Paul Industries provides boiler repair in Maryland for manufacturing plants, hospitals, universities and commercial buildings, making code repairs to the National Board Inspection Code, retubing firetube boilers, rebuilding burners and controls, and returning each unit to service with the paperwork the state requires. Because Maryland law and COMAR 09.12.01 reach nearly every boiler outside a private home, each pressure-boundary repair runs alongside inspectors, report deadlines and certificate cycles. Headquartered at 256 Shore Drive in Kilmarnock, Virginia, Paul Industries is an East Coast contractor that accepts boiler work across the state, from Baltimore and the I-270 corridor to Hagerstown and the Eastern Shore.

Request a quote or call 201-450-8280

Headquarters 256 Shore Drive, Kilmarnock, Virginia
State law Public Safety Article 12-901 and following; COMAR 09.12.01
Power boilers Certificate inspection every year, external under pressure
Heating boilers Certificate inspection every two years (COMAR 09.12.01.14)
Repair reports To the Chief Boiler Inspector and owner within 30 days
Accidents Reported to the Chief Boiler Inspector within 24 hours
Reviewed November 2026

Boiler repair in Maryland under the Boiler and Pressure Vessel Safety Act

Boiler repair in Maryland is governed by the Maryland Boiler and Pressure Vessel Safety Act, codified at sections 12-901 and following of the Public Safety Article, and by the Board of Boiler Rules regulations in COMAR 09.12.01, which the Division of Labor and Industry administers through the Chief Boiler Inspector. Together they set which boilers are covered, how often they are inspected, who may inspect them, and how a repair is made and reported. Anyone looking for the Maryland boiler code in one place will find it split between those two sources, with the National Board Inspection Code (NBIC) adopted for repairs and the ASME Boiler and Pressure Vessel Code for construction.

The Act covers boilers and pressure vessels broadly and then lists exemptions. Heating boilers in private homes and in apartment houses with fewer than six family units sit outside the inspection sections, as do farm boilers used only for agriculture. Small hot water supply boilers are exempt when they carry a relief valve, are fired directly by oil, gas or electricity, and stay within 200,000 Btu per hour of heat input, 210 degrees Fahrenheit and 120 gallons of nominal water capacity. Everything larger in a plant, hospital, school, office tower or apartment complex is covered, which is why commercial boiler repair Maryland building owners commission is almost always code work as well as mechanical work.

The national view of boiler faults and repair methods is on the boiler repair page. This page stays with what the Maryland rules add to a repair, the regions where boilers work hardest, and the decisions Maryland owners face as building emissions standards arrive.

Maryland boiler inspection requirements: annual, biennial and extended cycles

Maryland boiler inspection requirements depend on the type of boiler: power boilers and high pressure, high temperature water boilers receive a certificate inspection every year and an external inspection under pressure where possible, while heating boilers, hot water boilers outside that class and pressure vessels receive a certificate inspection every two years. A certificate inspection is internal wherever the construction allows it, and otherwise as complete as the design permits.

The state also lets a well-run steam plant stretch its cycle. The Board may extend the interval for a power boiler to two years where the boiler has internal continuous water treatment under the general supervision of a professional engineer experienced in boiler water, and the owner keeps records of when and why the boiler was out of service along with chemical and physical analyses of boiler water samples taken at intervals of no more than 48 hours of operation. A site that wants that extension needs a treatment program that produces those records every week of the year, which is where boiler water treatment and the repair program meet.

Maryland certificate inspection cycles by equipment class
EquipmentCertificate inspectionNotes for repair planning
Power boilers (steam above 15 psi)Every year, plus an external inspection under pressure where possibleInternal inspection drives most repair scopes; plan the outage around it
High pressure, high temperature water boilersEvery yearSame annual cycle as power boilers
Power boilers with engineer-supervised continuous water treatmentUp to every two years, if the Board grants the extensionOut-of-service log and water analyses at no more than 48-hour intervals must be on file
Low pressure steam and hot water heating boilersEvery two years (COMAR 09.12.01.14)Hot water units usually get an external inspection unless the inspector calls for internal
Small hot water supply boilersExempt up to 200,000 Btu/h, 210 F and 120 gallonsLarger domestic water heaters in commercial buildings fall back under the Act
Heating boilers in homes and apartment houses under six unitsExempt from the inspection sectionsApartment buildings with six or more units are covered

Who carries out a Maryland boiler inspection?

