Paul Industries designs, builds and services ultrapure water systems in Hawaii, from reverse osmosis and electrodeionization trains to mixed bed polishing loops and boiler makeup demineralizers, for laboratories, power plants, the Kapolei refining district, hospitals and liquid-cooled data halls across Oahu and the neighbor islands. Hawaii feedwater ranges from soft to very hard within a single island, a growing share of industrial water on Oahu is recycled or will come from the sea, and every membrane, resin bed and filter cartridge arrives by ship. Paul Industries builds plants that handle all three and keeps them producing water to specification.

Request a quote or call 201-450-8280

Headquarters 256 Shore Drive, Kilmarnock, Virginia
Oahu hardness 25 to 300 ppm, varying with the pumps in service (BWS)
Recycled RO water Honouliuli facility, Ewa: 12 MGD design, RO water for industry (BWS)
Desalination Kalaeloa: 1.7 to 2.55 MGD seawater RO planned (BWS)
Refining Kapolei refinery 93,500 barrels a day (EIA, January 2026)
Reviewed November 2026

What does an ultrapure water system in Hawaii have to handle?

An ultrapure water system in Hawaii has to handle variable feedwater, an island supply chain for consumables, high electricity prices, and marine air around every outdoor tank and pipe rack. The treatment steps are the same as anywhere: pretreatment, reverse osmosis, electrodeionization or ion exchange, polishing, ultraviolet treatment, ultrafiltration where particles matter, and a recirculating distribution loop. The design choices around those steps change, because the feed may shift from one well field to another, the replacement resin may sit in a container on the ocean, and every pump runs on power that cost an industrial user 31.45 cents per kilowatt-hour on average in 2025, against 8.51 nationally (EIA).

The general engineering of ultrapure water, from resistivity and TOC specifications to loop materials, is laid out on the national ultrapure water systems page. The high-purity water systems in Hawaii page covers pharmaceutical water and the energy case for membrane generation. This page focuses on feedwater sources, island users and the practical design of ultrapure plants for Hawaii sites.

Does Hawaii have hard water? Feedwater for an ultrapure plant

Hawaii has both hard and soft water, depending on the island, the well field and even the pumps running on a given day. The Honolulu Board of Water Supply says water sources across Oahu may have hardness between 25 and 300 parts per million, and that hardness at a single address can change with the pumps in service. On the US Geological Survey scale the Board cites, that span runs from soft, under 60 parts per million, to very hard, over 180.

For an ultrapure water system, that variability matters more than the average. Reverse osmosis recovery, antiscalant dosing and softener sizing are all set by the hardest water the plant will see, and a system designed on one sample can scale its membranes the week the utility switches wells. Rainfall is Oahu’s primary water source for both streams and groundwater, according to the Board, and the islands’ rainfall varies widely too: Hilo’s normal is over 120 inches a year, Honolulu’s about 16.

Does Oahu have hard water everywhere on the island?

Oahu water hardness varies from place to place and from day to day, so no single number describes the island. Paul Industries designs Oahu ultrapure plants from a feedwater survey that takes several samples over time, asks the water supplier which sources serve the site, and sizes pretreatment for the hardest credible case. Online hardness or conductivity monitoring at the inlet lets the plant adjust antiscalant dosing and alert operators when the feed changes. Honolulu water hardness on a given day is a starting point for that survey, not the design basis.

Hawaii feedwater sources for an ultrapure water system
SourceWhere it appliesWhat it means for pretreatmentDesign response
Potable groundwater, OahuMost Oahu sites on the Board of Water Supply systemHardness from 25 to 300 ppm depending on the source in serviceSoftening or antiscalant sized for the hardest case; inlet monitoring
RO recycled waterIndustrial users served by the Honouliuli facility in EwaAlready membrane treated; lower hardness, but organic and microbial control neededSecond pass RO and EDI; UV and TOC monitoring; contract water quality limits
Desalinated seawater (planned)Campbell Industrial Park and Kapolei once Kalaeloa operatesLow hardness, with boron and post-treatment chemistry to account forBoron rejection in the second pass; pH and alkalinity matched to the train
Neighbor island municipal suppliesMaui, Kauai and Hawaii Island sitesVaries by county system and sourceSite-specific survey and pretreatment selection
Private wellsRural and agricultural sitesPossible brackish intrusion near the coastChloride monitoring; RO sized for higher dissolved solids

