Paul Industries provides chiller repair in Maine for hospitals, research and diagnostics labs, universities, breweries, food plants and data rooms, diagnosing and repairing centrifugal, screw, scroll and glycol chillers from York County to Aroostook County. A Maine chiller lives two lives each year: a short, warm cooling season and a long winter in which it either sits drained or keeps running against cold condenser water. Paul Industries repairs, overhauls, retrofits and replaces these machines, and handles the refrigerant records that Maine law and the 2026 EPA rule now expect.

Request a quote or call 201-450-8280

Headquarters 256 Shore Drive, Kilmarnock, Virginia
Cooling season July normal high of 80 F in Portland, Bangor and Augusta (NOAA, 1991-2020)
Maine HFC law Listed HFCs barred in new centrifugal and positive displacement chillers since January 1, 2024
Federal leak rule HFC appliances of 15 lb or more, from January 1, 2026 (EPA)
Industrial power 14.88 cents/kWh in Maine against 8.51 nationally (EIA, 2025)
Reviewed November 2026

What does chiller repair in Maine cover?

Chiller repair in Maine covers fault diagnosis, leak search and repair, compressor and motor work, tube cleaning and eddy current testing, starter and control repair, freeze damage repair and the seasonal startup and layup work that a northern climate adds to every machine. The faults themselves are the same as anywhere, and the chiller repair page sets them out with their symptoms. What changes in Maine is the calendar: when a machine can be opened, how it is protected for the months it is idle, and how a building that cools all year carries its load through January.

Maine buildings also hold an unusual mix of chiller types. Hospitals and university plants run large water-cooled centrifugal machines, labs and diagnostics plants run screw and scroll chillers with tight setpoints, and breweries, seafood plants and food processors run glycol chillers that sit outdoors or on a roof. Each type fails in its own way in this climate, and the repair plan starts from that.

How a Maine year works on a chiller

A Maine year works on a chiller through a short cooling season with moderate peaks followed by five or more months of freezing weather. NOAA’s 1991 to 2020 normals put the July high at 80 degrees Fahrenheit in Portland, Bangor and Augusta, with July lows near 60, while the January low is 16 degrees in Portland, 12 in Augusta and 9 in Bangor. The cooling season is real but brief, and the machine spends more of the year exposed to cold than to heat.

Moderate summers mean fewer compressor hours than a southern machine logs, so wear builds more slowly, but winter adds risks a southern owner seldom sees. Water left in an evaporator, condenser or outdoor run freezes and splits tubes. A chiller restarted in April after months of standing still meets condenser water colder than its controls expect. Air-cooled machines on roofs collect ice and snow on coils and fans. Most Maine chiller failures the season brings trace back to one of those three conditions rather than to summer overload.

The Maine chiller calendar and the repair work that fits each part of it
PeriodChiller conditionRepair and service that fitsRisk to plan for
November to MarchComfort machines drained or idle; year-round loads on free cooling or low-load operationOverhauls, compressor rebuilds, tube cleaning, eddy current testing, starter and control upgradesFreeze damage to any vessel or line holding water; low head pressure on running machines
April and MayStartup ahead of the first warm spellRefill, leak check, safeties test, oil analysis, startup under loadCold condenser water at startup; leaks that opened over winter
June to AugustPeak load; tourism and summer production on the coastDiagnostics, leak repair, control tuning, quick component swapsLittle spare capacity; outages kept short and planned around the load
September and OctoberLoad falls; harvest and processing season inlandLayup, drain-down, glycol testing, coil cleaning, condition reports for winter workMissed drain points and low glycol strength before the first freeze

How does a Maine winter damage a chiller that sits idle?

A Maine winter damages an idle chiller mainly through freezing: water trapped in evaporator and condenser tubes, water boxes, pump casings or outdoor piping expands as it freezes and cracks tubes and fittings. On a water-cooled machine, a cracked evaporator tube lets water into the refrigerant circuit when the system is refilled, which contaminates the oil and refrigerant and turns a tube repair into a full dehydration and cleanup.

Protection comes from a written layup procedure: drain the evaporator, condenser and any outdoor lines completely, open vents so no water is held by vacuum, blow out low spots with air, and leave water boxes open or filled with a properly mixed glycol solution. Crankcase and oil heaters normally stay energized. Paul Industries writes layup and restart procedures for each machine it maintains and checks the drain points against the piping drawings, because the low point that holds water is often in a line nobody looks at, such as a condenser bypass or a tower makeup run.