A Maryland boiler inspection is carried out by a special inspector employed by the boiler’s insurer, or by an authorized inspection agency working for that insurer, whenever the boiler is covered by an insurance policy; an owner without such coverage contracts with the Chief Boiler Inspector, a deputy boiler inspector, a special inspector or an authorized inspection agency. The Chief Boiler Inspector and the deputies also investigate accidents and complaints and monitor the work of special inspectors.

The inspector gives the owner at least seven days of notice before an internal inspection. The owner then has the unit drained, washed and cooled, manhole and handhole plates and washout plugs removed, grates and the test gauge taken out where needed, and the unit isolated from any common steam or water header so no one is exposed to backflow. When a hydrostatic test is called for, the regulations cap the test at one and a half times the maximum allowable working pressure and recommend test water between 70 and 140 degrees Fahrenheit. Paul Industries prepares units for internal inspection, opens and closes them, runs hydrostatic tests through hydrostatic testing procedures, and turns the inspector’s findings into a priced repair scope while the boiler is still open.

From inspection finding to signed repair report

A Maryland boiler repair runs to the National Board Inspection Code, which COMAR 09.12.01.27 adopts for every repair and alteration of a boiler or pressure vessel, and it ends with a special inspector, a deputy boiler inspector or the Chief Boiler Inspector confirming that the finished work conforms. Within 30 days of completion, a written report of the repair goes to both the Chief Boiler Inspector and the owner, listing the owner and location, the registration numbers, the manufacturer and serial number, and a description of the work.

How a code repair moves through a Maryland boiler room
StepWhat happensRecord produced
1. FindingInspector or operator finds a defect: tube leak, wasted stays, cracked ligament, bulged furnace, failed safety deviceInspection report or operator log entry
2. ScopePaul Industries opens, cleans and measures the damaged area and writes the repair method against the NBICWritten repair plan, material list, thickness readings
3. Inspector reviewPlan reviewed with the inspector before welding starts on the pressure boundaryInspector acceptance of the method
4. RepairRetube, plug or replace tubes, weld repair, stay or patch work, refractory, controlsWeld procedure and welder records, material certificates
5. TestHydrostatic test as the inspector directs, capped at 1.5 times MAWPTest record with pressure and hold time
6. CompletionInspector confirms the repair conforms to the NBICSigned repair form
7. ReportRepair report sent to the Chief Boiler Inspector and the ownerReport filed within 30 days of completion

Welded repairs on the pressure boundary

Welded repairs on tubes, tubesheets, shells, furnaces and headers are made under the National Board R program with the inspector consulted before the work and present for acceptance after it. The repair method, weld procedure, filler metal and heat treatment come from the NBIC and the original construction code, ASME Section I for power boilers or Section IV for heating boilers. Retubing a firetube boiler, replacing waterwall tubes in a watertube unit and seal-welding rolled tube ends are the repairs Paul Industries performs most often under that program, along with the industrial welding services in Maryland that surround a boiler room.

Safety valves, low-water cutoffs and fittings

COMAR 09.12.01.26 requires repairs and replacements of fittings and appliances to meet the requirements for new installations, so a replacement safety valve, low-water fuel cutoff, gauge glass or feedwater valve is chosen against the current rule, not simply matched to the old part. Safety valves are sized to the boiler’s relieving capacity and set at or below its maximum allowable working pressure, and a valve that has been repaired carries the nameplate of the organization that reset and sealed it. Paul Industries replaces and tests these devices during the job and lists each one, with its set pressure and capacity, in the closeout record.

What must happen within 24 hours of a boiler accident in Maryland?

Within 24 hours of a boiler accident or explosion in Maryland, the owner or operator must notify the Chief Boiler Inspector by email and by telephone, and the boiler and its surroundings must be left undisturbed until an inspector has examined them, except where moving something is needed to save a life. The notice describes the location, the date and time, the boiler’s registration and manufacturer details, its type and maximum allowable working pressure, and any injuries or damage.

The Chief Boiler Inspector or a deputy then investigates. After the inspector releases the equipment, Paul Industries makes the boiler room safe, isolates the damaged unit, opens it for a full assessment and prices the repair or replacement, keeping any remaining units on line. Low-water incidents, the usual cause of overheated tubes and bulged furnaces, also lead to a review of the cutoffs, feedwater controls and the deaerator upstream.

