Paul Industries provides boiler repair in Tennessee for manufacturing plants, hospitals, distilleries, campuses and commercial buildings, working to T.C.A. 68-122 and the rules of the Tennessee Board of Boiler Rules. Paul Industries retubes, weld-repairs, rebuilds controls and burners, replaces safety valves and low-water cutoffs, and prepares boilers for state certificate inspections. Headquartered at 256 Shore Drive in Kilmarnock, Virginia, the company takes boiler work across all of Tennessee, from Memphis to the Tri-Cities.

Request a quote or call 201-450-8280

Headquarters 256 Shore Drive, Kilmarnock, Virginia
State law T.C.A. 68-122, Department of Labor and Workforce Development
Heating boilers Internal and external every two years (BI 22-03)
Power boilers Internal yearly, external six months later (BC 22-02)
Certificate Up to 24 months power, 26 months heating (T.C.A. 68-122-111)
Reviewed November 2026

What does boiler repair in Tennessee involve under T.C.A. 68-122?

Boiler repair in Tennessee involves restoring a boiler’s pressure parts, controls and safety devices so that it passes the state’s certificate inspection and keeps its certificate, under a law that reaches further than most owners expect. Tennessee’s definition of a boiler includes unfired pressure vessels, meaning vessels pressurized from an external source or by indirect heat (T.C.A. 68-122-102), so steam-heated kettles, receivers and heat-exchanger shells sit in the same program as the boiler that feeds them.

The Board of Boiler Rules, attached to the Department of Labor and Workforce Development, writes the rules in Chapter 0800-03-03. They adopt the latest ASME Boiler and Pressure Vessel Code, the latest National Board Inspection Code (NBIC), ASME CSD-1 for controls and NFPA 85 for large combustion systems. A Tennessee repair is therefore an NBIC repair with a state layer on top: who must be consulted, when the inspector returns, and which certificate the boiler runs under afterward. The national picture of faults and repair methods sits on the boiler repair page; this page covers what changes once the boiler sits in Tennessee.

Tennessee boiler inspection requirements by boiler type

Tennessee boiler inspection requirements depend on the boiler class: power boilers are opened every year, low-pressure heating boilers and corrosive-service unfired vessels every two years, and noncorrosive unfired vessels on an external schedule the Board sets (T.C.A. 68-122-110). The inspection itself is made by the state’s Chief or Deputy Inspectors or by a Special Inspector employed by the boiler’s insurer, and the report is due to the Chief Inspector within 30 days.

Tennessee inspection intervals, certificate terms and state fees by boiler class
Boiler classInspection requiredCertificate valid forState certificate fee
Power boiler (steam above 15 psig)Internal and external yearly while shut down; external under pressure about six months after each internal (BC 22-02)Up to 24 months$50
Low-pressure steam or hot water heating boilerInternal and external every two years where construction permits; internal 60 days to 12 months after the external (BI 22-03)Up to 26 months$60
Hot water supply boiler and larger potable heatersRegistered and inspected; potable heaters of 100,000 to 199,999 Btu/hr are also registered, inspected and certificatedAs stated on the certificatePer Rule 0800-03-03-.14
Unfired vessel subject to internal corrosionInternal and external every two years, longer at the Board’s discretionUp to 26 months$60
Unfired vessel with noncorrosive contentsExternal at intervals the Board sets; internal waived when contents are known to be noncorrosiveUp to 26 months$60

A two-month grace period may run past the twelve-month mark between internals or between externals (T.C.A. 68-122-110(b)), and certificate inspections are scheduled within two months either side of the certificate’s expiration date (Rule 0800-03-03-.05). Operating a boiler without a valid certificate, or above the pressure printed on it, is a Class C misdemeanor for the owner, user or operator, and each day counts as a separate offense (T.C.A. 68-122-112).

Why did BI 22-03 change the schedule for low-pressure heating boilers?

Board Interpretation BI 22-03, approved on June 15, 2022, made internal inspection of low-pressure heating boilers a fixed biennial requirement instead of something done at the inspector’s discretion. The statute had long said that heating boilers are inspected internally and externally every two years where construction permits, but in practice the internal was often skipped. The Board’s reply settled it: the external inspection is the certificate inspection, and the internal follows no sooner than 60 days and no later than 12 months after that external.

