Paul Industries designs, fabricates, installs and maintains ultrapure water systems in Iowa, from pretreatment and reverse osmosis through electrodeionization, polishing, storage and distribution loops, for power stations, industrial boilers, data centers, laboratories and process plants. Iowa feedwater sets the design: river supplies that carry farm nitrate and organic matter, bedrock aquifers under state withdrawal limits, and winter water cold enough to cut membrane output. Paul Industries builds each system around the water the site actually receives.

Request a quote or call 201-450-8280

Headquarters 256 Shore Drive, Kilmarnock, Virginia
Central Iowa feedwater Raccoon and Des Moines rivers; nitrate up to 9.17 mg/L as N in 2025 (DMWW)
Aquifer limit New industrial Jordan withdrawals capped at 2,000 gpm per plant
Boiler inspection Internal every two years for 100,000 lb/h boilers on supervised treatment (Iowa Code 89.3)
Largest power plant Walter Scott Jr. Energy Center, 1,511.7 MW (EIA, 2024)
Reviewed November 2026

Iowa industries that depend on ultrapure water

Iowa industries that depend on ultrapure water include electric generation, plants with high-pressure steam boilers, food and biorefining operations with large boilers, data centers that fill and top up liquid cooling loops, hospitals, universities and laboratories, and manufacturers that rinse, coat or formulate with high-purity water. The quality each one needs differs widely, from boiler makeup measured in fractions of a microsiemens to laboratory type 1 water at the theoretical limit.

The general science of purification stages, specifications and loop materials is on the ultrapure water systems page. This page concentrates on Iowa: the state’s feedwater, its water permits, its boiler inspection law and the users that drive demand here. Iowa’s existing high-purity water systems in Iowa page covers process water inside wet mills; this page goes further down the purity scale.

Designing ultrapure water systems in Iowa around river and aquifer feedwater

Ultrapure water systems in Iowa are designed around two kinds of feedwater: treated municipal water that started as river water, and groundwater from alluvial or bedrock aquifers. Each brings a different set of problems to the pretreatment and reverse osmosis stages, and both change with the seasons.

Central Iowa is a clear example of the first kind. Des Moines Water Works and Central Iowa Water Works serve about 600,000 people from the Raccoon and Des Moines rivers, treating up to 75 million gallons a day at the Fleur Drive plant from the rivers and an infiltration gallery, up to 25 million at the L.D. McMullen plant from collector wells along the Raccoon, and up to 10 million at the Saylorville plant, which already uses ultrafiltration and reverse osmosis to soften and treat. A plant on that supply starts from treated water with residual disinfectant, dissolved organics and seasonal nitrate.

What does Iowa feedwater do to an ultrapure train?

Iowa feedwater loads an ultrapure train with nitrate, organic carbon, disinfectant and cold-season temperature swings. Nitrate is the signature contaminant of Iowa surface water, and it matters to an ultrapure train because it is a monovalent ion that reverse osmosis rejects less completely than hardness or sulfate. The Des Moines Water Works nitrate results for 2025 show treated water reaching as high as 9.17 milligrams per liter as nitrogen, just under the drinking water limit of 10, with agriculture listed as the source. Iowa water quality nitrate levels swing with rainfall and fertilizer timing, so a system sized on a winter sample can be overloaded in a wet spring.

Iowa feedwater conditions and their effect on an ultrapure water train
ConditionIowa exampleEffect on the systemDesign response
NitrateUp to 9.17 mg/L as N in treated Des Moines water, 2025Higher permeate conductivity; more load on EDI and resinTwo-pass RO, EDI sized for peak nitrate, anion capacity margin
Organic carbon2.86 to 3.76 mg/L total organic carbon in treated Des Moines water, 2025Membrane fouling; TOC carried to the loopUltrafiltration or carbon pretreatment, 185 nm UV, TOC monitoring
Disinfectant residualMunicipal supplies leave plants with disinfectantOxidizes polyamide RO membranesCarbon or bisulfite dechlorination with ORP control
Cold winter feedSurface water at its coldest in winterRO output falls with temperatureFeed heating or extra membrane area sized for winter
Groundwater hardness and ironAlluvial and bedrock wellsScaling and fouling on membranesSoftening, antiscalant, iron removal ahead of RO

Organic carbon follows a similar pattern. Treated Des Moines water carried 2.86 to 3.76 milligrams per liter of total organic carbon in 2025, far above what a polishing loop tolerates, so Iowa trains use ultrafiltration or activated carbon ahead of the membranes and ultraviolet oxidation after them. Paul Industries sizes those stages from a full year of the utility’s data, not a single grab sample.