Air-cooled chillers bring their own winter repairs. Snow drifting into coil sections and ice on fan blades unbalance the fans and bend fins, and roof units in coastal towns pick up salt spray along with snow. Spring service on these machines starts with the coil, the fan assemblies and the electrical enclosures, all of which Paul Industries inspects before the chiller is asked to run.

Chillers that run all year in Maine

Chillers that run all year in Maine serve hospitals, research labs, diagnostics clean areas, data rooms and process loads that never stop, and a Maine winter asks these machines to work in conditions a cooling-season chiller never sees. Condenser water from a tower in January comes back far colder than the design point, and without head pressure control the machine runs with too little pressure difference to feed refrigerant and return oil.

The repairs that follow are specific: tower bypass valves that stick, variable-speed fan drives that fail to slow down, condenser water pumps without proper control, oil return problems, and low refrigerant pressure trips at light load. Many year-round plants in Maine pair the chillers with a waterside economizer, a plate heat exchanger that lets the tower cool the chilled water directly when outdoor wet bulb temperatures are low. Paul Industries repairs and adjusts the changeover controls between chiller and economizer, which is where many winter faults begin.

Which Maine buildings depend most on their chillers?

The Maine buildings that depend most on their chillers are hospitals, research and diagnostics facilities, university central plants, food and beverage plants and data rooms, because their loads continue through the night and, for many, through the winter. Maine Medical Center in Portland is the state’s largest hospital by bed count, with Eastern Maine Medical Center in Bangor and Central Maine Medical Center in Lewiston behind it in Mainebiz rankings. IDEXX is headquartered in Westbrook with manufacturing there and in Scarborough, and the Jackson Laboratory has been in Bar Harbor since 1929.

Maine building types and how chiller repairs are planned in each
Building typeWhere in MaineLoad patternHow the repair is planned
HospitalsPortland, Bangor, Lewiston, Augusta, BiddefordYear-round for surgery, imaging and pharmacy; summer comfort peakRedundancy confirmed first; temporary cooling for critical rooms when one machine is the whole plant
Research and diagnosticsWestbrook, Scarborough, South Portland, Bar HarborTight temperature and humidity limits; process cooling for equipmentChange records for controlled areas; repairs between production runs
Universities and collegesOrono, Brunswick, Lewiston, Waterville, PortlandCentral plants with summer sessions and research buildingsOverhauls between semesters and in the cold months
Breweries and food plantsGreater Portland, the midcoast, Aroostook CountyGlycol loads tied to fermentation and productionRepairs between brews or runs; glycol strength and inhibitor checked together
Data rooms and telecomGreater Portland, Augusta, BangorConstant load, often with free cooling in winterOne machine at a time under a written procedure
Offices, schools and public buildingsStatewideDaytime summer peak, idle in winterDrained for winter; overhaul in the off season

Commercial chiller repair in Maine hospitals, campuses and offices

Commercial chiller repair in Maine hospitals, campuses and offices is planned around a short window of real demand, which gives these owners a choice that buildings farther south rarely have: nearly every major repair fits into the months when the chiller is idle. The work that cannot wait, such as a failed starter or a leak found in July, is diagnosed and repaired with the building’s remaining capacity checked first, and anything larger is staged for autumn.

Industrial chiller repair service for Maine plants

An industrial chiller repair service for Maine plants follows production rather than weather. Diagnostics manufacturers cool equipment and controlled rooms all year, food processors cool product and process water through harvest and fishing seasons, and machine shops and composites makers cool spindles, molds and presses. Paul Industries plans these repairs into scheduled shutdowns and, where a process cannot stop, brings in temporary cooling and ties it into the process loop before the machine is opened.

Glycol chiller repair at Maine breweries and food plants

Glycol chiller repair at Maine breweries and food plants usually starts with the fluid. Propylene glycol that has been diluted by years of top-up water loses freeze protection, and inhibitor that has broken down lets the loop corrode from the inside. Outdoor and rooftop glycol chillers in Maine see the full winter, so a weak mix is a freeze risk in the chiller’s own evaporator. Paul Industries tests concentration and inhibitor at each visit, repairs pumps, valves and controls on the glycol skid, and links cellar loop work to the glycol cooling systems that serve fermenters and bright tanks.

