Paul Industries provides tank fabrication in West Virginia, designing, building, testing and installing carbon steel and stainless storage and process tanks for chemical plants, energy facilities, utilities, food producers and manufacturers to the state’s Aboveground Storage Tank Act and the Department of Environmental Protection’s rule, 47 CSR 63. West Virginia regulates aboveground storage more closely than most states because of a 2014 chemical spill into the Elk River at Charleston, and new storage there is designed from the start for registration, secondary containment, leak detection, corrosion protection and annual certification. Paul Industries builds the steel and the containment, overfill and monitoring equipment around it as one job.

Request a quote or call 201-450-8280

Headquarters 256 Shore Drive, Kilmarnock, Virginia
State tank law Aboveground Storage Tank Act, W. Va. Code 22-30 (2014)
Covered tanks Over 1,320 gallons of liquid, more than 90% above ground
DEP rule 47 CSR 63: design, containment, leak detection, corrosion
Annual certification Due to DEP on or before January 1
Reviewed November 2026

Why West Virginia regulates aboveground tanks so closely

West Virginia regulates aboveground tanks closely because of the January 9, 2014 Elk River spill, when crude MCHM leaked from a chemical storage facility in Charleston into the river upstream of a public water intake, leaving about 300,000 residents across nine counties under a water advisory. The Legislature responded the same year with Senate Bill 373, the Aboveground Storage Tank Act, now Chapter 22, Article 30 of the West Virginia Code, and the Department of Environmental Protection followed with the legislative rule 47 CSR 63.

The result is a program that reaches well beyond oil. The tank rules in neighboring Virginia and Maryland center on oil; West Virginia’s counts any fluid that is liquid at standard temperature and pressure, and sorts them by what they hold and how close they sit to drinking water. For a plant ordering new storage, the Act shapes the design as much as the process does: the bottom, the containment, the overfill protection and the corrosion protection are all decided against the rule before the first plate is cut.

West Virginia aboveground storage tank regulations: which tanks the Act covers

West Virginia aboveground storage tank regulations cover any device holding more than 1,320 gallons of a fluid that is liquid at standard temperature and pressure, built mainly of non-earthen materials, with more than 90 percent of its capacity above the ground. Mobile units count once they have stayed in one place for 365 days or more. The above ground storage tank definition in 22-30-3 then excludes a list of devices, among them process vessels, fire-water storage, food-grade vessels regulated under other law, pipelines, transformers and other electrical equipment, wastewater under active treatment and empty units held for sale.

Covered ASTs are then sorted into two levels. A Level 1 AST sits within a zone of critical concern or a source water protection area, holds a CERCLA hazardous substance or a chemical on the federal List of Lists at one percent or more, or holds 50,000 gallons or more regardless of contents or location. A Level 2 AST sits in a zone of peripheral concern and meets none of the Level 1 tests. The zones follow rivers and streams upstream of public surface water intakes: a zone of critical concern covers the corridor within about five hours of river flow above an intake, extending 1,000 feet from the banks of the main stream and 500 feet from tributaries, and the peripheral zone adds the next five hours.

Level 1 and Level 2 tanks under the West Virginia Aboveground Storage Tank Act and 47 CSR 63
RequirementLevel 1 tankLevel 2 tank
What sets the levelZone of critical concern or source water area; hazardous substance at 1% or more; or 50,000 gallons or moreZone of peripheral concern, with no Level 1 trigger
New constructionDouble-walled, double-bottomed, or set on a release prevention barrierBuilt to the general design rules of 47 CSR 63 section 8
Secondary containment checksVisual inspection at least every 14 daysChecked at the monthly inspection
New containment linerPermeability below 1 x 10-7 cm/s, verified at installationImpervious enough to hold a release for 72 hours
Qualified person inspectionInitially and every third yearInitially and every fifth year
Coating defect repairsWithin 12 months of discoveryWithin 24 months of discovery
Annual certification to DEPOn or before January 1On or before January 1

Sites along the Kanawha, Ohio and Monongahela rivers can sit upstream of public water intakes, so a site’s location on the DEP’s zone maps is one of the first questions on any new storage project. Paul Industries confirms the level with the owner before design, because a Level 1 classification changes the bottom construction, the containment liner and the inspection program.