Wells, the Jordan aquifer and Iowa water permits

Wells feed many Iowa industrial sites, and the state’s permit rules apply to them. The Department of Natural Resources requires a water use permit once a site takes more than 25,000 gallons in a day. In the Cambrian-Ordovician aquifer, the Jordan, new industrial withdrawals are limited to 2,000 gallons a minute at a single plant, permits run on a five-year cycle, and once-through cooling is prohibited.

For an ultrapure system the permit sets the ceiling on raw water, so recovery becomes a design priority. Paul Industries designs Iowa trains with high-recovery RO, concentrate recycling where water chemistry allows, and reuse of reject streams for cooling tower makeup or other plant uses, so more of each permitted gallon becomes product water. Groundwater chemistry is checked for hardness, iron, manganese, silica and radionuclides before the pretreatment is chosen.

How is ultrapure water made from Iowa feedwater?

How is ultrapure water made from Iowa feedwater? The train follows the standard sequence, with stages adjusted for nitrate, organics and cold water. Ultrapure water production starts with pretreatment and ends at a recirculating loop that holds quality at every point of use.

An ultrapure water treatment train for Iowa feedwater
StagePurposeIowa note
Multimedia filtration or ultrafiltrationRemove particles, colloids and some organicsUltrafiltration favored where river-derived organics run high
Softening or antiscalantPrevent scale on membranesEssential on hard well water
Carbon or bisulfite dechlorinationProtect membranes from oxidizersRequired on municipal feed with disinfectant residual
Two-pass reverse osmosisRemove most dissolved ions and organicsSecond pass handles nitrate passage; winter flux sets membrane count
Membrane degasificationRemove carbon dioxide and oxygenProtects EDI and lowers resistivity drift
ElectrodeionizationContinuous ion removal without chemical regenerationSized for peak spring nitrate
185 nm UV, polishing mixed bed, final filterDestroy TOC, remove trace ions and particlesHolds loop quality through feedwater swings
Storage and recirculating loopDeliver water at specification to every point of useNitrogen-blanketed tank, continuous flow, sanitizable materials

Each stage is ultrapure water equipment in its own right, and the ultrapure water filter at the end of the loop is the last line of defense against particles. Paul Industries fabricates the skids, piping and loop as a system, tests each stage, and delivers documentation that ties the design to the feedwater data it was built on.

Matching water quality to each Iowa user

Matching water quality to each Iowa user keeps a system from being overbuilt for one use or short for another. A plant with both a boiler and a quality control lab, or a campus with both liquid-cooled halls and a research building, often needs two grades from one central system, with a polisher only where the top grade is used.

Typical purity targets and system types for Iowa ultrapure and high-purity users
UserQuality targetTypical system
High-pressure boiler makeupVery low conductivity, silica and sodium, set by the boiler maker and steam cycleRO, degasification, EDI or mixed bed, continuous analyzers
Nuclear makeup and reactor waterPlant-specific limits among the tightest in industryMulti-stage demineralizers, RO and polishing
Data center liquid cooling fillLow conductivity and chloride per the coolant and IT vendorRO with EDI or DI polishing, fill and makeup skid
Laboratory type 1Resistivity near 18.2 megohm-cm, low TOC and bacteriaCentral RO and EDI with point-of-use polishers or a polished loop
Pharmaceutical and animal health productionUSP Purified Water or Water for Injection per the monographsSanitary RO and EDI loops, distillation for WFI
Electronics and precision rinsingUser specification for particles, silica, metals and TOCFull UPW train with polishing loop

Pharmaceutical and animal health production deserves a note. Water for those products follows the USP monographs and the manufacturer’s quality system, with sanitary design, validated sanitization and documented sampling, which makes it its own discipline apart from industrial UPW even when the treatment stages look similar. Paul Industries builds both, and the sanitary side connects to CIP and SIP systems in Iowa and the plant’s process piping.