Recycled RO water from Honouliuli as an ultrapure feed

Recycled reverse osmosis water from the Board of Water Supply’s Honouliuli Water Recycling Facility is a ready-made first stage for ultrapure water in parts of Ewa and Campbell Industrial Park. The Board describes the facility, opened in August 2000, as the largest water recycling facility in Hawaii, designed to produce 12 million gallons a day, and it produces R-1 water for irrigation and RO recycled water for industrial uses.

Starting from RO water shortens the treatment train: a second pass of reverse osmosis followed by electrodeionization and polishing can reach high resistivity without the heavy softening a hard groundwater feed would need. The care points shift to organics and microbes, because recycled water carries a different organic profile than groundwater. Paul Industries adds UV oxidation where TOC limits are tight, specifies sanitizable storage and sets TOC and bacteria monitoring at the inlet so the plant knows when the supply changes.

Kalaeloa desalination and what it means for feedwater

The Kalaeloa Seawater Desalination Facility is the Board of Water Supply’s planned reverse osmosis plant in Campbell Industrial Park, designed for 1.7 to 2.55 million gallons of fresh water a day to serve Campbell Industrial Park, Kapolei Business Park and the Deep Draft Harbor. The Board reported in late 2025 that its pilot study, completed in May 2025, showed the membranes and post-treatment could meet the project’s water quality standards, and that the construction notice to proceed was anticipated in fall 2026.

How seawater desalination works, and what it changes downstream

Seawater desalination works by pushing pretreated seawater through reverse osmosis membranes at high pressure, leaving most dissolved salts behind in a concentrate stream, then adjusting the product water’s minerals and pH so it suits the distribution system. For an ultrapure plant downstream, desalinated water usually arrives softer than Oahu groundwater, but boron, which membranes reject less completely than most ions, and the post-treatment chemistry both need attention. Paul Industries designs second pass RO and ion exchange to handle boron where the end use cares about it, such as electronics or power generation water.

What is ultrapure water used for in Hawaii?

Ultrapure water in Hawaii is used for boiler makeup at power plants and the refinery, for laboratory analysis and research at universities, hospitals and government laboratories, for clean rinsing in specialty manufacturing, and increasingly for filling and topping up liquid cooling loops in data centers. Each use sets a different specification, so the right ultrapure water system starts from the end use, not from a resistivity number alone.

Ultrapure and high-grade water users in Hawaii and what each typically needs
UserTypical waterKey parametersSystem Paul Industries builds
Power generation boiler makeupDemineralized waterConductivity, silica, sodiumRO with mixed bed or EDI polishing, degasification, storage
Refinery boilers and process steamDemineralized waterConductivity, silica, hardness breakthroughSoftening or RO, demineralizers, condensate polishing
University and research laboratoriesASTM D1193 Type I and II reagent waterResistivity, TOC, bacteriaCentral RO and EDI with polishing loop to lab outlets
Hospital and clinical laboratoriesClinical laboratory reagent waterResistivity, bacteria, particlesRO, EDI and point-of-use polishers with sanitizable loops
Liquid-cooled data hallsDeionized fill water for coolant blendingConductivity, chloride, bacteriaCompact RO and DI skid with storage and transfer pump
Specialty manufacturing and electronicsUltrapure water to ASTM D5127 or SEMI F63 classesResistivity near 18.2 megohm-cm, TOC, particles, dissolved oxygenFull UPW plant with UV, ultrafiltration and continuous loop

Boiler makeup for power and refining on Oahu

Boiler makeup is a major high-purity water duty in Hawaii, because petroleum is the state’s primary energy source for electricity generation, according to the EIA, and steam plants need demineralized water to protect their boilers and turbines. The state’s single refinery at Kapolei, rated at 93,500 barrels per calendar day of crude distillation in the EIA’s January 2026 count, runs boilers and process steam that need treated makeup as well.

