Paul Industries provides boiler repair in Michigan for manufacturing plants, refineries, hospitals, universities and commercial buildings, working to Article 9 of the Skilled Trades Regulation Act, the Michigan Boiler Rules and the 2019 National Board Inspection Code. Paul diagnoses the failure, sets up the repair permit with the state Boiler Division or Detroit’s building department, makes the mechanical or welded repair, tests the controls to ASME CSD-1 and hands back a boiler ready for its certificate inspection. Paul Industries is headquartered in Kilmarnock, Virginia, and takes boiler work across Michigan and the rest of the Midwest.

Request a quote or call 201-450-8280

Headquarters 256 Shore Drive, Kilmarnock, Virginia
Michigan boiler law Skilled Trades Regulation Act, Article 9 (MCL 339.5901 to 339.5947)
Certificate intervals Power and process: 1 year; low-pressure steam: 2 years; hot water: 3 years
Repair code NBIC 2019 edition under the Michigan Boiler Rules (R 339.5203, May 2023)
Detroit Article 9 excludes cities of 600,000 or more; the city's BSEED inspects boilers
Reviewed November 2026

What does boiler repair in Michigan involve under Article 9?

Boiler repair in Michigan is regulated by Article 9 of the Skilled Trades Regulation Act, 2016 PA 407, which took effect on April 4, 2017 and carried forward the board of boiler rules that the Michigan Boiler Act of 1965 had created. The Bureau of Construction Codes inside the Department of Licensing and Regulatory Affairs (LARA) runs the Boiler Division, and Executive Reorganization Order 2024-2 transferred the board to LARA and abolished it as a separate body. The working rules are the Michigan Boiler Rules, Part 9 of the administrative code, revised with an effective date of May 3, 2023.

The Michigan boiler law sorts equipment in a way that decides almost everything about a repair. A power boiler generates steam or vapor above 15 psig. A process boiler is one that sends more than 10 percent of its capacity to direct steam humidification or direct process work, a definition that pulls many plant boilers out of the heating category even when they run at modest pressure. Water boilers become high pressure, high temperature units once they exceed 160 psig or 250 F. Low pressure boilers are steam boilers at 15 psig or less and hot water heating boilers within the 160 psig and 250 F limits.

The category sets the inspection clock, the permit route and whether the National Board accreditation program applies to the repair. Before Paul Industries prices a Michigan job, the boiler’s category is confirmed from the nameplate, the manufacturer’s data report and the current inspection certificate posted in the boiler room.

How often do boilers need to be inspected in Michigan?

Section 943 of the act, as amended in September 2020, sets three certificate inspection intervals in Michigan: annual for power, process and high temperature water boilers, every two years for low pressure steam or vapor heating boilers, and every three years for hot water heating and hot water supply boilers. Power, process and high temperature water boilers also get an external inspection under pressure within six months of each certificate inspection. A two-month grace period applies between certificate inspections.

Michigan boiler categories and their certificate inspections
Boiler categoryDefined byCertificate inspectionCertificate valid for
Power boilerSteam or vapor above 15 psigAnnually, plus an external inspection under pressure within 6 months12 months, plus the 2-month grace period
Process boilerMore than 10% of capacity used for direct humidification or process workAnnually, plus the 6-month external inspection12 months
High pressure, high temperature water boilerAbove 160 psig or 250 FAnnually, plus the 6-month external inspection12 months
Low pressure steam or vapor heating boilerSteam at 15 psig or lessEvery 2 years24 months
Hot water heating or supply boiler160 psig or less and 250 F or lessEvery 3 years36 months
Rental boilerTemporary installationBefore it is rented, approved for temporary use12 months

Plants with strong programs can stretch the internal inspection. Under R 339.5214 the state may approve a 24-month internal inspection interval when the plant documents operator training, maintenance, water chemistry, operating limits, chemical cleaning, protective devices and relief valve testing, and a review committee that includes the inspector meets within 30 days after each internal inspection. Power boilers already on a 24-month cycle may apply for 36 months. A repair that changes the boiler’s condition is reported to that committee, so Paul Industries writes repair reports that slot into the plant’s extension file.