For a hospital, school district, hotel or office owner, the ruling means a heating plant now needs a planned cold outage every other year. Tennessee heating boilers are often idle or lightly loaded from late spring to early autumn, which makes summer the natural window for the internal. Paul Industries uses that window to open the boiler for the inspector, clean the fireside and waterside, replace gaskets and handhole seats, and repair whatever the inspection turns up, so the boiler returns to service before the heating season instead of during it.

Which boilers sit outside the Tennessee boiler law?

The Tennessee boiler law leaves out several groups of equipment entirely, and exempts several more from inspection and certificate requirements (T.C.A. 68-122-105). Knowing which group a unit falls into tells the owner whether a repair needs the state inspector at all.

  • Outside the Act: boilers under federal control, boilers that generate electricity under contract with the Tennessee Valley Authority, unfired vessels of 5 cubic feet or less, unfired vessels designed for 15 psig or less, vessels holding liquefied petroleum gas, vessels built for interstate shipment, vessels inside a medical or dental autoclave, and miniature boilers built into FDA-regulated medical devices.
  • Exempt from inspection and certificates: boilers on farms used solely for agriculture, steam heating boilers at 15 psig or less and hot water heating boilers at 30 psig or less in private homes or apartment houses of fewer than six families, and domestic water supply vessels at or below 200 degrees Fahrenheit.

The federal exemption matters in East Tennessee, where Oak Ridge National Laboratory and other federal sites operate their own programs, while privately owned plants in the same county remain under the state. The Act also leaves room for municipal boiler ordinances that substantially conform to the ASME Code, and it never excuses an owner from the municipal building permit for erecting a boiler. Those exemptions never change the engineering: an exempt boiler still gets an NBIC-quality repair when Paul Industries does the work.

How does a Tennessee boiler repair get authorized and accepted?

A Tennessee boiler repair is authorized by the inspector of the Authorized Inspection Agency responsible for that boiler’s in-service inspection, who is consulted before welding starts, reviews the completed work, and signs the National Board R forms (Rule 0800-03-03-.07). For a boiler covered by boiler insurance that inspector is the insurer’s Special Inspector; for an uninsured boiler it is a state Deputy Inspector. The same rule states that welded repairs and alterations are made under a National Board R Certificate of Authorization together with a state license issued under the Boiler Erectors and Repairers Act (T.C.A. 68-122-202).

Paul Industries brings the inspector in at the planning stage, with the repair method, weld procedure, materials and examination plan written down, so the inspector’s hold points are agreed before the boiler is opened. The finished repair is documented on Form R-1, an alteration on Form R-2, and a rerate counts as an alteration in Tennessee even without welding, because the rules treat a non-physical increase in pressure or temperature as one.

Routine repairs after the 2025 revision of BC 12-18

Tennessee accepts NBIC routine repairs under Board Case BC 12-18, whose answer was revised on September 10, 2025 to allow them with post-repair examination or testing at the repair inspector’s discretion. Routine repairs skip the inspector’s in-process involvement, but they still go on Form R-1 marked “Routine Repair”, and the Board’s June 2025 revision keeps the nameplate and stamping requirements in force for them.

How common boiler repairs are handled under Tennessee rules
RepairTennessee routeRecord the owner keeps
Tube, valve, fitting or pipe replacement, NPS 5 and smaller, no PWHT or non-visual NDERoutine repair under BC 12-18Form R-1 marked “Routine Repair”; stamping still applied
Weld buildup of wasted shell or head areasRoutine when within 100 square inches and 25 percent of wall or 1/2 inch, whichever is less; otherwise a full repairForm R-1 with thickness readings
Seal welding of a mechanical jointRoutine when the weld carries no strength and needs no PWHTForm R-1
Furnace, tubesheet or drum repairFull NBIC repair with inspector hold pointsForm R-1, weld procedure and welder records, NDE reports
Rerate or added nozzleAlteration, accepted by the inspectorForm R-2 and revised nameplate data
Safety valve rebuild or resetNational Board VR certificate holder or an owner-user organization the Chief Inspector approvesValve repair nameplate and test record

Preparing a boiler for a Tennessee state boiler inspection

A Tennessee state boiler inspection that opens the boiler needs the unit drained, washed, cooled and isolated, and the inspection date is set at least seven days after the owner is notified (Rule 0800-03-03-.05). The rule lists the preparation: manhole and handhole plates off, washout plugs and water column plugs removed as the inspector requires, furnace and combustion chambers cooled and cleaned, insulation or brickwork removed where needed, the pressure gauge pulled for testing, and steam-stop and blowoff valves on common headers closed, tagged and preferably padlocked with the drains between them open.