Paul Industries builds makeup systems for those duties: pretreatment and reverse osmosis, electrodeionization or mixed bed polishing, degasification, demineralized water storage with nitrogen or vent protection, and the transfer pumps and piping to the boiler house. Silica, sodium and conductivity analyzers at the outlet protect the steam cycle, and condensate polishing returns clean condensate to the system. Boiler-side work is covered on the boiler repair in Hawaii page.

Laboratories, hospitals and research computing

Laboratories, hospitals and research facilities in Hawaii need reagent water in steady, modest volumes at many outlets, which suits a central RO and EDI plant feeding a recirculating polishing loop. Point-of-use polishers then bring each lab bench to its own grade. Paul Industries designs the central plant, the loop and the outlets together so pressure, flow and velocity stay right at every point of use, and sanitization can reach the whole loop.

Research computing adds a newer user. Liquid-cooled racks, such as those used in dense research and colocation halls, are filled with coolant blended from deionized water to the cold plate maker’s specification, and a facility that tops up its loops regularly needs a dependable supply. Maui hosts a Department of Defense supercomputing center managed by the University of Hawaii, and Oahu hosts the state’s colocation halls. The fill water side is described on the data center liquid cooling in Hawaii page.

Ultrapure water vs deionized water for Hawaii users

Ultrapure water vs deionized water is a difference of degree and of control: deionized water has had its ions removed by ion exchange or EDI, while ultrapure water also has its organics, particles, bacteria and dissolved gases reduced to tightly specified limits and is held there in a continuously circulating loop. Many Hawaii users, such as boiler makeup and coolant fill, need high-grade deionized water, not full ultrapure water, and buying the right grade saves capital and power.

Paul Industries sizes each ultrapure water purification system to the real specification: a two-stage RO and EDI skid with storage for demineralized water users, and a full ultrapure plant with UV oxidation, polishing and ultrafiltration only where the end use demands it. Industrial deionized systems are covered on the industrial DI water systems page.

Membranes, resins and spares on an island

Membranes, resins, cartridge filters and UV lamps are the consumables that keep an ultrapure plant producing, and on an island they have to be planned, stocked and rotated. Every ultrapure train relies on reverse osmosis; Hawaii plants should therefore hold at least one spare set of membrane elements for the most critical array, a stock of prefilters and post-filters, spare UV lamps and sleeves, and the resin or EDI module plan the owner prefers.

Paul Industries designs plants with standard membrane and cartridge sizes, so one spare fits several positions, and with redundancy in the trains that matter so a membrane clean or resin change never stops production. Cleaning-in-place skids let membranes be cleaned on site instead of replaced, which extends their life and reduces how many spares an operator has to keep.

Materials and layout for salt air and tight sites

Materials for an ultrapure plant in Hawaii have to suit both the water and the air around it. Inside the loop, PVDF, polypropylene and electropolished stainless steel are chosen by the purity class and sanitization method. Outside it, stainless supports, coated frames, sealed analyzer enclosures and covered tank vents protect equipment from salt spray, and outdoor storage tanks are vented through filters so neither salt nor dust reaches the water.

Space is often tight. Plants at existing Honolulu facilities often have to fit into mechanical rooms or rooftop penthouses, so Paul Industries builds compact skids sized for the building’s doors and freight elevator and prefabricates and tests them before shipment. Stainless loop piping is built to ASME BPE where the end use calls for it, and storage vessels that fall under Hawaii’s boiler and pressure vessel rules are built to the ASME code edition those rules adopt.

RO concentrate, regeneration waste and drains

RO concentrate, resin regeneration waste and sanitization rinses are the wastewater streams of an ultrapure plant, and on an island where water and sewer capacity are both valued they deserve design attention. Concentrate from a well-run RO is mostly the feedwater’s own minerals at higher concentration, which makes it a candidate for reuse as cooling tower makeup or irrigation where its chemistry fits. Regeneration waste from ion exchange is acidic or caustic and is neutralized before discharge.