Michigan boiler inspection requirements that shape a repair

Michigan boiler inspection requirements matter to a repair because the inspector, the certificate and the repair permit are linked. A certificate inspection is internal wherever the boiler’s construction allows. The inspector files the report within 30 days, LARA issues a certificate stating the maximum pressure the boiler may run at, and the owner posts that certificate under glass in the boiler room.

A boiler inspection state of Michigan rules recognize is made by the chief inspector, a deputy inspector employed by LARA, or a special inspector. Special inspectors are issued to inspectors who work full time for a boiler insurer, for a city with its own boiler inspection department, or for an owner whose inspection service is supervised by registered professional engineers on its payroll. Whichever boiler inspector Michigan assigns to a plant, that person also accepts the repair method before welding on a power boiler begins.

Since the 2020 amendment, running a boiler without a valid certificate, or above the pressure printed on it, is a misdemeanor carrying a fine of up to $500, up to 60 days in jail, or both, and each day counts as a separate offense. The chief inspector may also suspend a certificate when a boiler cannot run safely. When an inspection turns up a cracked tube sheet, wasted stays or a failed low water cutoff, the repair has a legal deadline as well as an engineering one.

When does a boiler repair need a permit in Michigan?

A boiler repair in Michigan needs a permit to repair from the Boiler Division before work starts, under section 941 of the act, unless an inspector has authorized the repair pending the permit. Installing or altering a boiler needs a separate permit to install or alter under section 939. A boiler permit Michigan issues for welded work also covers the boiler external piping and the non-boiler external piping that the rules treat as part of the installation.

R 339.5210 spells out the piping side: installing, repairing or replacing welded pipe needs a permit, installing nonwelded pipe does not, and changing a boiler’s use, for example from low pressure steam to hot water heating, needs a permit as well. For welded repairs to power boilers and high temperature water boilers, the Michigan boiler regulations make the National Board accreditation program mandatory: the repair is made under the National Board R program, with the inspector consulted on the method before the work and accepting it after. Alterations to any boiler that the rules do not exempt follow the same program.

Common Michigan boiler repairs and the paperwork each one sets off
RepairState paperworkCode basisWhat the owner keeps
Tube replacement or retube, power boilerPermit to repair; inspector accepts the method firstNBIC Part 3, R program, ASME Section INBIC R-1 report, weld procedure and welder records, test record
Weld repair to a shell, furnace or tube sheetPermit to repair; copy of the permit and the NBIC report to the Boiler Division on completionNBIC, ASME Section IX procedures filed before weldingR-1 report, NDE results, hydrostatic test record where the inspector asks for one
Rerate or other change in maximum allowable pressurePermit to alter; counts as an alteration even with no physical changeNBIC alteration rules, ASME edition of constructionR-2 report, revised nameplate data, new certificate pressure
Welded boiler external or non-boiler external pipingPermit for welded pipeASME B31.1-2018, or B31.3-2019 at chemical plants and refineriesWeld map, test record, permit closeout
Burner, flame safeguard or control replacementNo pressure-part permit; CSD-1 testing evidence for the next inspectionASME CSD-1, 2018 editionSigned control test report with set and trip points
Safety valve replacement or repairRecorded for the inspector; capacity and set pressure checked against the certificateNBIC, National Board VR program for valve repairsValve data, set pressure and capacity record

Welding procedures carry their own Michigan step. R 339.5216 requires the welding procedure specifications and procedure qualification records, qualified to ASME Section IX, to be filed with the Boiler Division before any welding on a boiler, and the welder performance qualifications to be available for the inspector at the work site. Paul Industries assembles that package during planning, so the inspector’s review is finished before the boiler comes down. The welding side of that work is explained further on the page for industrial welding services in Michigan.

CSD-1 testing and the Michigan control report

The Michigan Boiler Rules adopt ASME CSD-1, 2018 edition, for the controls and safety devices on automatically fired boilers, and R 339.5206 requires the owner to show the inspector proof of that testing at each certificate inspection. The proof is a dated, signed service report or checklist listing every control and safety device, its manufacturer and model number, its set point and the point at which it actually operated during the test. If the evidence is missing, the inspector may issue a certificate for a shorter term than the act allows.