How tank fabrication in West Virginia meets 47 CSR 63 section 8

Tank fabrication in West Virginia meets 47 CSR 63 section 8 by building each new AST to the manufacturer’s or fabricator’s instructions, the rule itself and the current industry codes from organizations such as API, ASME, NACE, NFPA, PEI, STI and UL, and by keeping documentation that proves it. In practice that means API 650 for welded field-erected storage tanks, UL 142 or STI standards for shop-built steel tanks, API 2000 and NFPA 30 for venting, and the plant’s own specification layered on top.

The rule sets testing before service. Shop-fabricated tanks are tightness tested, with pneumatic testing and soap solution on fittings and welds allowed, while field-erected tanks are hydrostatically tested. Any deficiency found is corrected before product goes in, and the owner keeps the test records. Foundations carry the full filled weight without movement or unacceptable settlement, drain away from the base, and resist flotation where the site floods. On karst ground, common in parts of eastern and southern West Virginia, the foundation is reviewed by an engineer or qualified installer and documented.

The rule also asks for baseline records. For new ASTs and their piping, thickness measurements and material certifications are kept for life, along with the manufacturer’s instructions, and major shell, roof or bottom work is inspected and tested before return to service. Paul Industries takes baseline thickness readings before the first fill and hands them over with the mill certificates, weld records and test results, so the first qualified inspection has a starting point to measure against.

Steel tank fabrication for Level 1 service adds one more decision: the bottom. A new Level 1 AST is double-walled, double-bottomed or set on a release prevention barrier, a liner or slab that keeps any bottom leak visible and out of the ground. Paul Industries designs each option with its leak detection method and prices them side by side, because the right answer depends on diameter, product and how the owner plans to inspect the floor.

Secondary containment, overfill and leak detection on a new West Virginia tank

Secondary containment on a new West Virginia tank holds the full capacity of the biggest single tank inside it, plus freeboard for rain, and the rule lists the 25-year, 24-hour storm among the factors used to size that freeboard. Manifolded tanks that drain into each other count as one. Containment holds a release for at least 72 hours, matches the chemistry of what is stored, and for new Level 1 systems meets a permeability limit of 1 x 10-7 centimeters per second. Stormwater is removed before it takes away 10 percent of the containment volume, and drain valves stay closed when not in use.

What 47 CSR 63 asks of a new aboveground storage tank system, and how it is built in
ElementRule requirementHow Paul Industries builds it
Overfill preventionGauge, high-level alarm with automatic cut-off or manned shutdown, or an approved deviceLevel instrument, independent high-level alarm and cut-off valve wired to the fill system
Secondary containmentBiggest tank’s volume plus freeboard; 72-hour holding; compatible materialsSteel or concrete dike sized from the storm basis, or a double-walled tank
Leak detectionAt least monthly, by a listed methodInterstitial monitoring on double-walled and double-bottomed tanks; visual access elsewhere
Spacing for visual checks3 feet between tanks and from dike walls, or an equivalent unobstructed viewLayout drawn to keep the spacing and access for inspection
VentingNormal and emergency venting to standards such as API 2000, NFPA 30 and UL 142Vents sized for fill rate, thermal breathing and fire exposure
FoundationFull filled weight, drainage, flotation protection, karst reviewRing wall or slab designed with the site’s geotechnical data
RecordsTests, baseline thickness and materials kept for the tank’s lifeOne handover package with drawings, tests and readings

A double-walled AST is its own secondary containment under the rule when the interstitial space and transfers are monitored continuously, though single-walled piping and ancillary equipment still need containment. For an aboveground storage tank system with several vessels, pumps and transfer piping, Paul Industries lays out the whole system, including the process piping in West Virginia between storage and process, so that containment, monitoring and isolation work together.