Operating an ultrapure system through an Iowa year

Operating an ultrapure system through an Iowa year means following the feedwater as it changes. Spring rain and fertilizer runoff raise nitrate and organics in river-derived supplies; summer brings warm water, faster biological growth and higher RO output; and winter brings cold feed and reduced membrane output. A system tuned once at startup drifts out of balance within a season.

Paul Industries sets Iowa systems up with trend logging on feed conductivity, permeate conductivity, normalized RO flow and pressure, EDI current and product resistivity, so operators see change before it reaches the loop. Membrane cleaning is scheduled from normalized data rather than the calendar, cartridge and UV lamp changes follow run hours, and loop sanitization follows the user’s bacterial limits. Service visits review the trends with the operators and adjust recovery, antiscalant dose and EDI settings for the season ahead.

Spare parts planning matters as much as tuning. Membranes, EDI modules, UV lamps, cartridges and analyzer sensors have long enough lead times that a site running a single train keeps critical spares on the shelf, and sites that cannot tolerate any outage run duplex trains or keep a portable exchange service on contract. Paul Industries sets the spares list with the owner during startup and keeps it current as components age.

Boiler makeup and Iowa’s boiler inspection law

Boiler makeup is a major use of high-purity water at many Iowa plants, and Iowa’s boiler law gives well-treated boilers a scheduling advantage. Iowa Code chapter 89, enforced by the Department of Inspections, Appeals, and Licensing, normally requires internal and external inspection at least every twelve months for boilers above 15 pounds per square inch. Boilers of 100,000 pounds per hour or more that hold only water under continuous internal treatment, supervised by a graduate engineer or chemist or someone with equivalent experience, are instead inspected internally at least every two years, with the owner keeping water analyses taken at intervals of no more than 48 hours of operation.

Longer intervals are available in some cases. An owner in the state’s occupational safety and health voluntary protection program at star status, or an unfired steam vessel covered by the federal process safety management standard, moves to yearly external and four-yearly internal inspections, and the director may grant up to seven years for objects covered by process safety management with longer planned outage cycles. Every one of those intervals rests on water treatment records. A demineralized makeup system with reliable conductivity, silica and sodium monitoring produces the data the law asks for, and keeps the boiler clean enough to pass the internal inspection when it comes.

Iowa power stations and demineralized water

Iowa power stations use demineralized water in large volumes. Energy Information Administration data list the Walter Scott Jr. Energy Center, a MidAmerican Energy coal plant, as Iowa’s largest plant at 1,511.7 megawatts in 2024, followed by the Louisa, Ottumwa and George Neal coal units and gas plants at Marshalltown, Emery and Greater Des Moines. Steam cycles at those pressures need makeup water with very low conductivity and silica, produced by RO, electrodeionization or mixed bed systems.

Nuclear generation may return too. Google and NextEra Energy announced in October 2025 a collaboration under which the Duane Arnold Energy Center, Iowa’s only nuclear plant, is expected back online in early 2029 with more than 600 megawatts. A nuclear plant’s makeup and reactor water systems hold some of the tightest purity specifications in industry. Paul Industries designs, builds and services demineralizer, RO and polishing systems for power generation, and the boiler water treatment page covers the chemistry inside the steam cycle.

Data centers, liquid cooling and treated fill water

Data centers are a growing source of demand for treated water in Iowa. Liquid cooling loops are filled and topped up with deionized or RO water and an approved coolant, because nitrate, chloride and hardness from tap water upset inhibitors and foul fine cold plate channels. Campuses with many halls add a permanent fill water system instead of trucking in drums. Paul Industries builds those systems and the loops they serve, described under data center liquid cooling in Iowa and data center cooling in Iowa.