Before anyone enters a drum, plant staff confirm that inlet and outlet stops are closed and tagged or the lines blanked, and test the atmosphere for oxygen between 19.5 and 23.5 percent and for toxic gas. An inspector may decline a boiler that is poorly prepared, withhold the certificate and still charge the inspection. Paul Industries prepares boilers to that list as part of the repair scope, so the inspection, the repair and the reassembly happen in one outage.

How often should boilers be inspected beyond the legal minimum? Plants with poor feedwater control, frequent cycling or a history of tube failures benefit from an extra waterside look at the midpoint between state internals, and Paul Industries pairs that with boiler water treatment review because deposits and oxygen pitting cause most of the tube work it sees.

Pressure tests, safety valves and controls after the repair

A pressure test on a Tennessee boiler is limited to one and one-half times the maximum allowable working pressure, with test water no colder than 70 degrees Fahrenheit and no hotter than 120 degrees during the inspection, and with each safety valve removed or held by a test clamp rather than by screwing down its spring (Rule 0800-03-03-.05). A tightness test uses normal operating pressure but need not exceed the lowest safety valve setting.

Controls carry their own Tennessee requirements. Every automatically fired boiler has at least one low-water fuel cutoff meeting ASME CSD-1, and boilers installed between 400,000 and 12,500,000 Btu/hr meet all of CSD-1, with NFPA 85 added at 12,500,000 Btu/hr and above (Rules .04 and .08). Blowdown that enters a sanitary sewer passes through blowoff equipment that brings it to 150 degrees Fahrenheit or less and 5 psig or less. When Paul Industries replaces a cutoff, flame safeguard or fuel train, the work is set up and function-tested to CSD-1 and the test is recorded for the next inspector.

Tennessee boiler variance requests and attendant rules for continuous plants

A Tennessee boiler variance lets the Board of Boiler Rules approve longer intervals between internal inspections for a boiler that meets the Board’s checklist, with the request filed at least 45 days before the Board’s next meeting (T.C.A. 68-122-110(f)). A boiler running under a variance gets an external inspection under pressure about every six months, and a failed external means shutdown, an internal inspection and a rescinded variance.

Attendance is the other rule continuous plants plan around. Rule 0800-03-03-.08 requires a qualified attendant to check any power boiler of 5 horsepower or 50 square feet of heating surface, and Board Case BC 22-03 (June 2022) moved the check interval from 20 minutes to once an hour, following National Board recommendations,with a log kept of every hourly check. Plants that seek a Board variance from the attendant rule have 180 days after a contingent approval to tell the Chief Boiler Inspector the boiler is ready for its acceptance inspection, with one extension of up to 180 days, or the variance is cancelled (BC 24-02). A repair that changes controls or alarms should leave the attendant’s log sheet and the control narrative in agreement, and Paul Industries updates both at turnover.

How do Tennessee rules treat older and nonstandard power boilers?

Tennessee’s rules for existing power boilers set an age limit of 30 years for a nonstandard boiler, meaning one built without ASME and National Board stamping, unless it qualifies for continued service (Rule 0800-03-03-.10). A nonstandard boiler without lap-riveted longitudinal joints keeps running as long as it shows no distress or leakage in a pressure test at up to 90 percent of the lowest relief valve setting, held at least 30 minutes with water between 60 and 120 degrees Fahrenheit. Lap-riveted boilers above 50 psig are limited to 20 years, and once removed from their setting they return only at 15 psig or less.

The same rule fixes several limits that decide whether an old boiler is worth repairing. Watertube boilers with cast iron or malleable iron headers or cast iron mud drums are capped at 160 psig, cast iron boilers other than hot water units at 15 psig, weighted-lever safety valves and valves with cast iron seats or disks are prohibited, and a boiler with more than 500 square feet of water-heating surface carries at least two safety valves. Standard boilers keep the pressure of their original ASME construction, and their service life is judged on each internal inspection. Paul Industries reviews those limits with the owner before quoting a major repair on an older unit, so money goes into a boiler that will keep its certificate.