Corrosion protection on West Virginia tanks: cathodic protection, coatings and linings

Corrosion protection on West Virginia tanks is set by 47 CSR 63 section 9, which requires owners to keep corrosion from causing a release for as long as it is in service, using cathodic protection, coatings, linings or noncorrodible construction. A metal tank bottom in contact with soil is protected unless a corrosion expert finds the site too mild to cause a release.

Cathodic protection is designed by a corrosion expert holding NACE certification or equivalent, following API 651 for tank bottoms, and is tested within six months of installation, with bottoms in soil tested every year after. Impressed current rectifiers are checked every 60 days. Exterior coatings follow a recognized standard such as those of the Society for Protective Coatings, and defects are repaired within 12 months on a Level 1 AST or 24 months on a Level 2 AST. Interior linings follow API 652 or NACE guidance, run at least 18 inches up the shell from the bottom, and are inspected at least every ten years. Paul Industries specifies the coating system, lining and cathodic protection with the steel, so the corrosion design is part of the fabrication rather than an afterthought.

West Virginia tank registration and the certificate to operate

West Virginia tank registration is due before a new tank stores any fluid, filed by the owner or operator with the Department of Environmental Protection, and a tank placed into service after July 1, 2015 carries a registration fee of $20 per tank. Operating an unregistered AST, or one with unpaid fees, is unlawful under the Act. Registration lists ownership, location, installation date, construction type, capacity, age and contents.

The WVDEP aboveground storage tank program issues a certificate to operate for Level 1 and Level 2 tanks from that registration, renewed each year when the fee is paid, financial responsibility is maintained and the tank stays in compliance. Registrations and the annual certifications are filed online, and the West Virginia tank database built from them is how the Department tracks each unit’s level, inspections and status. Paul Industries supplies the construction, capacity and material data the owner needs for the registration form at handover.

How often should above ground storage tanks be inspected in West Virginia?

Above ground storage tanks in West Virginia are inspected on four cycles under 47 CSR 63: a monthly check by the owner, containment checks every 14 days for Level 1 tanks, a qualified person’s inspection initially and every third year for Level 1 or every fifth year for Level 2, and an annual certification to the Department due on or before January 1. The monthly check covers leak detection results, the exterior surface and coatings, ancillary equipment and overfill prevention, and records are kept for at least 12 months.

A qualified person under the Act is a registered professional engineer, someone working under a professional engineer’s direct supervision, an inspector holding API or STI tank inspection certification, or a person in another program the Secretary approves. Internal inspections follow API 653 or STI SP001, and a new tank’s first internal inspection falls within 20 years, or 30 years when it sits on a release prevention barrier; tanks of 30,000 gallons or less are exempt from that internal schedule when they meet the overfill and leak detection sections. An AST found unfit for service comes out of service at once and returns only after a fit-for-service evaluation, and malfunctioning equipment is repaired, replaced or removed within 30 days. Paul Industries repairs ASTs to clear those findings, from new bottoms and shell plates to nozzle and roof repairs, and tests them before they go back into service.

Stainless and process tanks that sit outside the AST program

Stainless and process tanks at West Virginia plants often sit outside the Aboveground Storage Tank Act, because the definition excludes process vessels and food-grade tanks regulated under other law. A mix tank, reactor feed tank or batch vessel that is part of a production process is designed to the plant’s process and sanitary standards rather than to 47 CSR 63, while the plant’s raw material and finished product storage usually falls inside it.

Stainless steel tank fabrication for those services follows the same discipline as any process equipment: material selection for the product and cleaning chemicals, polished or passivated finishes where hygiene matters, sloped bottoms and full drainage, and nozzles laid out for the agitator, instruments and spray devices. Paul Industries builds stainless process tanks with their sanitary process piping in West Virginia, and builds tanks that operate under pressure as code vessels through pressure vessel fabrication in West Virginia. The line between a storage tank, a process tank and a pressure vessel is settled on the data sheet before design begins.

