any 30-day period register with WV DEP as large quantity users and report each year. A plant drawing river water for RO and cooling often crosses that line.
  • Concentrate and regeneration waste. RO reject carries the river’s minerals at several times their feed concentration, and acid and caustic regeneration waste needs neutralization. Discharge goes to a permitted outfall or to a sewer under the utility’s pretreatment approval.
  • Chemical storage. Bulk acid, caustic and other liquids in aboveground tanks larger than 1,320 gallons fall under the Aboveground Storage Tank Act, W. Va. Code 22-30, with registration under 47 CSR 63. Tank design and secondary containment are covered on the tank fabrication in West Virginia page.
  • Plumbing code. Where the jurisdiction has adopted the State Building Code, 87 CSR 4, the 2018 International Plumbing Code governs backflow protection on the potable supply to the plant and air gaps at drains.

Ultrapure water cost in West Virginia: capital and operating drivers

Ultrapure water cost in West Virginia is set on the capital side by flow rate, final quality, the feedwater’s worst case, redundancy and the length and material of the distribution loop, and on the operating side by electricity, membranes, resin or EDI modules, chemicals, concentrate disposal and testing. A system on Monongahela water designed for high-sulfate periods carries more pretreatment and scale control than one on a softened municipal supply, and a polished loop in PVDF or electropolished stainless costs more per foot than the RO header that feeds it.

Electricity is a steady line. A treatment plant drawing 30 kilowatts around the clock, for RO high-pressure pumps, loop pumps, EDI and ultraviolet units, uses about 262,800 kilowatt-hours a year: about $20,500 at West Virginia’s 2024 industrial average of 7.81 cents (EIA), against about $21,400 at the 8.13 cent national figure. Higher RO recovery saves feed water and concentrate disposal, but on sulfate-rich water it costs antiscalant and cleaning, so Paul Industries prices recovery options side by side. Paul Industries offers a budget range from comparable systems early, then a firm price once flow, quality and source data are fixed.

Who builds ultrapure water systems in West Virginia?

Paul Industries builds ultrapure water systems in West Virginia for power and microgrid plants, chemical and materials producers, laboratories, pharmaceutical and consumer products plants and hydrogen projects. Paul Industries designs the treatment train from source data, fabricates and supplies RO, EDI and polishing skids, builds storage and distribution loops in PVDF, polypropylene or electropolished stainless, installs and starts up the system, and maintains it under a service agreement. Routes include supply of skids alone, design-build of a complete plant, or complete installation to an engineer’s design, with the process piping in West Virginia that ties the plant into the site.

From its headquarters at 256 Shore Drive in Kilmarnock, Virginia, Paul Industries, formerly based in northern New Jersey and then Pennsylvania, works as an East Coast contractor taking projects across West Virginia, in all 50 states and at plants outside the United States. For compendial systems that need qualification, see validation and commissioning in West Virginia. The ultrapure water systems in Virginia page covers the headquarters state, and the ultrapure water systems in Pennsylvania page covers sites downstream on the Monongahela and Ohio around Pittsburgh.

Ultrapure water work from Paul Industries in West Virginia

Paul Industries delivers each ultrapure water purification system in West Virginia with the records an operator needs: design basis and source water data, pressure and passivation records for metal piping, rinse-up and sanitization records for the loop, analyzer calibration, ultrapure water analysis results at turnover, and operating and maintenance manuals. Service agreements cover membrane cleaning, resin and cartridge replacement, analyzer checks and the final ultrapure water filtration system at each point of use. Send flow, quality target, source water analysis and site layout through request a quote. Paul Industries’ wider work in the state is on the West Virginia page.

Standards referenced: ASTM D1193 Standard Specification for Reagent Water · SEMI F63 Guide for Ultrapure Water Used in Semiconductor Processing · USP Purified Water and Water for Injection monographs · ASME BPE · Aboveground Storage Tank Act, W. Va. Code 22-30, and 47 CSR 63 · West Virginia State Building Code, 87 CSR 4 (2018 International Plumbing Code) · W. Va. Code 21-3-7, high-pressure steam boilers

Frequently asked questions

Does Paul Industries supply demineralized and ultrapure water plants to Kanawha Valley chemical sites?

Paul Industries builds ultrapure and demineralized water systems for chemical, materials and power plants across Charleston, Belle, Institute and the wider Kanawha Valley. Kanawha River supplies bring seasonal organics and turbidity, so those systems start with coagulation and filtration ahead of the RO and carry organics removal and intake monitoring. Call 201-450-8280 or request a quote with the flow and quality you need.

Does Paul Industries install ultrapure water systems in Morgantown and Fairmont?

Paul Industries installs ultrapure water systems in Morgantown, Fairmont and along the I-79 corridor for research laboratories, university buildings and industrial plants. Monongahela water there carries sulfate, calcium and sodium from mine drainage, so the RO recovery and antiscalant program are set from the high-sulfate end of the source data, and the polishing stage is sized for a heavier ion load.

Is there an ultrapure water contractor for Huntington, Parkersburg and the Ohio River plants?

Paul Industries designs and builds ultrapure and demineralized water plants for sites in Huntington, Parkersburg, the Mid-Ohio Valley and the Northern Panhandle. Ohio River water swings in suspended solids during floods and in temperature through the year, so those plants use clarifier or ultrafiltration pretreatment and RO designed for the coldest and warmest water they will see.

Does Paul Industries build water treatment for Eastern Panhandle plants on well water?

Paul Industries builds RO, EDI and polishing systems for plants in Martinsburg, Kearneysville and the rest of the Eastern Panhandle, where many sites draw hard, carbonate-rich groundwater from the limestone valley. Those systems soften or acid-dose ahead of the RO to control calcium carbonate scale, and wells are tested over several seasons before the design is fixed.