Where Tennessee boilers carry the heaviest duty

Tennessee boilers carry the heaviest duty in chemical, battery, distilling and food plants, where steam is a process input rather than a comfort load. The state’s Department of Economic and Community Development reports more than 870 food and beverage companies in Tennessee and calls the state the top whiskey exporter in the country, and chemicals anchor the northeast corner, where Eastman has its headquarters and largest manufacturing site in Kingsport. These plants are named only as market facts.

Tennessee regions, boiler duty and the repair emphasis that follows
RegionTypical boiler dutyRepair emphasis
Tri-Cities and KingsportLarge watertube power boilers and waste heat units serving chemical processesAnnual internals at planned outages, variance planning, tube and drum repairs under full NBIC procedures
Knoxville, Oak Ridge and East TennesseeCampus and hospital heating plants, private industrial plants beside federal sitesBI 22-03 internals in summer, burner and control upgrades
ChattanoogaIndustrial steam for manufacturing and food plantsRetubing, refractory, feedwater and deaerator repairs
Nashville, Murfreesboro and Middle TennesseeHospital sterilizer steam, battery and vehicle plant utilities around Spring HillRedundant boiler staging, CSD-1 control work, clean steam interfaces
Lynchburg and TullahomaDistillery steam for mash cooking and stillsRepairs between production campaigns, condensate return and steam trap work
Memphis, Shelby County and JacksonFood processing, distribution campuses and hospital plantsHot water and low-pressure steam internals, blowoff equipment, firetube retubing

Repairing an industrial boiler: Chattanooga, TN and Tri-Cities outages

Industrial boiler repairs in Chattanooga and the Tri-Cities are usually scheduled into plant outages that also cover piping, vessels and steam traps, which is where combining scopes saves the most downtime. Paul Industries plans the boiler repair alongside the process piping in Tennessee and pressure vessel fabrication in Tennessee scopes that share the same outage, and repairs steam traps and condensate return while the header is cold.

Replacing a boiler: the Tennessee boiler permit and installation rules

A Tennessee boiler permit, formally the installation permit, is issued by the Chief Inspector before any installation work begins, on an application that includes boiler room layout drawings, the Manufacturer’s Data Report, a copy of any municipal building permit and the controls and safety devices section (Rule 0800-03-03-.04). The permit lasts twelve months. A Deputy Inspector inspects the new boiler before it goes into service, and the state attaches its registration tag beside the code stamping.

Several Tennessee installation rules shape a replacement: at least 3 feet of clearance above the boiler and on all sides, 5 feet in front of any manhole, two remote exits from a boiler room larger than 500 square feet holding a boiler of 1,000,000 Btu/hr or more, and a permanent outside air supply sized to the burners, never less than 1 square foot of free louver area. Where the Chief Inspector agrees that a failure is an emergency, a boiler may be installed first with the application filed immediately afterward. A second-hand boiler, or one leaving the state for repair and coming back, needs an approved Application for Permission to Reinstall. Boilers without ASME and National Board stamping need Board approval as a “Tennessee Special” before construction starts.

What does boiler repair in Tennessee cost?

The cost of boiler repair in Tennessee is set by the repair itself, the outage window and the inspection fees, and the state’s fees are fixed by rule. Rule 0800-03-03-.14 sets a $60 boiler inspection fee, $35 for an external inspection, and certificate fees of $50 for a power boiler and $60 for a low-pressure heating boiler or unfired vessel. Special inspections, such as the inspection of a newly permitted boiler, cost more the shorter the notice the owner gives.

Tennessee special inspection fees by working days of notice (Rule 0800-03-03-.14)
Notice givenHalf-day minimumFull-day maximum
1 to 10 working days$350$700
11 to 20 working days$140$280
21 to 30 working days$84$168
More than 30 working days$56$112

The repair price depends on boiler type and size, how many tubes or how much plate is involved, whether postweld heat treatment or volumetric examination is needed, refractory work, access, and whether the plant needs temporary steam while the boiler is down. Paul Industries gives a budget range from comparable scope once it has the nameplate, the inspector’s report and photographs, then a firm price after an inspection of the boiler. Booking the permit inspection more than 30 working days ahead keeps the state’s share of the bill at its lowest.

Who repairs steam and hot water boilers in Tennessee?