Underground storage tanks in WV and replacing them above ground

Underground storage tanks in WV are regulated separately, under the Department of Environmental Protection’s rule 33 CSR 30 and the federal underground storage tank program, and the 2014 Act and 47 CSR 63 apply to tanks with more than 90 percent of their capacity above ground. Owners replacing an aging underground fuel tank with an aboveground one move from one program to the other, and the replacement arrives with Act registration, containment and inspection duties.

That move is often worth making. An aboveground tank can be inspected from the outside, leaks show up in containment rather than in soil, and a double-walled or shop-built tank with interstitial monitoring keeps the monthly checks simple. Paul Industries takes the old unit out of the fuel system, fabricates and sets the replacement with its containment and monitoring, connects the piping and tests the system before fuel is transferred.

Types of above ground storage tanks at West Virginia sites

The types of above ground storage tanks at West Virginia sites range from shop-built horizontal fuel tanks for generators and boilers to field-erected vertical tanks for chemicals, water and petroleum products, and each region of the state brings its own mix. Table 3 sets out the common ones.

Typical tanks by West Virginia region and how they are built
RegionTypical tanksConstruction notes
Charleston and the Kanawha ValleyChemical raw material and product storage, process tanksAlloy or lined construction, Level 1 bottoms near intakes, containment compatible with the chemical
Parkersburg, Huntington and the Ohio RiverChemical and polymer storage, terminal tanks, fuelField-erected API 650 tanks, flood and flotation design on riverfront sites
Morgantown, Fairmont and ClarksburgHospital and campus generator fuel, energy sector liquidsDouble-walled shop tanks, overfill alarms tied to fuel delivery
Wheeling, Weirton and the Northern PanhandleIndustrial process liquids, fuel, produced liquids from gas productionCarbon steel with coatings and cathodic protection, containment sized for storms
Martinsburg and the Eastern PanhandleManufacturing, distribution and data center fuel storageKarst foundation review, generator day tanks and bulk fuel
Beckley, Bluefield and the southern countiesFuel, water and treatment chemical tanks at plants and utilitiesShop-built tanks sized for mountain road delivery

What does tank fabrication cost in West Virginia?

Tank fabrication cost in West Virginia depends on capacity, material, shop-built or field-erected construction, the bottom design the tank’s level calls for, coatings and cathodic protection, containment, instruments and the foundation. Capacity sets the base, but the regulatory items often move the total more: a Level 1 double bottom or release prevention barrier, a low-permeability containment liner, an interstitial monitoring system and an independent overfill cut-off each add cost that storage outside the Act does without.

The state’s own fees are modest: $20 to register a tank placed in service after July 1, 2015, plus the annual fee that renews the certificate to operate. Delivery shapes the design as well. Shop-built units are limited by what fits on a truck over the route to site, so larger capacities move to field-erected construction, which brings site welding, a hydrostatic test with water supply and disposal, and a longer schedule. Paul Industries prices each route where both fit, with tank, containment, instruments, foundation and installation shown separately.

When tank fabrication companies are compared, the useful measure is what the price includes: design to the Act, containment and overfill equipment, coatings and cathodic protection, testing, baseline records and installation. Paul Industries quotes the complete system, so the price covers everything needed before the AST can lawfully hold product.

Who fabricates tanks in West Virginia?

Paul Industries fabricates tanks in West Virginia, designing and building carbon steel and stainless storage and process tanks, setting and testing them, and building the containment, overfill and monitoring equipment the Aboveground Storage Tank Act requires. Headquartered at 256 Shore Drive, Kilmarnock, Virginia, and formerly based in northern New Jersey and then Pennsylvania, Paul Industries is an East Coast contractor taking tank projects across West Virginia and in all 50 states.