Refrigerant rules for Maine chiller owners: state and federal

Refrigerant rules for Maine chiller owners come from two levels: Maine’s own hydrofluorocarbon law, 38 M.R.S. section 1613, implemented by Maine DEP rule Chapter 147, and the federal AIM Act programs that EPA runs under 40 CFR Part 84. Maine acted first on new equipment, and the federal leak repair rule now governs how existing machines are serviced.

Under the Maine statute, listed hydrofluorocarbons have been prohibited since January 1, 2024 in new centrifugal chillers and new positive displacement chillers; for centrifugal machines the list includes HFC-134a, HFC-245fa, R-404A and R-410A. Equipment acquired before that date is exempt, and equipment manufactured before it may still be installed and used. The law also forbids intentionally venting a prohibited substance while a chiller is maintained, serviced, repaired or disposed of, with an exception for small releases during a good faith recovery. DEP may grant waivers of up to two years.

Federally, EPA’s Emissions Reduction and Reclamation rule applies from January 1, 2026 to appliances holding 15 pounds or more of HFC refrigerant. The leak rate is calculated each time refrigerant is added, and leaks above 10 percent a year on comfort cooling, 20 percent on commercial refrigeration or 30 percent on industrial process refrigeration must be repaired within 30 days, or 120 days when an industrial process shutdown is needed, with initial and follow-up verification tests. Section 608 of the Clean Air Act requires certification of technicians who open these refrigerant circuits.

Refrigerants in Maine chillers and what state and federal rules mean for repair
RefrigerantTypical Maine machinesRule that governs itWhat it means for a repair
R-22Older screw and reciprocating chillers in schools, offices and plantsProduction and import ended January 1, 2020; reclaimed refrigerant still services existing systemsRepair for a short horizon; budget the replacement before the next major failure
R-123Low-pressure centrifugal machines in older central plantsHCFC phaseout completes in 2030; reclaimed and previously produced R-123 services existing machinesPurge and leak tightness protect the charge; plan the retrofit or replacement path now
R-134aCentrifugal and screw chillers from the last three decadesBarred in new centrifugal chillers in Maine since 2024; existing machines keep running; federal leak rule at 15 lb or moreRepairable and serviceable; leak records required; replacement uses a different refrigerant
R-410AScroll and small air-cooled chillers, glycol unitsOn Maine’s centrifugal list; federal GWP limit of 700 for new comfort chillers since 2025Repairable; a new machine of the same type uses a lower-GWP refrigerant
Lower-GWP refrigerantsChillers installed in Maine since the 2024 and 2025 limitsMeet state and federal limits for new equipmentRepair to the manufacturer’s procedures and the refrigerant’s ASHRAE 34 safety class

Do Maine pressure vessel rules reach a chiller?

Maine pressure vessel rules can reach a chiller, because 32 M.R.S. Chapter 131 requires every nonexempt pressure vessel to be registered and inspected, and the state’s own risk management bulletin lists refrigerant receivers and heat exchangers among the typical vessels that may require inspection, with certificates renewed every three years. The exemptions in section 15102 cover, among others, vessels operating at 15 psi or less and small vessels within set volume and pressure limits, so whether a given shell or receiver is in the program depends on its size and rating.

For a repair, the practical point is the pressure boundary. A tube bundle replacement, a nozzle repair or a weld on a shell built to ASME Section VIII is a repair to a pressure vessel, documented under the National Board Inspection Code with the inspector consulted where the vessel is registered. Paul Industries reads the nameplate and data report before a repair touches the shell, and when the work involves the plant’s boilers or absorption machines, coordinates it with the boiler repair in Maine scope.

Repair or replace at Maine electricity prices

Maine’s electricity prices make the repair or replace question sharper than it is in most states: EIA puts the 2025 average industrial price at 14.88 cents per kilowatt-hour in Maine against 8.51 nationally, and commercial customers paid 20.86 cents. Every tenth of a kilowatt per ton that a new machine saves is worth nearly twice what it would be at the national industrial average.