Paul Industries sizes neutralization tanks and controls, routes each stream to the sewer connection or reuse point under the discharge terms the county sets for the site, and meters the volumes so the owner can see how much water the plant consumes for each gallon of ultrapure product. Choosing EDI instead of regenerated ion exchange removes the chemical regeneration stream altogether, which simplifies permits and handling on many Hawaii sites.

Power use and efficiency in a Hawaii ultrapure plant

Power use in a Hawaii ultrapure plant comes mainly from high-pressure RO pumps, loop circulation pumps and UV lamps, all running continuously. Variable speed drives on RO and loop pumps, energy-efficient membranes, right-sized loop velocity and RO recovery set as high as the feedwater allows all cut the bill, and at Hawaii industrial rates those measures pay back faster than on the mainland. Paul Industries lists each option’s energy use with the design so the owner can compare installed and operating cost.

Water efficiency matters as well. RO concentrate can feed cooling towers or other non-potable uses where chemistry allows, and on Oahu the plant’s recovery rate is a design choice that affects both water purchases and the volume sent to drain. Reverse osmosis Oahu plants on recycled or desalinated feed can often run higher recovery than on hard groundwater.

Monitoring, maintenance and records

Monitoring is what keeps an ultrapure plant on specification between service visits, and in Hawaii it also gives early warning of feedwater changes. Paul Industries fits inlet conductivity and hardness or chloride monitoring, RO permeate conductivity and recovery, EDI or polisher outlet resistivity, TOC and, where the end use needs them, particle counters and dissolved oxygen analyzers. Data goes to the plant controls and, where the owner wants it, to remote alarms.

Maintenance schedule for a Hawaii ultrapure water plant
TaskTypical intervalWhy it matters in Hawaii
Review inlet and permeate trendsWeeklyCatches a change in well field or supply before membranes scale
Prefilter and cartridge changesBy pressure drop, often monthlyProtects membranes; stock held on site for an island plant
RO membrane cleaningWhen normalized flow or rejection drifts past set limitsCleaning on site extends membrane life and reduces spares needed
UV lamp replacementPer lamp rated hours, commonly annuallyWarm water favors bacteria; UV performance must be maintained
Loop sanitizationPer the defined regime and bacteria resultsWarm buildings and ambient loops need disciplined sanitization
Analyzer calibrationQuarterly or per makerRecords support lab, power and warranty requirements
Corrosion inspection of skids and supportsSemiannuallySalt air attacks frames, fasteners and enclosures

Every service visit ends with a written report and updated trends, and the records are kept in the format the user’s quality system or the plant’s operating permit expects.

Startup, sanitization and turnover

Startup of a new ultrapure plant runs from flushing and leak testing through membrane loading, resin conditioning and initial sanitization to a stable run on specification, and in Hawaii it includes a check of the feedwater against the design basis on the actual supply. Paul Industries runs the system until outlet quality has held steady, sanitizes the loop, verifies each point of use and records the results.

Turnover delivers as-built drawings, operating and maintenance manuals, analyzer calibration records, the startup data, the spares list and operator training on normal operation, cleaning, sanitization and alarm response. For regulated laboratories and clinical users, the records are prepared to suit the user’s own qualification program.

What does an ultrapure water system cost in Hawaii?

The cost of an ultrapure water system in Hawaii depends on the flow and the purity class, the feedwater source and its variability, the number of trains and the redundancy, the loop length and outlets, the materials, the building and access, and freight. A demineralized water skid for boiler makeup and a full ultrapure plant for a laboratory building differ in scope by an order of magnitude, so a single price would mislead.

Operating cost belongs in the same comparison, including power, consumables, chemicals and water. Paul Industries offers a budget range from comparable systems once it has the flow, specification and feedwater data, prices options for redundancy and efficiency, and fixes the price once the design is settled.

Who installs ultrapure water systems in Hawaii?

Paul Industries installs ultrapure water systems in Hawaii, designing and building RO, EDI, ion exchange, polishing, UV and ultrafiltration trains with their storage and distribution loops for power and refining, laboratories, hospitals, research computing and manufacturing on Oahu, Maui, Kauai and Hawaii Island. Work covers feedwater surveys, design, prefabrication, installation, startup, operator training and service.