Among tank fabricators serving the state, Paul Industries brings the vessel and its surroundings under one contract: the foundation, the steel, the coatings, the piping, the welding and the records. The national scope is on the tank fabrication page, and tanks for production lines are covered under process tanks. Owners with sites in the headquarters state compare West Virginia’s rules with tank fabrication in Virginia, and those with sites in the Mid-Atlantic compare them with tank fabrication in Maryland. Repairs and modifications use industrial welding services in West Virginia, existing units are emptied and cleaned through industrial tank cleaning, and boiler fuel and condensate storage ties into boiler repair in West Virginia.

Tanks from Paul Industries for West Virginia owners

Paul Industries designs, fabricates, supplies, installs, tests, repairs and maintains storage and process tanks for West Virginia plants, utilities and institutions, meeting the aboveground storage tank requirements of the Act and 47 CSR 63 from the first drawing. Three routes are offered: a supplied unit delivered to site, a supplied unit set and connected, or a design-build tank farm complete with foundations, containment, piping and controls. Other plant services in the state are listed on the West Virginia hub. Contents, capacity and the site’s location on the DEP zone maps are enough to begin; request a quote with them.

Standards referenced: W. Va. Code 22-30, Aboveground Storage Tank Act · 47 CSR 63, Aboveground Storage Tanks · 33 CSR 30, Underground Storage Tanks · API 650 · API 653 · API 651 · API 652 · API 2000 · UL 142 · STI SP001 · NFPA 30 · 40 CFR 112 SPCC

Frequently asked questions

Does Paul Industries fabricate chemical storage tanks in Charleston, South Charleston and Nitro?

Paul Industries designs, fabricates and installs chemical storage and process tanks for plants in Charleston and along the Kanawha Valley, with the containment, overfill protection and leak detection the Aboveground Storage Tank Act requires. A site inside a zone of critical concern builds to Level 1 standards whatever the tank stores. Call 201-450-8280 to discuss a project.

Does Paul Industries fabricate tanks for plants in Parkersburg, Huntington and along the Ohio River?

Yes. Paul Industries builds field-erected and shop-built tanks for chemical, polymer, terminal and manufacturing sites in Parkersburg, Huntington and the Ohio River corridor. Riverfront sites bring flood and flotation design into the foundation, and a site’s position relative to downstream intakes shapes the bottom and containment design.

Who builds fuel tanks for hospitals and data centers in Morgantown and the Eastern Panhandle?

Paul Industries fabricates and installs double-walled generator fuel tanks, day tanks and bulk fuel storage for hospitals, campuses, data centers and distribution sites in Morgantown, Martinsburg and the Eastern Panhandle. Each system includes overfill alarms, interstitial monitoring and the registration data the owner files with the Department of Environmental Protection.

Does a generator fuel tank under 1,320 gallons fall under the West Virginia Act?

The Act’s definition starts above 1,320 gallons, so a single tank at or below that size sits outside the state program, although its installation still follows the fire code and the manufacturer’s standard. Federal SPCC rules count aggregate oil storage on the site, so several small tanks together can still trigger a federal spill plan. Paul Industries sizes and documents fuel tanks with both thresholds in view.

What is a zone of critical concern for a West Virginia tank?

A zone of critical concern is the stream corridor above a public surface water intake within about five hours of river flow, extending 1,000 feet from the main stream’s banks and 500 feet from tributaries. A tank inside that zone is a Level 1 tank whatever it holds. The Department of Environmental Protection maps the zones, and Paul Industries checks the site’s location before design.

What does a release prevention barrier do on a Level 1 tank?

A release prevention barrier is a liner or impermeable layer under the tank bottom that keeps any bottom leak from reaching the soil and routes it to a point where it is seen. It is one of three options for a new Level 1 tank, alongside a double wall or a double bottom, and it extends the first internal inspection deadline from 20 to 30 years under 47 CSR 63.