The season length cuts the other way for comfort-only plants. As an illustration, a 300-ton machine that a replacement would improve by 0.15 kilowatt per ton saves 45 kilowatts at full load. Over 1,200 equivalent full-load hours, which suits a Maine office or school, that is 54,000 kilowatt-hours, about $8,035 a year at the 2025 industrial rate. The same improvement on a lab or data room running 6,000 equivalent hours is 270,000 kilowatt-hours, about $40,176. Paul Industries runs this arithmetic with the owner’s own tonnage, run hours and tariff before recommending repair or replacement.

Efficiency Maine’s Custom Program funds electric efficiency projects for businesses and institutions, including chiller projects, and most of its commercial and industrial incentives require preapproval before equipment is bought. Owners weighing a replacement put that step ahead of any purchase order, and Paul Industries supplies the equipment data and savings estimate the application needs.

Centrifugal chiller repair, screw and scroll work

Centrifugal chiller repair in Maine central plants centers on bearings, impellers and seals, the purge on low-pressure machines, oil system faults, vane and variable-speed control, and the motor and starter. Low-pressure R-123 machines draw air and moisture in through leaks during idle months, so a spring purge that runs constantly is a leak report, not a nuisance. Paul Industries tracks purge run time and pump-out records as part of leak repair.

Screw chillers bring rotor and bearing wear, slide valve or capacity control faults and oil separator problems. Scroll chillers fail one compressor at a time, which keeps the machine partly running but hides the loss of capacity until the first hot week. On both, Paul Industries checks oil quality, superheat and subcooling, and the electrical condition of each compressor before a replacement is ordered.

Air cooled chiller repair and water cooled chiller repair

Air cooled chiller repair in Maine tends to center on coils, fans, controls and refrigerant leaks at vibration points, with winter damage and salt exposure on the coast adding to normal wear. Water cooled chiller repair adds the condenser side: fouled or scaled tubes, tower water treatment, condenser pumps and the head pressure control that keeps a machine stable in cold weather. On water-cooled plants, Paul Industries brushes tubes, runs eddy current tests and repairs the towers through cooling tower repair in the same outage.

How to maintain a chiller system through a Maine year

How to maintain a chiller system through a Maine year comes down to four visits built around the seasons: a spring startup, a midsummer check, an autumn layup and a winter overhaul or inspection, with daily logs kept by the operators between them. Chiller maintenance procedures for a machine that runs all year replace the layup with a winter check of head pressure control, economizer changeover and freeze protection on the tower.

The spring visit refills and vents the machine, checks refrigerant charge and leak records, tests safeties and starts the chiller under load. The summer visit reviews logs, approach temperatures and oil condition. The autumn visit drains or protects every water-holding part, tests glycol and records the machine’s condition for winter work. The winter visit covers tube cleaning, eddy current testing, compressor inspection and control upgrades while the building does not need cooling. Paul Industries offers these visits under service contracts that cover the towers, pumps and water treatment as well.

Who repairs chillers in Maine?

Paul Industries repairs chillers in Maine, from Portland and South Portland to Lewiston-Auburn, Augusta, Waterville, Bangor, the midcoast, Downeast and Aroostook County. Paul Industries, an East Coast contractor with its headquarters at 256 Shore Drive in Kilmarnock, Virginia, earlier had its base in northern New Jersey and later in Pennsylvania, and today it takes chiller work across Maine, in all 50 states and at plants outside the United States. For a chiller repair service, owners get one contract covering diagnosis, parts, refrigerant handling, repair, startup and the records.

The same company handles what comes after a repair. Paul Industries supplies and installs replacement chillers, pumps, towers and piping, supplies equipment alone where the owner’s design is already set, and carries design-build work on plant upgrades. Owners with chillers in other New England states can keep one contractor through the New England page, and a comparison with the chiller repair in Massachusetts page shows how the work differs where state inspection and building emissions rules are stricter. The headquarters state has its own guide, chiller repair in Virginia.

What does chiller repair cost in Maine?

Chiller repair cost in Maine is set by the fault, the machine type and size, the refrigerant and how much of it must be recovered or replaced, parts lead time, and whether the repair falls in the idle season or during peak load. A failed sensor or contactor is a short visit; a compressor rebuild, a retube or a cleanup after a freeze-split tube is a planned project with parts, refrigerant, testing and documentation.

Two Maine factors move the number. Repairs scheduled for the cold months avoid temporary cooling rental and premium scheduling, which is why many owners wait for autumn when the fault allows it. And refrigerant cost is rising as federal phasedown caps tighten, so leak repair pays back faster each year. Paul Industries prices repairs with labor, parts and refrigerant shown separately and gives a budget range first, then a firm price once the diagnosis is complete.