Clean process piping to the points of use is covered on the process piping in Hawaii page and controlled environments on the cleanrooms in Hawaii page. Owners comparing state programs can read the ultrapure water systems in California page, where feedwater and seismic rules differ, and the West Coast page for wider Pacific work.

Ultrapure water from Paul Industries across Hawaii

Ultrapure water projects in Hawaii are offered by Paul Industries three ways: tested skids crated with their spares for the owner to set, one design-build price for engineering and construction, or full installation to an engineer’s existing drawings, each backed by service contracts for membranes, resins, analyzers and sanitization. The company’s Kilmarnock, Virginia headquarters at 256 Shore Drive also anchor its ultrapure water systems in Virginia work, and Paul Industries takes water treatment projects on every Hawaiian island, throughout the United States and abroad, with more island plant services on the Hawaii page.

To begin, share the end use and specification, the flow and peak demand, recent feedwater analyses and the site, or request a quote.

Standards referenced: ASTM D1193 (reagent water) · ASTM D5127 (electronics and semiconductor water) · SEMI F63 · USP Purified Water · ASME BPE · ASME B31.3 · ASME Boiler and Pressure Vessel Code (2021 edition as adopted in Hawaii) · Hawaii Boiler and Elevator Safety Law and HAR Title 12, chapters 220 to 225.1

Frequently asked questions

Who installs ultrapure water systems for laboratories and plants in Honolulu?

Paul Industries installs RO, EDI and polishing systems for laboratories, hospitals and plants in Honolulu and across Oahu, with recirculating loops to every point of use. Systems are prefabricated and tested before shipment and sized for the building’s access. Share the end use, flow, specification and a feedwater analysis, and Paul Industries returns a design concept and budget.

Does Paul Industries build demineralized water systems in Kapolei and Campbell Industrial Park?

Paul Industries builds demineralized and ultrapure water systems for industrial users in Kapolei and Campbell Industrial Park, including boiler makeup for steam and power users. Plants there may draw on potable supply, recycled RO water from the Honouliuli facility or, once operating, desalinated water from Kalaeloa. Pretreatment is designed for the source that serves the site.

Can a neighbor island lab or hospital on Maui, Kauai or Hawaii Island get a central ultrapure plant?

Paul Industries builds ultrapure and deionized water systems on Maui, Kauai and Hawaii Island, for laboratories, hospitals, research computing and industrial users in places such as Kahului, Lihue, Hilo and Kona. Each county system and source differs, so every design starts with a feedwater survey. Skids, spares and consumables ship together for neighbor island sites.

Does Honolulu have hard water, and does it matter for an ultrapure system?

Honolulu’s tap water can range from soft to very hard, since the Board of Water Supply reports hardness between 25 and 300 parts per million across Oahu sources, varying with the pumps in service. For an ultrapure system that range matters, because RO scaling and softener sizing follow the hardest water the plant will see. Paul Industries designs pretreatment for the worst credible case.

Can recycled water from the Honouliuli facility feed an ultrapure water system?

Recycled RO water from the Board of Water Supply’s Honouliuli facility in Ewa is a strong starting point for ultrapure water, since it is already membrane treated. A second RO pass, EDI and polishing can follow, with UV oxidation and TOC and bacteria monitoring to manage the organic and microbial profile. Paul Industries designs the train around the recycled supply’s water quality data.

When will Kalaeloa desalinated water be available to Campbell Industrial Park users?

The Board of Water Supply reported in late 2025 that design was nearing completion, permitting was under way, and the construction notice to proceed was anticipated in fall 2026 for the 1.7 to 2.55 million gallon a day Kalaeloa plant. Users planning ultrapure systems in the area can design pretreatment flexible enough to run on current potable supply and on desalinated water later.

What is ultrapure water used for at Hawaii power plants?