That report is what people mean by the CSD 1 boiler inspection form Michigan inspectors ask for. Hot water heating and supply boilers with an input of 400,000 Btu per hour or less are tested once per inspection cycle, within the 12 months before the certificate inspection. The rules also require daily, weekly and monthly operating checks to be done and written down according to the manufacturer’s instructions, with CSD-1 nonmandatory Appendix D as the fallback checklist, and they require the manually operated remote shutdown switch that CSD-1 calls for.

Controls a CSD-1 test report covers on a typical Michigan boiler
DeviceHow it is testedWhat the report records
Primary and auxiliary low water cutoffsWater level lowered under firing conditions until the burner tripsLevel and response at trip, manual reset confirmed where required
Operating and high limit controlsSetpoint lowered or temperature and pressure raised until the limit actsSet point against actual trip point
Flame safeguardFlame failure simulated during firingFlame failure response time, lockout and purge sequence
Low and high gas pressure switchesGas pressure moved past each settingSet and trip pressures
Safety shutoff valvesClosure and seat leakage testResult of the valve leak test
Combustion air proving and remote shutdown switchAir flow interrupted; switch operated at the boiler room exitBurner shutdown confirmed for each

A control replacement made during a repair is tested before the boiler goes back on line, and the results are added to the plant’s CSD-1 file. Paul Industries leaves the test sheet with the boiler log, so the next inspector finds the evidence the rule asks for.

Boiler repair, Detroit, MI: where Article 9 stops at the city line

Section 947 of the act states that Article 9 does not apply in any city with a population of 600,000 or more at the latest decennial census, and Detroit, with 639,111 residents in 2020, is the Michigan city above that line. Boiler permits, licensing and inspections inside Detroit therefore run through the city’s Buildings, Safety Engineering and Environmental Department (BSEED), whose construction inspection division has a boiler trade team and lists permit, annual and special boiler inspections.

The practical consequence is that a company with plants in Detroit and in Dearborn, Warren or Livonia deals with two inspection systems a few miles apart. Boiler service Detroit facilities receive follows the BSEED inspection and certificate of acceptance process, while a plant across the city boundary files with the state Boiler Division. Paul Industries confirms which authority covers the address before the repair is scheduled and prepares the matching permit and closeout documents.

Power and process boilers at Michigan plants

Michigan’s process industries keep a large population of power and process boilers on the annual cycle. Dow is headquartered in Midland, where its main plant sits on the Tittabawassee River; Marathon Petroleum runs a refinery in Detroit; Pfizer CentreOne describes its Kalamazoo operation as the largest site in its manufacturing network; and food plants in Battle Creek, Fremont and Grand Rapids rely on steam for cooking, sterilizing and cleaning. These facilities are named only to describe the market.

Plant boilers also bring piping into the repair. R 339.5209 requires blowoff piping beyond the second valve, steam piping out to the load, feedwater piping from the pump and condensate piping to be built to ASME B31.1, and it lets chemical plants and refineries use ASME B31.3 instead. A tube failure that traces back to a failed condensate return or a feedwater problem is repaired at the source as well as in the boiler, and the related lines are covered on the process piping in Michigan page. Feedwater conditioning ahead of the boiler is described under deaerators and boiler water treatment.

Long-running plants also lean on the extension rules described above. A repair planned for the internal inspection window, rather than forced by a trip, keeps steam available and keeps the plant’s 24 or 36-month approval intact.

Boiler repair across Michigan’s regions

Paul Industries takes boiler repair work across the Lower Peninsula and the Upper Peninsula, and the mix of boilers changes from one region to the next.

Oakland and Macomb counties, Ann Arbor and Jackson

The suburban counties around Detroit hold automotive plants, engineering campuses, hospitals and office parks, mostly on the state system rather than Detroit’s. Ann Arbor’s university and hospital campus runs central steam, and Jackson’s manufacturers run process boilers for plating, washing and heat treating. Low pressure heating boilers on the two-year cycle and hot water boilers on the three-year cycle are common in this building stock, and their CSD-1 reports are where inspection findings tend to begin.

Boiler repair, Lansing and mid-Michigan

Boiler repair in Lansing covers state office buildings, the Michigan State University campus in East Lansing, hospitals and assembly plants. Government and university buildings often fall under public contracts, which brings prevailing wage and public bidding into the repair, as explained in the cost section below.