What water do the gas-fired microgrids on West Virginia data center campuses need?

Combined-cycle plants need demineralized makeup for their heat recovery steam generators, and turbines that use water injection or inlet fogging need more. The water is held to the boiler and turbine makers’ limits on conductivity, silica and sodium. Paul Industries builds RO and EDI or mixed-bed demineralizers with degassing, blanketed storage and online analyzers for that service, including for campuses in Mason County.

Why did the Monongahela River's dissolved solids rise in 2008?

West Virginia University’s Water Research Institute traced the 2008 rise largely to treated mine drainage carrying calcium, sodium and sulfate, which ordinary mine water treatment leaves in solution, with oil and gas activity contributing chloride and bromide. Discharge management since January 2010 has kept sulfate and dissolved solids within EPA standards, but RO plants on the river are still designed for that range.

How much RO recovery is realistic on Monongahela River water?

Achievable recovery depends on the calcium and sulfate in the feed during its worst month, the antiscalant used and the array design. Single-stage recovery is limited, and two-stage arrays reach higher figures when scale control keeps the concentrate below gypsum saturation. Paul Industries runs projection software against the full range of source data and sets recovery with margin, then monitors the concentrate in operation.

Does an ultrapure water plant in West Virginia need to register its water use?

Facilities withdrawing 300,000 gallons or more in any 30-day period register with WV DEP as large quantity users and report their use each year. A plant drawing river or well water for RO, cooling and process use often crosses that threshold, while a site buying water from a utility is a purchaser rather than a large quantity user. Paul Industries provides metering points so the reporting is straightforward.

Where does RO concentrate go at a West Virginia plant?

RO concentrate carries the feed water’s minerals at several times their original concentration and goes to a permitted outfall or to the sewer under the receiving utility’s pretreatment approval, often blended with other plant streams. Regeneration waste from ion exchange is neutralized first. Paul Industries designs the concentrate and waste piping, neutralization and sampling points to match the discharge permit the site holds.

Are acid and caustic tanks for an ultrapure water plant regulated in West Virginia?

Aboveground tanks holding more than 1,320 gallons of liquid, including bulk acid and caustic for regeneration and cleaning, fall under West Virginia’s 2014 tank law, W. Va. Code 22-30, and its registration rule, 47 CSR 63. Smaller day tanks still need secondary containment and compatible materials. Paul Industries supplies and installs the tanks, containment and chemical transfer piping.

Can one pretreatment train serve cooling, boilers and a lab loop at a West Virginia plant?

One pretreatment train can serve several water grades when it is sized for the combined flow and the strictest feed requirement. A common layout runs filtration and RO for the whole site, sends permeate to cooling makeup and a demineralizer for the boilers, and feeds a small polishing loop for the laboratory. Paul Industries designs the headers and storage so each grade stays isolated from the others.

What does a Type 1 ultrapure water system for a university lab building include?

A Type 1 system for a lab building usually includes a central RO with storage, a recirculating distribution loop with UV and continuous monitoring, and polishers at the benches that bring water to 18 megohm-centimeters with low TOC, plus ultrafiltration where endotoxin matters. Paul Industries installs the central plant, the loop and the bench units and tests resistivity, TOC and bacteria at each outlet before handover.

What water quality does a hydrogen electrolyzer in West Virginia need?

Electrolyzer stacks, proton exchange membrane units in particular, need high-purity feed water because dissolved ions shorten membrane and catalyst life; each stack maker publishes the resistivity and impurity limits for its product. A typical feed plant uses RO, EDI and polishing with continuous resistivity monitoring. Paul Industries builds the feed system and the stack cooling loop to the maker’s specification.

Which loop material suits an ultrapure water system at a West Virginia chemical plant?

Loop material follows the water grade, temperature, sanitization method and the plant’s chemical environment. PVDF suits high-purity cold loops and resists most plant chemicals, polypropylene serves lower grades at lower cost, and electropolished stainless suits hot-water sanitized and compendial loops. Paul Industries checks compatibility with the cleaning and sanitizing chemicals before choosing, and supports outdoor runs against winter freezing.

How is an ultrapure water system kept running through a cold West Virginia winter?

Cold feed water lowers RO flux, so plants on river water use feed heaters or temperature-compensated design to hold output in January. Outdoor tanks, piping and intake lines need heat tracing and insulation, and storage tanks are kept above freezing. Paul Industries includes winter operation in the design basis and checks heat tracing and insulation at each autumn service visit.

Which maintenance tasks keep a West Virginia ultrapure plant on specification?

A service agreement from Paul Industries covers membrane cleaning and replacement, resin and EDI module service, cartridge and final filter changes, UV lamp replacement, analyzer calibration and sanitization of the loop, with trend reports on recovery, salt passage and product quality. On river water, the agreement also tracks feed chemistry so antiscalant dose and recovery can be adjusted with the seasons.

What is the schedule for a new ultrapure water plant at a West Virginia site?

The schedule depends on flow, quality, how much is built on skids and the lead time of RO, EDI and analyzer equipment. Skid-built trains shorten field time because they arrive tested, while long stainless or PVDF loops through an occupied building take the most site time. Paul Industries sets the schedule after the design basis is fixed and orders long-lead items first.

What should a West Virginia site send to price an ultrapure water system?

Send the required flow and peak demand, the quality target or user specification, a source water analysis covering at least two seasons, the site layout and pipe run lengths to points of use, the utilities available and any existing equipment to reuse. Paul Industries replies with a budget figure based on similar plants and confirms a fixed price once the design basis is agreed.

Planning ultrapure water for a West Virginia site?

Send flow, quality target, a source water analysis and the site layout. Call 201-450-8280 or request a quote.