Laboratories, hospitals and type 1 ultrapure water

Laboratories at Iowa universities, hospitals, research centers and quality control labs at manufacturing plants need water at the top of the purity scale. Ultrapure water for laboratory use, including ultrapure water for HPLC, molecular work and instrument rinsing, is produced by central systems feeding a building loop or by point-of-use polishers fed from a central RO and EDI system.

Type 1 ultrapure water and the ultrapure water specification

Type 1 ultrapure water, the reagent-grade classification in ASTM D1193, approaches the theoretical resistivity of pure water, 18.2 megohm-centimeters at 25 degrees Celsius, with very low organic carbon, particles and bacteria. The ultrapure water specification for a given lab sets those limits and how they are measured. Paul Industries designs central systems and loops that deliver the specified quality at each outlet, with continuous monitoring at the loop return.

Ultrapure water conductivity, resistivity and pH

Ultrapure water (UPW) quality is tracked through conductivity, resistivity and TOC. Ultrapure water conductivity and ultrapure water resistivity are two views of the same measurement, and they are read inline with temperature compensation, because a sample exposed to air absorbs carbon dioxide within seconds and loses resistivity. The same effect makes ultrapure water pH almost impossible to measure meaningfully with a standard probe: there are so few ions that the reading drifts. Labs monitor resistivity and TOC instead, and Paul Industries installs the analyzers that do it.

Electronics and coatings: ultrapure water for semiconductor manufacturing standards

Iowa’s electronics, coatings and precision manufacturing plants use water for rinsing parts, mixing solutions and cleaning surfaces, and the most demanding of them borrow from the standards developed for ultrapure water for semiconductor manufacturing, with limits on particles, silica, dissolved oxygen, metals and TOC far tighter than boiler makeup. Paul Industries builds systems to the user’s specification and selects loop materials, such as PVDF or high-purity polypropylene, that do not leach into the water.

Loop materials, storage and sanitization

Loop materials, storage and sanitization decide whether the water that leaves the purification skid still meets specification at the far end of the building. Ultrapure loops are run in PVDF, high-purity polypropylene or, for hot water sanitized systems and pharmaceutical service, electropolished stainless steel, with welded or fused joints and no dead legs at the points of use. Storage tanks are sized small and blanketed with nitrogen so the water absorbs less carbon dioxide and oxygen, and the loop runs continuously at a velocity that discourages biofilm.

Sanitization methods follow the material: hot water or ozone for systems built to tolerate them, chemical sanitization for plastic loops, and UV in the loop for continuous control. Paul Industries fabricates and installs the loop, passivates stainless sections where they are used, and documents weld logs, cleaning and sanitization for the turnover file. Sites with sanitary product contact also receive passivation of the stainless surfaces after fabrication, with the chemistry, contact time and verification recorded for the quality file.

Permits, discharges and air rules

Permits for an Iowa ultrapure system are usually simple on the air side and more involved on the water side. Iowa’s air construction permit rules list process water filtration systems, demineralizers, demineralized water tanks and demineralizer vents among exempt equipment, along with boiler water treatment operations other than cooling towers and lime silos and deaeration of water. Raw water above 25,000 gallons a day needs a DNR water use permit, and RO concentrate, regeneration waste and EDI reject go to the plant’s wastewater system under its discharge permit or the city’s sewer use rules.

Paul Industries designs Iowa systems to keep waste low and predictable: high recovery, EDI in place of chemically regenerated beds where possible, and reuse of reject water. Where regeneration chemicals are used, neutralization and metering are included so the discharge stays within its limits.

What does an ultrapure water system cost in Iowa?

Ultrapure water system cost in Iowa depends on flow, the purity required, feedwater chemistry, the amount of redundancy, the loop length and materials, monitoring and the documentation the user needs. A small laboratory ultrapure water machine fed from a building RO system is a modest purchase; a power plant demineralizer or a site-wide loop for a manufacturing plant is a capital project. The ultrapure water price per gallon after installation is driven by power, membranes, resin, cartridges and labor.