Boiler repair, Grand Rapids, Kalamazoo and West Michigan

West Michigan’s furniture, food, medical device and pharmaceutical plants run a wide range of firetube and watertube boilers, from packaged units serving process lines to large boilers at Kalamazoo and Portage drug and device sites. Clean steam generators and the plant boilers feeding them often share an outage, which Paul Industries schedules together.

Midland, Bay City, Flint, Traverse City and the Upper Peninsula

The Great Lakes Bay region’s chemical plants run large power boilers with long histories of repairs and rerates, so the manufacturer’s data report and every earlier R-1 and R-2 report are pulled before a new repair is designed. Flint and Saginaw manufacturing, Traverse City food processing and Upper Peninsula paper, mining and institutional plants complete the picture, with the hardest winter conditions in the state on the northern sites.

Air permits when a burner or boiler changes in Michigan

EGLE’s Rule 201 requires a permit to install before a person installs, reconstructs, relocates or modifies process equipment that may emit an air contaminant, and boiler replacements are measured against it. Rule 282 exempts fuel-burning equipment used for space heating, service water heating, power generation or indirect heating that burns only sweet natural gas, synthetic natural gas or liquefied petroleum gas at a rated heat input of 50 million Btu per hour or less.

A like-for-like tube or refractory repair does not change emissions, so the question rarely arises on a simple repair. Boiler repair or replacement decisions are different: a larger burner, a fuel change, a dual-fuel conversion or a boiler that serves a source with an existing permit needs to be checked against Rule 201, the exemption rules and any conditions in the plant’s current permit before equipment is ordered. Paul Industries flags that question in the replacement study.

Replacing a Michigan boiler instead of repairing it

A new boiler in Michigan is installed under a permit to install from the Boiler Division and is inspected during construction by an inspector holding a Michigan license, or, for boilers built in another state, by an inspector holding an equivalent state license or a National Board commission. Cast iron sectional boilers are excused from the shop inspection. The Michigan boiler code then adopts the 2019 ASME Boiler and Pressure Vessel Code sections and B31.1-2018 for construction, and the manufacturer’s data report is filed with the state.

Two Michigan rules affect the decision directly. Boilers in service before December 31, 1998 may not have their maximum allowable working pressure recalculated under ASME editions published after 1998, so a rerate that would have helped an older boiler is often unavailable. Secondhand boilers that change owner and location are treated under the rules for new construction, which makes a used boiler a bigger paperwork project than buyers expect. Paul Industries prices both routes, a repair that keeps the existing boiler and a replacement that brings a new certificate, and sets them side by side with steam demand, efficiency and the remaining life of the pressure parts.

Steam distribution often decides the answer as much as the boiler does. Leaking traps and failed condensate return raise makeup water and fuel use whatever the boiler’s condition, which is why the repair study also looks at steam traps and return lines.

How much does boiler repair in Michigan cost?

The cost of boiler repair in Michigan depends on the boiler category, the repair type, the access to the pressure parts and the outage window more than on the boiler’s size. A control or burner repair on a heating boiler is priced in labor hours and parts. A retube or a welded shell repair on a power boiler adds the permit, the National Board reporting, nondestructive examination, a hydrostatic test where the inspector asks for one, and refractory, insulation and lagging work around the opening.

Other cost drivers are specific to Michigan sites. Winter outages need temporary heat or a rental boiler, which must itself be inspected before it is rented and carries a 12-month certificate. Detroit work runs through BSEED rather than the state. Public projects can carry Michigan’s prevailing wage: 2023 PA 10, effective February 13, 2024, requires contracts for state projects to pay the wage and fringe rates set by the Department of Labor and Economic Opportunity, and those rates appear in the bid documents. Paul Industries gives a budget range once the boiler data and inspection report are in hand, then a firm price when the scope and outage dates are fixed.

Who repairs boilers in Michigan?

Paul Industries repairs boilers in Michigan, from packaged firetube heating boilers in office buildings to watertube power and process boilers at chemical, pharmaceutical, food and refining plants. Paul diagnoses trips and leaks, replaces tubes and retubes firetube boilers, makes weld repairs under the National Board program, rebuilds burners and controls, replaces safety valves, repairs refractory, and installs replacement boilers with their piping and controls.