Paul Industries repairs steam and hot water boilers in Tennessee: firetube, watertube, cast iron sectional and electric boilers, waste heat units and the unfired steam vessels the state counts as boilers. As a boiler company in Tennessee’s market, Paul Industries handles the whole job under one contract: inspection preparation, NBIC repairs and alterations with the inspector’s acceptance, retubing, refractory, burner and control replacement, safety valve and low-water cutoff work, CSD-1 testing, and complete boiler replacement with the installation permit. Plants that want parts and engineering alone get supply-only service, and owners replacing a plant get a design-build route.

Paul Industries is an East Coast contractor, formerly based in northern New Jersey, then Pennsylvania, and now headquartered in Kilmarnock, Virginia, where boiler repair in Virginia is its home-state service. It takes boiler work across Tennessee, in all 50 states and at plants outside the United States through its international work. The same repair discipline runs through its boiler repair in North Carolina and boiler repair in Georgia pages and across the Southeast.

Boiler repair from Paul Industries for Tennessee plants

Paul Industries keeps Tennessee boilers certificated and running: it opens them for the BI 22-03 and annual internals, makes NBIC repairs and alterations with the inspector consulted and the R forms filed, rebuilds controls to CSD-1, and replaces boilers under a state installation permit. Related Tennessee work includes chiller repair in Tennessee, industrial welding services in Tennessee and tank fabrication in Tennessee, and the state overview sits on the Tennessee page. Send the boiler’s nameplate data, certificate date and inspector’s report to request a quote, or call 201-450-8280.

Standards referenced: Tennessee Code Annotated Title 68, Chapter 122 · Rules of the Tennessee Board of Boiler Rules, Chapter 0800-03-03 · Board Interpretation BI 22-03 · Board Cases BC 22-02, BC 22-03 and BC 12-18 · ASME Boiler and Pressure Vessel Code, Sections I and IV · National Board Inspection Code (NBIC) · ASME CSD-1 · NFPA 85

Frequently asked questions

Who handles boiler repair Nashville hospitals and Middle Tennessee plants rely on?

Paul Industries handles boiler repair in Nashville, Murfreesboro, Franklin, Clarksville and the rest of Middle Tennessee, for hospitals, campuses, office towers and the plants around Spring Hill. Hospital sterilizer steam and heating plants usually run with a standby boiler, so Paul Industries stages the repair one boiler at a time, confirms the standby carries the load, and books the state inspection before the opened boiler goes back together.

Who provides boiler repair Memphis, TN food plants and Shelby County buildings need?

Paul Industries takes boiler work in Memphis, Shelby County and West Tennessee as far as Jackson, for food plants, distribution campuses, hospitals and commercial buildings. Many of these sites run hot water heating boilers that now need a biennial internal under BI 22-03, and Paul Industries schedules that internal in the warm months, when heating demand is low, together with any retubing or section work it reveals.

Who does boiler repair Knoxville, TN, Oak Ridge and Tri-Cities plants call for?

Paul Industries repairs boilers in Knoxville, Oak Ridge, Kingsport, Johnson City and Bristol, from campus heating plants to large process boilers at chemical sites. Privately owned boilers in Oak Ridge follow the state program even where a neighboring federal facility runs its own, so Paul Industries confirms which program covers each unit before planning inspector hold points.

Is boiler repair, Chattanooga included, handled the same way across Tennessee?

Boiler work in Chattanooga follows the same state law and Board of Boiler Rules as the rest of Tennessee: repairs made under the NBIC, the in-service inspector consulted first, and R forms filed afterward. Chattanooga is one of the jurisdictions that reviews its own building permits, so a replacement boiler also needs the city’s permit, which goes with the state installation application.

What are the Tennessee boiler rules and regulations called, and where are they published?

The Tennessee boiler rules and regulations are Chapter 0800-03-03, Rules of the Board of Boiler Rules, published by the Secretary of State, with the latest version dated April 23, 2026. They sit under the boiler statute in T.C.A. Title 68, Chapter 122. The Board also issues numbered interpretations and cases, such as BI 22-03 and BC 12-18, which explain how the rules apply.

What is the Tennessee boiler code for construction?

The Tennessee boiler code for construction is the ASME Boiler and Pressure Vessel Code in its latest edition, adopted by Rule 0800-03-03-.02 along with the latest NBIC for repairs and inspection. Every boiler installed in the state is designed, built, inspected and stamped to the applicable ASME section, carries National Board registration, and arrives with its Manufacturer’s Data Report filed with the Chief Inspector.