Power is a smaller share in Iowa than in many states. With Iowa industrial power averaging 6.80 cents a kilowatt-hour in 2024, a 30 kilowatt RO and loop pump load running all year costs about $17,870 in electricity. Paul Industries prices Iowa systems from the feedwater analysis, the product water specification and the flow profile, with equipment, installation, testing and documentation shown separately. Owners choose a supply-only ultrapure water system skid, design-build delivery or complete installation.

Who installs ultrapure water systems in Iowa?

Paul Industries installs ultrapure water systems in Iowa, along with the pretreatment, storage and loops that serve them. Its home office is 256 Shore Drive, Kilmarnock, Virginia; it was formerly based in northern New Jersey and then Pennsylvania, and today it accepts water system projects anywhere in Iowa, the other 49 states and overseas. Among ultrapure water companies working in the state, Paul Industries designs, fabricates, installs, starts up, validates and maintains the complete system under one contract.

The same work at the company’s home base is described on ultrapure water systems in Virginia, and the Great Lakes version on ultrapure water systems in Michigan. For pharmaceutical-grade loops and sanitary piping in Iowa, see sanitary process piping in Iowa, and for boiler plants, boiler repair in Iowa.

Ultrapure water from Paul Industries across Iowa

Paul Industries builds and services ultrapure water systems for Iowa power stations, industrial boilers, data centers, hospitals, universities, laboratories and manufacturers from Sioux City and Council Bluffs across Ames and the Des Moines metro to Waterloo, Cedar Rapids, Iowa City, Dubuque and Davenport. The scope covers pretreatment, RO, EDI, polishing, storage, loops, monitoring and service, and the high-purity water systems that sit upstream of them. The Iowa and Midwest pages show the other plant systems Paul Industries builds in the region. Send a feedwater analysis, the product water specification and the flow profile, and request a quote.

Standards referenced: ASTM D1193 (reagent water) · ASME Boiler and Pressure Vessel Code · Iowa Code chapter 89 (boilers and unfired steam pressure vessels) · 567 IAC 50 (water use permits) · 567 IAC 22 (air construction permit exemptions) · ASME BPE · USP Purified Water

Frequently asked questions

Which firm puts in UPW systems on Des Moines metro water?

Paul Industries designs, builds and services ultrapure water systems for plants, labs and data centers in Des Moines, Ankeny, Ames and the rest of central Iowa. Systems on central Iowa municipal water are designed for river-derived nitrate and organics, with two-pass RO, EDI and UV sized for the spring peak reported by the water utility.

Does Paul Industries install ultrapure water systems in Cedar Rapids, Iowa City and the Quad Cities?

Yes. Paul Industries installs and maintains ultrapure water systems in Cedar Rapids, Iowa City, Davenport, Bettendorf and across eastern Iowa, for power generation, manufacturing, hospitals, universities and data centers. Each system is designed from the site’s own feedwater analysis, whether it comes from a city supply or plant wells.

Which ultrapure water purification system suits an Iowa power plant?

Most new systems use pretreatment, two-pass RO and electrodeionization, followed by a polishing mixed bed for minimum conductivity and silica, with membrane degasification ahead of the EDI. Existing regenerated demineralizer trains are upgraded stage by stage where that suits the plant. Paul Industries sizes the system from the feedwater and the steam cycle’s makeup specification.

How does Iowa's boiler law reward good boiler water treatment?

Iowa Code 89.3 lets boilers of 100,000 pounds per hour or more, holding only water under continuous treatment supervised by a graduate engineer or chemist, move from yearly to two-yearly internal inspection, provided the owner keeps water analyses taken at least every 48 hours of operation. Reliable demineralized makeup and monitoring produce exactly those records.

What does Des Moines Water Works nitrate mean for an RO system?

Nitrate passes RO membranes more readily than hardness or sulfate, so higher nitrate means higher permeate conductivity and more load on EDI and polishing resin. Des Moines Water Works reported treated water up to 9.17 milligrams per liter as nitrogen in 2025. Paul Industries designs central Iowa systems with a second RO pass and EDI capacity for those peaks.

Can you drink ultrapure water from an industrial system?