The Maryland stationary engineer license and who runs the boiler during a repair

The Maryland stationary engineer license is required of anyone operating a steam plant that generates more than 15 psi at 30 horsepower or more, or a hot water boiler above 160 psig or 250 degrees Fahrenheit, and the state issues it in five grades by plant horsepower. The license belongs to the plant’s operators, and the law forbids a plant from letting an unlicensed individual provide services as a stationary engineer. Searches for a Maryland boiler operator license land on the same program.

Maryland stationary engineer grades by plant size
GradePlant coveredTypical Maryland setting
Grade 530 to 99 horsepower, building not open for public useSmall process plants and warehouses
Grade 430 to 99 horsepower, any buildingSchools, office buildings, apartment complexes
Grade 3100 to 299 horsepowerMid-size plants, county buildings, smaller hospitals
Grade 2300 to 499 horsepowerLarge hospitals, campus heating plants
Grade 1500 horsepower and moreUniversity central plants, large manufacturing steam systems

The license shapes the repair calendar. The plant’s license holder isolates and locks out the unit, hands it over for the outage, and takes it back for firing after the inspector accepts the work. Paul Industries agrees those handover points with the chief engineer before the job starts, then starts the burner, checks the flame safeguard and combustion, and proves every safety device with the plant’s engineer present.

Burner repairs and MDE air permits

Burner repairs in Maryland can touch air quality permits issued by the Maryland Department of the Environment (MDE) under COMAR 26.11, because a new burner, a fuel change or a larger firing rate is a modification of fuel-burning equipment. Equipment burning gas or No. 1 or No. 2 fuel oil with a heat input under 1,000,000 Btu per hour is exempt from a permit to construct under COMAR 26.11.02.10, and MDE offers a general permit to construct for boilers from 1 to under 10 million Btu per hour; larger units and other fuels go through an individual permit.

Like-for-like repairs of burner parts, linkages, flame scanners and controls leave the permitted design unchanged. Paul Industries checks the boiler’s permit before quoting a burner replacement or conversion, sets combustion to the permitted limits after the repair, and records the flue gas readings with the job.

Repair or replace: BEPS and the Maryland boiler decision

Maryland’s Building Energy Performance Standards (BEPS), adopted under the Climate Solutions Now Act of 2022, now sit behind most repair or replace decisions in larger buildings, because they cover commercial, multifamily and state-owned buildings of 35,000 square feet and more and score them on direct greenhouse gas emissions, which come mainly from boilers and other on-site combustion. Benchmarking began in 2025, interim direct emissions standards begin in 2030, and the final standard is net zero direct emissions in 2040, with an alternative compliance fee for buildings that miss a standard; the General Assembly amended the fee provisions in 2025. Manufacturing buildings are exempt, and Montgomery County runs its own program in place of the state one.

For a hospital, campus or office building, that turns a failure into a planning question. A sound unit with a repairable fault still earns its repair, often for many years, while one near the end of its life in a covered building is worth comparing against a replacement plan that fits the 2030 and 2040 standards. Plants exempt from BEPS make the decision on condition, efficiency and outage risk alone.

Signals that point to repair or to replacement for a Maryland boiler
FactorPoints toward repairPoints toward replacement
Pressure partsDefect confined to tubes, a few stays or a patch areaWidespread wastage, repeated furnace or tubesheet cracking
Inspection historyOne finding, repaired and acceptedFindings at every certificate inspection
BEPS exposureExempt building, or a plan already set for 2030Covered building with no path to the 2030 interim standard
EfficiencyCombustion and stack temperature close to the original ratingHigh stack losses that tuning will not recover
Air permitRepair keeps the permitted burner and fuelBurner or fuel change needed anyway
LoadBoiler size still matches the steam or hot water demandLoad has shrunk, leaving the boiler short-cycling

When replacement wins, the new unit starts a fresh paperwork cycle. The person installing it gives the state at least 30 days of notice before installation, the maker’s data report goes to the state through the National Board, and the first certificate inspection of equipment new to Maryland carries no state fee.

Boiler repair across Maryland’s regions

Boiler repair across Maryland follows the building stock: older steam plants and hospitals in Baltimore, laboratory and biomanufacturing heat loads on the I-270 corridor and in Frederick, state and naval buildings around Annapolis, and food processing plants on the Eastern Shore.