Plant engineers comparing steam boiler repair companies in Michigan usually check the same points: the Article 9 permit and the National Board report on every welded repair, welding procedures filed with the Boiler Division before work starts, CSD-1 records the next inspector will accept, and a single contract that covers the boiler, its piping and its controls. For boiler repair, Michigan owners get all of them from Paul Industries under one schedule and one set of records. For the national scope of the service, see boiler repair; for other Michigan work, see the Michigan service area page.

What Paul Industries repairs on Michigan boilers

Paul Industries, headquartered at 256 Shore Drive in Kilmarnock, Virginia, delivers boiler repair in Michigan as diagnosis, repair, testing and turnover under one contract. Paul handles emergency repairs after a trip, planned outage repairs timed to the inspection cycle, repair or replacement studies, and replacement boilers delivered complete with burner, controls, feedwater and blowdown equipment and piping. The same approach runs at Paul’s boiler repair in Virginia, its headquarters state, and on Pennsylvania boiler repair and New York boiler repair projects. Pressure vessels on the same steam system are covered on pressure vessel fabrication in Michigan, and the chilled water side of a central plant on chiller repair in Michigan. To start, request a quote with the boiler data and the latest inspection report.

Standards referenced: Michigan Skilled Trades Regulation Act, Article 9 (MCL 339.5901 to 339.5947) · Michigan Boiler Rules, R 339.5201 et seq. · National Board Inspection Code, 2019 edition · ASME Boiler and Pressure Vessel Code, Sections I, IV and IX · ASME B31.1 Power Piping · ASME B31.3 Process Piping · ASME CSD-1 · EGLE Rule 201 permit to install (R 336.1201) · Michigan prevailing wage act, 2023 PA 10

Frequently asked questions

Who handles boiler repair, Detroit plants and Wayne County hospitals included?

Paul Industries repairs boilers in Detroit and across Wayne County, at manufacturing plants, hospitals, schools and commercial buildings. Inside Detroit, the city’s Buildings, Safety Engineering and Environmental Department handles boiler permits and inspections because Article 9 does not apply in cities of 600,000 or more. Outside the city, the state Boiler Division does. Paul prepares the permit and closeout records for whichever authority covers the address.

Who provides boiler repair, Grand Rapids to Kalamazoo and the rest of West Michigan?

Paul Industries repairs boilers in Grand Rapids, Holland, Kalamazoo, Portage and Battle Creek, at food, furniture, medical device and pharmaceutical plants as well as hospitals and campuses. West Michigan sites often pair plant boilers with clean steam generators, and Paul plans both into one outage. Send the boiler data plate photos and the last inspection report to start.

Who repairs boilers for plants in Midland, Bay City and the Great Lakes Bay region?

Paul Industries repairs power and process boilers at chemical and manufacturing plants around Midland, Bay City and Saginaw. These boilers often carry decades of repairs and rerates, so Paul starts by gathering the manufacturer’s data report and every earlier National Board R-1 and R-2 report. The new repair is then designed against the real history of the pressure parts rather than the nameplate alone.

Who counts as a boiler inspector Michigan law accepts for a certificate inspection?

Section 943 lists three: the chief inspector, a deputy inspector employed by LARA, and a special inspector. Special inspectors work full time for a boiler insurer, for a city with its own inspection department, or for an owner-user whose inspection service is supervised by registered professional engineers. Each holds a Michigan inspector license or qualifies through an equivalent state license or a National Board commission.

What do the Michigan boiler rules adopt for repair and construction work?

The rules effective May 3, 2023 adopt the 2019 National Board Inspection Code for inspection, repair and alteration; the 2019 ASME Boiler and Pressure Vessel Code sections, including I, IV, VIII and IX, for construction; ASME B31.1-2018 for boiler and non-boiler external piping, with B31.3-2019 allowed at chemical plants and refineries; and ASME CSD-1, 2018 edition, for controls and safety devices.

Is a boiler permit needed in Michigan before a tube replacement?

A tube replacement is a repair to a pressure part, so section 941 requires a permit to repair from the Boiler Division before work starts, unless an inspector authorizes the repair pending the permit. On power and high temperature water boilers the work follows the National Board R program, with the inspector accepting the method beforehand and the completed repair afterward. Paul Industries files the permit during planning.

What goes on the CSD-1 report a Michigan inspector asks to see?