Power plants use demineralized and ultrapure water as boiler and steam cycle makeup, where low conductivity, silica and sodium protect boilers and turbines from scale and corrosion. Petroleum is Hawaii’s primary energy source for generation, according to the EIA, so steam plants remain important users. Paul Industries builds RO, EDI or mixed bed makeup systems with degasification and outlet analyzers.

What is the difference between ultrapure water vs deionized water for a Hawaii lab?

Deionized water has had its ions removed, while ultrapure water also has organics, particles, bacteria and dissolved gases reduced to tight limits and is held in a circulating loop. Many lab uses need ASTM D1193 Type II water, with Type I polished at the bench. Paul Industries sizes a central system to the real need and adds point-of-use polishers where Type I is required.

What water should fill a liquid cooling loop at a Hawaii data center?

A liquid cooling loop should be filled with deionized or RO water blended with the inhibitor or glycol the cold plate maker specifies, never tap water, since Oahu hardness varies widely by source. Paul Industries supplies compact RO and DI skids with storage and transfer pumps so the data hall has a dependable supply for initial fill and later top-ups.

How does boron in desalinated water affect an ultrapure plant?

Boron passes reverse osmosis membranes more readily than most ions, so desalinated water can carry more boron than its low hardness suggests. For power generation and electronics uses where boron matters, the ultrapure train needs a second RO pass at suitable pH or boron-selective ion exchange. Paul Industries checks boron in the feedwater data and designs for it.

How many spare membranes should a Hawaii ultrapure plant keep?

A Hawaii ultrapure plant should hold at least one spare set of elements for its most critical RO array, along with prefilters, post-filters, UV lamps and the resin or EDI module plan the owner prefers. Standard element sizes across the plant let one spare fit several positions. Paul Industries builds the spares list into the design and the turnover documents.

Which materials hold up for ultrapure water equipment in Hawaii's salt air?

Inside the loop, PVDF, polypropylene and electropolished stainless steel are chosen by purity class and sanitization method. Outside it, stainless supports, coated skid frames, sealed analyzer enclosures and filtered tank vents protect against salt spray and dust. Paul Industries specifies both sets of materials for each site’s exposure.

How is an ultrapure water loop sanitized in a warm Hawaii building?

A loop in a warm building favors bacterial growth, so continuous circulation at velocity, no dead legs and a defined sanitization regime are essential. Hot water, ozone or chemical sanitization are chosen by the loop materials and the end use, with UV treatment in the loop and bacteria and TOC monitoring. Paul Industries designs the loop so sanitization reaches every outlet.

Do storage tanks for an ultrapure system in Hawaii need a state permit?

Hawaii’s boiler and pressure vessel program, run by the HIOSH Boiler and Elevator Inspection Branch, covers pressure vessels and pressure systems, so pressurized filter housings, hydropneumatic tanks and similar vessels are checked against it. Paul Industries reviews every tank and vessel during design, identifies the ones the rules cover, and supplies them built to the ASME code edition the rules adopt.

How can a Hawaii ultrapure plant cut its power use?

Variable speed drives on RO and loop pumps, energy-efficient membranes, loop velocity sized to the real demand and RO recovery set as high as the feedwater allows all reduce power use. At Hawaii’s 2025 industrial average of 31.45 cents per kilowatt-hour, those measures pay back quickly. Paul Industries prices each option with its energy use alongside the base design.

Can Paul Industries supply an ultrapure water skid for Hawaii without installing it?

Paul Industries supplies RO, EDI, polishing and DI skids for Hawaii projects as supply-only packages, factory tested and crated with drawings, manuals and a spares kit. The same systems are offered with design-build or complete installation, startup and operator training. Service contracts cover membranes, resins, analyzers and sanitization afterward.

What should a Hawaii owner send to price an ultrapure water system?

Share the end use and the water specification, the average and peak flow, the number and location of outlets, recent feedwater analyses or the supplier serving the site, the building and space available, and any existing equipment. Paul Industries returns a budget range from comparable systems and then a firm price once the design is settled.

Planning ultrapure water for a Hawaii lab, plant or data hall?

Share the end use, specification, flow, outlets and recent feedwater analyses for the site. Call 201-450-8280 or request a quote.