Steam plants and boiler repair, Baltimore City and Baltimore County

Baltimore has a large stock of older firetube and watertube boilers in hospitals, universities, apartment towers and plants along the harbor, many of them steam units that have been retubed more than once. Steam boiler repair, Baltimore style, often means work in a tight basement boiler room with limited rigging access, so tubes, burners and refractory are staged and the outage is planned around the building’s other boilers. Paul Industries also repairs the condensate return, steam traps and feedwater equipment whose failures show up as tube and furnace damage.

The I-270 corridor, Frederick and Columbia

Biotech and vaccine plants in Rockville, Gaithersburg, Germantown and Frederick run boilers for heating, humidification and the feed to clean steam generators, and those units sit inside validated facilities where outages are scheduled months ahead. Repairs there are planned into shutdowns, with change records for the plant’s quality system, and the same plants often run their chilled water on machines covered by chiller repair in Maryland.

Annapolis, Southern Maryland and the Eastern Shore

State buildings in Annapolis, campuses and county facilities in Southern Maryland, and poultry and vegetable processing plants around Salisbury and the Eastern Shore rely on hot water and process steam. Units near the water face damp mechanical rooms and corrosion at casings and stacks, and food plants need steam for sanitation as much as for process, so repairs are timed between production runs.

Hagerstown and Western Maryland

Colder winters in Hagerstown, Cumberland and the western counties mean longer heating seasons and harder starts, and repairs there are usually done in late spring or summer so the plant enters winter with every unit available.

Public work: prevailing wage on Maryland boiler contracts

Maryland’s prevailing wage law applies to public work of $250,000 or more where a state unit is the contracting body and any state money is involved, or where a county or other political subdivision contracts and the state funds 25 percent or more of the project, including school construction. Since October 1, 2022, the law also reaches services under mechanical systems service contracts for heating, ventilation and air-conditioning systems that form part of a public work contract. Paul Industries prices this work for schools, counties and state agencies with the applicable wage determination and keeps the payroll records the contract calls for.

How much does boiler repair in Maryland cost?

The cost of boiler repair in Maryland depends on the fault, the unit’s type and size, access and rigging in the mechanical room, whether the work is a welded code repair with inspector involvement, the outage window and any temporary steam or hot water the building needs while the unit is down. A control or burner repair costs a fraction of a retube, and a retube costs a fraction of a replacement, which adds removal, rigging, setting, piping, electrical and permits.

State inspection fees are a small, published part of the total when the state does the inspecting: under Public Safety Article 12-909, the initial certificate inspection of a boiler not previously inspected in Maryland carries no charge, a follow-up inspection to confirm compliance is $50, and inspections at a fabrication or repair facility or an NBIC repair review are charged at $250 for a half day. Boilers covered by an insurance policy are inspected by the insurer’s special inspector instead. Paul Industries prices each repair after opening and measuring the pressure parts, with parts, labor and testing shown separately, and adds a replacement budget beside any major repair so the owner can compare the two.

Who performs boiler repair in Maryland?

Paul Industries performs boiler repair in Maryland for plants, hospitals, universities, government buildings and commercial properties, covering firetube, watertube, cast iron sectional and electric boilers, burners and controls, and the steam and hot water systems around them. Paul Industries is an East Coast contractor headquartered in Kilmarnock, Virginia, formerly based in northern New Jersey and then Pennsylvania, and repairs boilers in every Maryland county, across all 50 states and at plants outside the United States.

Because one contract can cover the heating plant, its piping and the vessels around it, a single diagnosis follows the fault wherever it sits. Steam and condensate lines are covered on process piping in Maryland, and replacement receivers, blowdown tanks and other code vessels on pressure vessel fabrication in Maryland. Owners with plants in the headquarters state can see the same work on boiler repair in Virginia, and Pennsylvania sites on boiler repair in Pennsylvania.

Paul Industries on Maryland boilers: repairs, retubes, burners and replacements

Paul Industries repairs, retubes, rebuilds, maintains, supplies and installs boilers across Maryland, offering supply-only replacement units, design-build boiler plant upgrades and complete installation through startup and the first certificate inspection. Scheduled service is available under service contracts that line up with each boiler’s certificate cycle. For a repair, send the boiler make, type and size, its Maryland and National Board numbers, the latest inspection report and a description of the fault; for a replacement study, add the steam or hot water load and the building’s BEPS status. Call 201-450-8280 or request a quote. Every other service Paul Industries offers Maryland owners is gathered on the Maryland hub.