How is a Tennessee boiler inspection scheduled after a repair?

The inspector who authorized the repair reviews it and accepts it before the boiler returns to service, and that review often doubles as the internal inspection when the boiler was opened anyway. Paul Industries notifies the inspector at least seven days before the boiler is ready, matching the notice the rules set for a prepared inspection, and keeps the boiler open until the inspector signs off.

Can a Tennessee boiler run after its certificate expires?

Operating a boiler under pressure without a valid inspection certificate is unlawful in Tennessee and a Class C misdemeanor, with each day a separate offense. Certificate inspections can be held up to two months before or after the expiration date, so a repair that threatens the date should be raised with the inspector early. Paul Industries plans repairs to land inside that window.

Does an insurance company inspection count as the Tennessee state boiler inspection?

A Special Inspector employed by the boiler’s insurer makes the certificate inspection for a boiler it covers, and the owner then pays no state inspection fee. The certificate issued on that inspection stops being valid if the insurance lapses, so a change of insurer or a cancelled policy should be handled before the boiler’s certificate date. Uninsured boilers are inspected by state Deputy Inspectors.

What should a plant do first after a boiler accident in Tennessee?

After an incident involving injury or explosion, the owner gives immediate notice to the Chief Inspector’s office and follows with a detailed written report. The boiler and its parts stay in place until the Chief Inspector gives permission, except to save life or limit further damage. Paul Industries begins investigation and repair once the inspector releases the boiler.

What happens when an inspector finds a lap seam crack in an older Tennessee boiler?

A boiler or vessel with a lap seam crack along a riveted longitudinal joint is taken out of use immediately, and patching is prohibited by Rule 0800-03-03-.05. A boiler declared unfit is stamped XXX on either side of its state number. Paul Industries then quotes a replacement boiler, including the installation permit and the removal of the condemned unit.

Can a cast iron sectional boiler be repaired in Tennessee?

Paul Industries replaces a cracked cast iron section rather than welding it, and the boiler is reassembled, pressure tested and inspected before it returns to service. Sectional boilers of cast iron are excluded from the meaning of erect in the Boiler Erectors and Repairers Act, and nonstandard cast iron boilers are limited to 15 psig steam or 30 psig water. Paul Industries supplies the matching sections with the repair.

How long does a Tennessee boiler installation permit last?

An installation permit is valid for twelve months. A boiler still uninstalled after twelve months has its file closed, and the installer applies again with the full package. Any change to the application, such as a different boiler model, needs a revised application with the original permit attached, so Paul Industries confirms the selection before filing.

Who may repair or reset a boiler safety valve in Tennessee?

Safety and safety relief valves are repaired by a holder of a National Board VR Certificate of Authorization, or by an owner-user maintenance organization approved by the Chief Inspector for its own valves. Nobody alters a valve to run above the certificate pressure, and no work is done on a safety appliance while it is under pressure. Paul Industries replaces valves with new ASME stamped units sized to the boiler.

Do electric boilers fall under the Tennessee boiler law?

Electric power and heating boilers are covered like fuel-fired boilers, and those subject to the ASME Code also carry an Underwriters Laboratories label and arrive as a complete unit rather than being converted in the field. Their safety valves are sized at no less than 3.5 pounds of steam per hour per kilowatt, and the power circuit is opened while valves are adjusted.

What records should a Tennessee plant keep after boiler repairs?

A Tennessee plant should keep the posted inspection certificate, the National Board R-1 or R-2 forms with weld procedure and examination records, inspection reports, control test records, and for power boilers the hourly attendant logs required by BC 22-03. Paul Industries hands those over in one package at turnover, indexed to the boiler’s state number so the next inspector finds them quickly.

What should a Tennessee facility send for a boiler repair quote?

Send the nameplate data and state number, the certificate expiration date, the inspector’s latest report or the symptoms, photographs of the problem area, fuel and firing rate, and the outage window the facility can accept. With those, Paul Industries gives a budget range from comparable scope, then a firm price after inspecting the boiler.

Is a Tennessee boiler due for inspection or repair?

Send the boiler’s nameplate and state number, the certificate date and the inspector’s report or symptoms. Call 201-450-8280 or request a quote.