Industrial ultrapure water is produced for process use, not drinking. It contains almost no minerals, it is aggressive to materials because it seeks to dissolve ions, and the loops carrying it are designed and monitored for process purity rather than as potable water systems. Paul Industries keeps ultrapure loops separate from drinking water piping.

What is the difference between DI water vs ultrapure water?

Deionized water has had dissolved ions removed by ion exchange, and its quality can range widely. Ultrapure water goes further: ions, organics, particles, bacteria and dissolved gases are all removed to tight limits, and quality is held by a recirculating loop with continuous monitoring. Ultrapure water is deionized, but most DI water is not ultrapure.

How does ultrapure water vs distilled water compare for an Iowa lab?

Distillation removes most ions and many organics but leaves water that picks up contaminants in storage and rarely reaches top laboratory grades. Ultrapure water vs distilled water favors the ultrapure system for HPLC, molecular work and trace analysis, because it delivers type 1 quality continuously at the point of use. Paul Industries builds central and point-of-use systems for Iowa labs.

Do Iowa ultrapure water systems need an air permit?

Iowa’s air construction permit rules list demineralizers, demineralized water tanks, demineralizer vents and process water filtration systems among exempt equipment, so the purification system itself usually needs no air permit. Water use permits apply to raw water above 25,000 gallons a day, and discharges follow the plant’s wastewater permit or city rules.

How much water can an Iowa plant draw from the Jordan aquifer for ultrapure water?

New industrial withdrawals from the Jordan aquifer are limited to 2,000 gallons a minute at a single plant, with permits on a five-year cycle, and any withdrawal above 25,000 gallons a day needs a DNR permit. Paul Industries designs high-recovery systems so more of the permitted water becomes product.

Why does an Iowa RO system make less water in winter?

Membrane permeability falls as water gets colder, so the same RO system produces less permeate at the same pressure when feed temperatures drop in winter. Iowa systems are sized for winter feed, or a feed heater recovers output. Paul Industries checks winter production during startup and sets pressure and recovery limits for cold months.

What does nuclear plant restart planning mean for ultrapure water in Iowa?

The Duane Arnold Energy Center is expected back online in early 2029 under the NextEra Energy and Google collaboration announced in October 2025. Nuclear plants hold some of the tightest makeup and reactor water specifications in industry, with demineralizers, RO and polishing in continuous service. Paul Industries designs and builds that class of water system.

What is the ultrapure water cost per year to run in Iowa?

Operating cost comes from power, membranes, EDI stacks, resin, cartridges, chemicals, analyzers and labor. Power is relatively cheap in Iowa, so a continuous 30 kilowatt pump load comes to roughly $17,870 a year. Paul Industries estimates the full annual cost during design.

How much does ultra pure water cost to produce compared with buying it?

For small laboratory volumes, bottled or delivered water can make sense, but anywhere water is used daily in volume an on-site system costs far less per gallon and delivers consistent quality. The break-even depends on daily volume and purity. Paul Industries compares on-site production with delivered water for each Iowa user.

Which ultrapure water companies maintain systems after startup in Iowa?

Paul Industries maintains Iowa ultrapure systems from any manufacturer, with scheduled membrane cleaning, EDI and resin service, cartridge and UV lamp changes, analyzer calibration, sanitization and trend review. Reports after each visit show feedwater, permeate and loop quality over time.

Can an Iowa ultrapure loop be extended while the plant keeps running?

Yes, with planning. New branches are prefabricated, cleaned and tested off site, tied in during a short planned outage or through valved connections installed earlier, then flushed and sanitized before they join the loop. Paul Industries plans each extension so loop quality is restored quickly and verified before users draw water.

Which feedwater data does an Iowa UPW quote start from?

Send a recent feedwater analysis, or the water utility’s annual report and the plant’s well data, the product water specification, peak and average flow, points of use, available space and utilities, and any documentation requirements. Paul Industries prices pretreatment, purification, loop, monitoring and installation separately.

Planning an ultrapure water system in Iowa?

Send a feedwater analysis, the product water specification and the flow profile. Call 201-450-8280 or request a quote.