Standards referenced: Maryland Boiler and Pressure Vessel Safety Act (Public Safety Article, Title 12, Subtitle 9) · COMAR 09.12.01 (Board of Boiler Rules) · National Board Inspection Code (NBIC) · ASME Boiler and Pressure Vessel Code, Sections I and IV · Maryland Stationary Engineers licensing · COMAR 26.11.02 (MDE air quality permits) · Maryland Building Energy Performance Standards (Climate Solutions Now Act of 2022) · Maryland prevailing wage law (State Finance and Procurement Article, Title 17, Subtitle 2)

Frequently asked questions

Who repairs boilers along the I-270 corridor in Rockville, Gaithersburg and Germantown?

Paul Industries repairs boilers along the I-270 corridor, including biotech, vaccine and laboratory buildings in Rockville, Gaithersburg, Germantown and Montgomery County. Boilers in those plants often feed humidifiers and clean steam generators inside validated areas, so repairs are planned into scheduled shutdowns with change records for the quality system. Montgomery County buildings also fall under the county’s own building energy performance program. Call 201-450-8280 or request a quote with the boiler details and the shutdown window.

Does Paul Industries handle boiler work in Annapolis, Southern Maryland and on the Eastern Shore?

Paul Industries takes boiler work in Annapolis, across Southern Maryland and on the Eastern Shore, including Salisbury, Easton and the poultry and food processing plants of the Delmarva Peninsula. Food plants there use steam for sanitation and process heat, so repairs are scheduled between production runs, and boilers near the water get extra attention at casings, stacks and electrical enclosures where damp air causes corrosion.

Who repairs boilers in Frederick, Hagerstown and Western Maryland?

Paul Industries repairs boilers in Frederick, Hagerstown, Cumberland and the western counties, at biomanufacturing plants, hospitals, schools and industrial sites. Longer, colder heating seasons in Western Maryland make the spring and summer months the usual repair window, so each plant goes into winter with every boiler accepted by the inspector and its certificate current. Send the boiler data and inspection report to get the work scheduled.

What makes a boiler repair Maryland inspectors will accept?

An acceptable repair follows the National Board Inspection Code, which COMAR 09.12.01.27 adopts, uses a method agreed with the inspector before welding on the pressure boundary, and is tested as the inspector directs. A special inspector, a deputy boiler inspector or the Chief Boiler Inspector then confirms the work conforms, and a written report reaches the Chief Boiler Inspector and the owner within 30 days of completion.

Can a power boiler in Maryland go two years between certificate inspections?

The Board may extend a power boiler’s certificate interval to two years when the boiler has internal continuous water treatment under the general supervision of a professional engineer experienced in boiler water. The owner must also keep records of every out-of-service period and chemical and physical analyses of boiler water samples taken at intervals of no more than 48 hours of operation. Plants that keep those records cleanly carry fewer annual outages.

Which boilers are exempt from the Maryland Boiler and Pressure Vessel Safety Act?

The Act exempts boilers under federal control, farm boilers used only for agriculture, heating boilers in private homes and in apartment houses with fewer than six family units, and small hot water supply boilers with a relief valve that stay within 200,000 Btu per hour, 210 degrees Fahrenheit and 120 gallons. Boilers in plants, hospitals, schools, offices and larger apartment buildings are covered and inspected.

Does a plant need a Maryland boiler operator license holder on duty when a repaired boiler restarts?

Steam plants generating more than 15 psi at 30 horsepower or more, and hot water boilers above 160 psig or 250 degrees Fahrenheit, are operated by individuals holding the Maryland stationary engineer license at the grade that matches the plant’s horsepower. The plant’s license holder takes the unit back after the repair, and Paul Industries runs the startup, combustion setup and safety device checks with that engineer present.

Which grade of the Maryland stationary engineer license fits a 300 horsepower plant?

A plant of 300 to 499 horsepower calls for a Grade 2 license. Grade 1 covers 500 horsepower and more, Grade 3 covers 100 to 299 horsepower, and Grades 4 and 5 cover 30 to 99 horsepower, with Grade 5 limited to buildings not open for public use. Every grade requires a state examination. The grade matters to a repair because the license holder on shift controls lockout, handover and restart.