R 339.5206 asks for a dated and signed service report or checklist that lists each control and safety device tested, its manufacturer, its model number, its set point and the actual point at which it operated. Low water cutoffs, limit controls, flame safeguards, gas pressure switches, safety shutoff valves and the remote shutdown switch all belong on it. Missing evidence can shorten the certificate term.

Can a Michigan boiler keep running after its certificate expires?

Section 943 allows a two-month grace period between certificate inspections, and the certificate stays valid during that grace period. Beyond it, section 946 makes operating a boiler under pressure without a valid certificate a misdemeanor, with fines of up to $500, up to 60 days in jail, or both, and each day counted separately. Repairs that block an inspection are scheduled with that deadline in view.

Can a Michigan power boiler go 24 or 36 months between internal inspections?

R 339.5214 lets the state approve a 24-month internal inspection interval for utility and industrial boilers whose owners document training, maintenance, water chemistry, operating parameters, chemical cleaning, protective devices and relief valve testing. A review committee including the inspector meets within 30 days after each internal inspection. Power boilers already on 24 months may apply for 36, and repair reports feed that committee’s review.

Which boilers does the Michigan boiler law leave out?

Section 915 exempts boilers under federal control, boilers in highway vehicles, boilers used solely for agricultural purposes, boilers on farms used for mint processing, hobby steam engines and miniature hobby locomotives, and low pressure steam and hot water boilers in private homes or apartment buildings with fewer than six families. Boilers in larger apartment buildings, commercial buildings and plants are covered.

Does a Michigan boiler operator need a state registration?

Section 931 allows an individual to operate a boiler and its auxiliaries without a state registration, but only registered individuals may use titles such as registered boiler operator or first-class stationary engineer. Registrations are graded by the boiler heating surface in the plant, with breaks at 4,000, 7,500 and 20,000 square feet. Many plants and insurers still set their own operator requirements.

How is a rental boiler handled during a Michigan repair outage?

R 339.5219 requires a rental boiler to be inspected before it is rented and approved for temporary installation, and its inspection certificate is valid for 12 months. Paul Industries plans the temporary connection, the fuel and water supply and the controls so the rental unit carries the load while the permanent boiler is repaired, then removes it once the repaired boiler is tested and back on line.

Does a burner replacement need an EGLE air permit in Michigan?

Rule 201 requires a permit to install before process equipment that may emit air contaminants is installed or modified. Rule 282 exempts gas-fired equipment for space heating, service water heating, power generation or indirect heating at 50 million Btu per hour or less. A like-for-like gas burner usually stays inside that exemption, while a larger unit, another fuel or a permitted source needs a closer review.

Is boiler work on a Michigan state project paid at prevailing wage?

Michigan restored prevailing wage with 2023 PA 10, effective February 13, 2024. Contracts for state projects that employ construction mechanics must pay at least the wage and fringe rates the Department of Labor and Economic Opportunity determines for the area, and the rate schedule is printed in the bid documents. Paul Industries prices public boiler work at the scheduled rates.

How much does a retube cost compared with a new boiler in Michigan?

The answer depends on the boiler’s age, its shell and tube sheet condition, the tube count and the fuel savings a new boiler would bring. A retube keeps the existing certificate history but adds permit, National Board reporting and testing costs. A new boiler adds the install permit, foundation, stack and piping work, and Michigan’s limit on recalculating pressure for pre-1999 boilers often tips older units toward replacement.

Which records reach the Boiler Division after a welded repair in Michigan?

R 339.5210 requires a copy of the approved permit application to be furnished to the Boiler Division with the reports the National Board Inspection Code calls for once a welded repair needing the R symbol is complete. The welding procedures were filed before the work under R 339.5216. Paul Industries also gives the owner the weld map, examination results and test records for the boiler file.

What should a Michigan facility send to get a boiler repair priced?

Send photos of the nameplate and the posted inspection certificate, the boiler’s National Board or state number, the latest inspection report and any recommendations, the fault or alarm history, fuel type and burner model, and the outage window. For welded repairs, earlier repair reports help. Paul Industries uses that package to quote the repair and plan permits and testing.

Have a Michigan boiler that tripped or failed an inspection?

Send the nameplate, the inspection certificate and report, the fault history and your outage window. Call 201-450-8280 or request a quote.