Chiller repair and replacement from Paul Industries across Maine

Paul Industries diagnoses, repairs, overhauls, retrofits and replaces centrifugal, screw, scroll and glycol chillers in Maine, with refrigerant records kept to the state law and the 2026 federal rule, freeze-safe layup and restart procedures, and repair or replace analysis at Maine power prices. Related Maine pages cover data center cooling systems in Maine, process piping in Maine and ultrapure water systems in Maine, and the Maine hub links the rest. Send the chiller details and the fault history to request a quote.

Standards referenced: Maine hydrofluorocarbon law, 38 M.R.S. sec. 1613 · Maine DEP rule 06-096 CMR Chapter 147 · Maine boilers and pressure vessels law, 32 M.R.S. Chapter 131 · Maine Uniform Building and Energy Code (2021 International Mechanical Code) · EPA AIM Act HFC rules, 40 CFR Part 84 · EPA Emissions Reduction and Reclamation rule, 40 CFR 84.106 · EPA Technology Transitions rule · Clean Air Act Section 608 · ASHRAE 15 · ASME Boiler and Pressure Vessel Code, Section VIII · National Board Inspection Code

Frequently asked questions

Who handles chiller repair in Portland, South Portland and Westbrook?

Paul Industries repairs chillers across Greater Portland, including hospital and campus central plants, diagnostics and laboratory buildings in Westbrook, Scarborough and South Portland, office buildings and breweries. Work in this area often involves machines that run all year for labs and controlled rooms, so repairs are planned around redundancy and the waterside economizer as well as the summer peak. Paul Industries plans each repair with the facility team before the machine is isolated.

Does Paul Industries provide chiller repair in Bangor and the Penobscot region?

Yes. Paul Industries takes chiller repair in Bangor, Brewer, Orono and the surrounding Penobscot region, where hospitals, the university campus and plants run centrifugal, screw and air-cooled machines. Bangor’s January normal low is 9 degrees Fahrenheit, so freeze protection, layup and spring restart are a large part of the work, along with the repairs a cooling season brings.

Who repairs chillers in Lewiston, Auburn, Augusta and Waterville?

Paul Industries repairs chillers in Lewiston-Auburn, Augusta and Waterville for hospitals, colleges, state and municipal buildings, mills and manufacturers. Many of these plants cool only in summer, which lets most major repairs move into the idle months, while hospital and process machines that run all year are repaired one at a time with the remaining capacity checked first.

Does Paul Industries repair chillers in Brunswick, Bath and the midcoast?

Yes. Paul Industries repairs chillers in Brunswick, Bath, Rockland and the rest of the midcoast for colleges, hospitals, manufacturers and shipyard suppliers. Coastal air carries salt, so air-cooled coils, fan assemblies and electrical enclosures get extra inspection, and coil cleaning or recoating is planned before corrosion opens a refrigerant leak.

Who services chillers in Bar Harbor, Ellsworth and Downeast Maine?

Paul Industries services chillers in Bar Harbor, Ellsworth and Downeast Maine for research facilities, hospitals, seafood processors and seasonal buildings. Research and laboratory loads run all year, while seafood and summer facilities run hard for part of the year and sit idle the rest, so service plans combine year-round maintenance with careful layup and restart.

Who installs chillers in Maine when a repair is no longer worth it?

Paul Industries installs replacement chillers in Maine, with the refrigerant chosen to meet the state law and the federal limits for new equipment, the piping, pumps and controls modified to suit, and the old machine’s refrigerant recovered. Installation is scheduled for the cold months wherever the building allows, and Paul Industries also supplies the chiller alone for owners whose design is already set.

Can a Maine building still repair a chiller that runs on R-134a?

Yes. Maine’s 2024 prohibitions apply to new chillers, and equipment acquired before the prohibition date is exempt, so an existing R-134a machine can be repaired, recharged and kept in service. The federal leak repair rule applies if the charge is 15 pounds or more, which most chillers exceed, so leak rate calculations and repair deadlines go with every refrigerant addition.

What does Maine's hydrofluorocarbon law mean for a chiller being replaced in 2026?