Where are the Maryland boiler regulations written down?

The Maryland boiler regulations are in COMAR 09.12.01, issued by the Board of Boiler Rules, with the governing statute at Public Safety Article sections 12-901 and following. COMAR adopts the ASME Boiler and Pressure Vessel Code for construction and the National Board Inspection Code for repairs and alterations, and sets inspection intervals, reporting deadlines and installation rules.

How does Maryland boiler registration work for a replacement unit?

The person installing a boiler gives the state notice at least 30 days before installation, or less under emergency circumstances. A boiler built outside Maryland is inspected during construction by a National Board commissioned inspector, the manufacturer’s data report is filed with the Chief Boiler Inspector through the National Board, and the first state certificate inspection of a boiler new to Maryland carries no charge. Paul Industries plans that sequence into the replacement schedule.

Does a burner retrofit need an MDE permit to construct?

A burner retrofit changes fuel-burning equipment, so MDE air rules apply unless an exemption fits. Units burning gas or No. 1 or No. 2 oil below 1,000,000 Btu per hour are exempt under COMAR 26.11.02.10, boilers from 1 to under 10 million Btu per hour can use MDE’s general permit to construct, and larger or different-fuel units need an individual permit. Paul Industries checks the existing permit before quoting.

Does Maryland BEPS change whether to repair or replace a gas boiler?

For covered buildings of 35,000 square feet or more, BEPS adds direct emissions standards from 2030 and net zero direct emissions by 2040, so a boiler’s remaining life is weighed against those dates. A repairable boiler in an exempt manufacturing building, or one with a decarbonization plan already set, still earns its repair. Paul Industries prices the repair and a replacement path side by side so the owner can decide with both numbers.

How much does it cost to replace a commercial boiler in Maryland, compared with a repair?

Replacement cost depends on capacity, boiler type, fuel, removal and rigging access, piping and electrical changes, controls, permits and the outage the building can tolerate, so it is usually many times the cost of a tube or burner repair. Paul Industries gives a budget range for replacement from comparable scope alongside a firm repair price, with the inspection and permit steps for each path listed.

How long does a commercial boiler last in Maryland service?

Service life depends far more on water treatment, cycling and maintenance than on the calendar. Boilers with steady loads, good feedwater chemistry and annual internal inspections run for decades with retubes and burner rebuilds along the way, while short-cycling and poor treatment shorten life sharply. Maryland’s inspection records give a clear history, and Paul Industries uses that history when advising on repair or replacement.

Who works on commercial boilers at Maryland schools and county buildings?

Paul Industries works on commercial boilers at Maryland schools, county buildings, state agencies and universities, pricing the work under the prevailing wage law where it applies. Public work of $250,000 or more is covered when a state unit contracts with state money, or when a county contracts with 25 percent or more state funding, and mechanical systems service contracts on public work have been covered since October 1, 2022.

Which tasks belong in boiler maintenance Baltimore facilities run between certificate inspections?

A sound program covers daily logs of pressure, temperature and water level, regular blowdown and low-water cutoff tests, water chemistry checks, annual combustion analysis and burner tuning, safety valve testing, and preparation for each internal inspection. Paul Industries runs that program under a service contract for Baltimore hospitals, apartment towers and plants, and the records it produces support a request for an extended inspection interval.

What must an owner do first after a boiler explosion in Maryland?

The owner or operator notifies the Chief Boiler Inspector by email and by telephone within 24 hours and leaves the boiler and the area undisturbed until an inspector has examined them, except where something must be moved to save a life. After the inspector releases the equipment, Paul Industries isolates the damaged unit, assesses it and prices the repair or replacement.

What information speeds up pricing for a Maryland boiler repair?

Send the boiler make, type, size and fuel, its Maryland and National Board numbers, the latest certificate inspection report, photos of the fault, the operating pressure and the outage window the building can accept. For burner work, add the air permit number. With that, Paul Industries plans the opening visit and returns a priced repair scope with parts, labor and testing shown separately.

Boiler down or flagged at inspection in Maryland?

Send the boiler make, size, Maryland and National Board numbers and the latest inspection report. Call 201-450-8280 or request a quote.