Who can sign the annual certification for a West Virginia aboveground tank?

The certification is signed by the person who performed the evaluation, a responsible person the owner designates, or another person the Secretary names by rule. The evaluation itself is done by a registered professional engineer, someone under a professional engineer’s supervision, an inspector holding API or STI certification, or another approved program. Paul Industries supplies the repair records and test results that support it.

Can an existing tank be relocated within a West Virginia plant?

A relocated tank gets a new foundation designed for its full filled weight, a tightness or hydrostatic test before it holds product, updated registration with its new location, and, where it is metal on soil, cathodic protection appropriate to the new site. Paul Industries moves, resets, tests and documents relocated tanks so the registration and records stay current.

What happens to a West Virginia tank that is permanently closed?

A tank taken permanently out of service is emptied and cleaned, its closure follows section 11 of 47 CSR 63, and if it stays on site it is labeled with the closure date and the words Permanently Closed. Paul Industries cleans, disconnects and removes or labels closed tanks, and builds replacements where the storage is still needed.

Are produced water and condensate tanks at gas well sites covered by the Act?

The Act’s exclusions cover some oil and gas production equipment, such as liquid traps and gathering lines, and treat certain brine tanks differently by size and location, while larger storage at processing and compression sites is assessed against the Level 1 and Level 2 tests. Classification depends on the specific tank, its contents and location. Paul Industries confirms the classification with the operator before design.

What leak detection methods does 47 CSR 63 accept?

The rule lists visual inspection, automatic tank gauging, statistical inventory reconciliation, interstitial monitoring, soil vapor monitoring, volumetric or mass measurement, acoustic measurement and inventory control combined with tightness testing, with other methods by approval. Monitoring takes place at least once a month. Paul Industries builds in interstitial monitoring on double-walled and double-bottomed tanks because it gives a clear, continuous answer.

Should a West Virginia plant choose carbon steel or stainless for a chemical tank?

The choice depends on the chemical, its temperature and concentration, the cleaning regime and the life expected. Carbon steel with a lining or coating costs less up front for many chemicals but brings lining inspections at least every ten years under 47 CSR 63. Stainless or a higher alloy avoids the lining in many services. Paul Industries compares both on cost over the tank’s life.

How does karst ground affect a tank foundation in the Eastern Panhandle?

Karst ground, with limestone cavities and sinkholes, raises the risk of settlement or collapse under a heavy tank, so 47 CSR 63 requires a new tank foundation in karst terrain to be reviewed and documented by an engineer or qualified installer. Geotechnical investigation, grouting or a structural slab are typical answers. Paul Industries designs the foundation with the site’s geotechnical data before the tank is built.

How long does a field-erected tank take to build at a West Virginia site?

Schedule depends on diameter, height, material and weather. Plate is cut and formed off site while the foundation is built, then the bottom, shell and roof are erected and welded in place, followed by examination and a hydrostatic test. Winter weather in the mountains affects welding and testing, so outdoor work is sequenced around it. Paul Industries sets the schedule in the quotation.

Which details start a tank quotation for a West Virginia site?

Send the contents and their concentration and temperature, the capacity, any size limits on the site, the location and whether it falls within a zone of concern, the preferred material, the nozzle and instrument list, and whether containment, foundation and installation are included. Paul Industries returns a priced design with the tank level, construction route and schedule stated.

Can Paul Industries repair a tank bottom that fails a West Virginia inspection?

Yes. Paul Industries replaces floor plates, installs new bottoms with or without a release prevention barrier, repairs shell and nozzle welds and recoats or relines tanks found deficient at inspection. Major bottom or shell repairs are inspected and tested before the tank returns to service, and the records go to the owner for the certification file and the tank’s permanent history.

Planning a new or replacement tank in West Virginia?

Send the contents, capacity, site location and the containment and installation scope you need. Call 201-450-8280 or request a quote.