A new centrifugal or positive displacement chiller installed in Maine has to avoid the refrigerants listed for that equipment in 38 M.R.S. section 1613, which for centrifugal machines include HFC-134a, R-404A and R-410A. Equipment manufactured before January 1, 2024 is still allowed, and DEP can grant waivers of up to two years. The federal Technology Transitions limit of GWP 700 for new comfort chillers applies as well.

What records does a Maine chiller owner keep under the 2026 EPA leak rule?

For a chiller holding 15 pounds or more of HFC refrigerant, the owner keeps a record of each refrigerant addition with the calculated leak rate, the date and nature of any leak repair, and the initial and follow-up verification tests. Paul Industries enters these with each service visit and hands the owner a running log, so the leak history is ready for an EPA or state inquiry and for the next repair decision.

How long can a leaking chiller run before the repair is due?

Once the calculated leak rate exceeds the threshold for its type, 10 percent a year for comfort cooling, the federal rule gives 30 days to repair the leak, or 120 days when an industrial process shutdown is needed to make the repair. Verification tests follow. Paul Industries locates leaks with electronic detection, pressure and ultrasonic methods and plans the repair inside that window.

Should a Maine comfort chiller be drained every winter?

Most Maine comfort chillers that stop for the winter should be drained or filled with a correct glycol mix, along with any outdoor piping and tower lines, because one frozen tube can let water into the refrigerant circuit. Machines in heated mechanical rooms are at lower risk but still have exposed lines. Paul Industries checks each machine’s drain points against the drawings when it writes the layup procedure.

Why does a Maine chiller run in January?

Hospitals, labs, data rooms, imaging suites and process loads produce heat all year, and Maine’s cold weather removes it from the building only where the air or water side is designed to use it. Many of these plants run chillers at low load in winter or switch to a waterside economizer. Paul Industries repairs the head pressure controls, tower bypasses and changeover sequences that keep these machines stable in cold condenser water.

What does chiller maintenance cost per ton in Maine?

Cost per ton depends on the number and size of machines, whether towers, pumps and water treatment are included, the refrigerant, and how many visits the season requires. A single small air-cooled unit costs more per ton to maintain than one large centrifugal machine. Paul Industries prices a Maine service program from the equipment list and the visit schedule, showing each visit and its tasks so the per-ton figure is clear.

How do chiller maintenance contractors in Maine differ, and what should a buyer compare?

Compare what the contract covers: chillers alone or the towers, pumps, water treatment and controls with them; seasonal layup and startup; leak records under the 2026 rule; eddy current testing; and whether repairs and replacements sit under the same contract. Paul Industries covers all of these for Maine plants under one agreement, with one set of records for the machine’s life.

Can a chiller repair company in Maine help with Efficiency Maine incentives?

Yes. Efficiency Maine’s Custom Program funds electric efficiency projects for businesses and institutions, and most of its commercial and industrial incentives need preapproval before the equipment is bought. Paul Industries prepares the equipment data, the existing and proposed efficiency and the savings estimate for the application, then schedules the installation once approval is in place.

What does chiller repair and maintenance involve for a Maine brewery?

Brewery glycol chillers need correct propylene glycol strength and inhibitor, clean condenser coils, working pumps and controls, and leak-free refrigerant circuits. Outdoor units face Maine winters, so the mix must protect the evaporator as well as the cellar. Paul Industries tests the glycol, repairs the chiller and skid, and extends or rebalances the cellar loop when tanks are added.

Is a cracked evaporator tube after a freeze repairable?

Usually. The damaged tubes are located, plugged or replaced, and the refrigerant circuit is checked for water. If water entered the circuit, the refrigerant is recovered, the oil changed, the circuit evacuated and dehydrated, filter driers replaced and the charge restored before restart. Paul Industries also traces why the tube froze so the same drain point or control fault does not cause a second failure.

What should a Maine facility send to get chiller repair priced?

Send the chiller make, model and serial number, refrigerant type and charge, the alarm and fault history, recent operating logs, the last service report and the refrigerant addition records. Say whether the machine runs all year or seasonally, and whether the building has spare capacity. Paul Industries uses this to plan the diagnostic visit and then prices the repair in parts, refrigerant and labor.

Have a chiller that needs repair somewhere in Maine?

Send the chiller make, model and serial number, the refrigerant, the fault history and whether it runs all year or only in summer. Call 201-450-8280 or request a quote.