Paul Industries designs, fabricates, installs and maintains ultrapure water systems in Alaska, building reverse osmosis, electrodeionization and polishing loops for laboratories, hospitals, power plants, data halls and industrial users that need water far cleaner than any municipal supply. Alaska feed water is cold for much of the year and varies sharply by source, from glacier-fed surface water in Anchorage to iron-bearing groundwater in Fairbanks, so each system starts with the water it will actually receive. Paul Industries offers supply-only skids, design-build systems and complete installation.

Request a quote or call 201-450-8280

Headquarters 256 Shore Drive, Kilmarnock, Virginia
Anchorage supply Eklutna Lake since the late 1980s, plus wells (USGS)
Fairbanks groundwater Iron and manganese in the alluvial aquifer (USGS)
Fairbanks January normal low Minus 17.2 F (NOAA, 1991-2020)
Electricity for pumps and EDI 19.86 cents per kWh Alaska industrial average, 2025 (EIA)
Reviewed November 2026

What are ultrapure water systems in Alaska built to supply?

Ultrapure water systems in Alaska are built to supply water stripped of nearly all dissolved ions, organics, particles and bacteria, measured by resistivity close to the theoretical maximum of 18.2 megohm-centimeters at 25 degrees Celsius, for users whose processes or instruments fail with anything less. The same equipment families serve every application: pretreatment, reverse osmosis, electrodeionization or ion exchange, polishing, ultraviolet treatment, final filtration and a recirculating distribution loop.

What changes in Alaska is the front end and the environment around it. Feed water temperature, source chemistry and seasonal change shape the pretreatment and the reverse osmosis design, and the building, power cost and freight shape how the system is laid out, protected and supported. The general technology is described on the ultrapure water systems page; this page covers the Alaska design decisions.

What is ultrapure water used for in Alaska?

Ultrapure water is used in Alaska by laboratories, hospitals, power plants, data halls and a range of industrial and research users, each with its own purity target. The table sets out the main users and the standards they typically specify.

Ultrapure and high-purity water users in Alaska and the grades they specify
UserTypical useGrade or standard commonly specified
Research and testing laboratoriesAnalytical instruments, reagent preparation, cell culture, trace metals workReagent-grade deionized water (ASTM Type 1) under ASTM D1193; Type II for general lab use
Hospital sterile processingFinal rinse of surgical instruments and devicesCritical water quality under AAMI ST108
Dialysis unitsDialysate preparationWater and dialysis fluid quality under ISO 23500
Power and heating plantsHigh-pressure boiler and heat recovery steam generator makeupDemineralized water held to the plant’s conductivity and silica limits
Data halls with liquid coolingFill and makeup water for technology cooling loopsLow-conductivity, low-particle water to the cold plate supplier’s specification
Pharmaceutical and compounding usersPurified Water for preparation and cleaningUSP Purified Water conductivity and TOC limits
Electronics and coatings workRinsing, plating and precision cleaningASTM D5127 grades where electronics specifications apply

Many Alaska users need more than one grade from the same building. A hospital may need dialysis water, sterile processing water and lab water; a power plant needs boiler makeup and lab water for its chemistry program. Paul Industries designs a shared pretreatment and reverse osmosis train where that is cleaner and cheaper than separate units, with polishing sized for each user.

How is ultra pure water made from Alaska feed water?

Ultra pure water is made by removing contaminants in stages, each protecting the next: pretreatment removes particles, iron, hardness and chlorine; reverse osmosis removes most dissolved salts, organics and microorganisms; electrodeionization or mixed-bed ion exchange removes the remaining ions; and polishing with nuclear-grade resin, ultraviolet light and fine filtration brings the water to final quality in a recirculating loop.

  1. Pretreatment. Multimedia or cartridge filtration, softening or antiscalant, iron and manganese removal where the source needs it, and activated carbon or sodium bisulfite to remove chlorine or chloramine before the membranes.
  2. Feed water tempering. On Alaska systems, a heat exchanger warms cold feed water toward the membrane design temperature, often with recovered heat.
  3. Reverse osmosis. One or two passes reject most dissolved solids, silica, organics and bacteria.
  4. Electrodeionization. Continuous ion removal with electrically regenerated resin, without regenerant chemicals.
  5. Storage. A sealed tank with a vent filter or nitrogen blanket to keep carbon dioxide and particles out.
  6. Polishing loop. Polishing resin, ultraviolet treatment for bacteria and organics, final filtration and continuous recirculation past each point of use.

Paul Industries builds the train as skids, tested before shipment, and installs the loop in the building. The order of steps is common to all sites; the sizing and the pretreatment are where Alaska sources make each design different.

Feed water and water purification: Alaska sources compared

Feed water for an Alaska ultrapure system falls into three broad groups, glacier-fed and snowmelt surface water, groundwater from alluvial aquifers, and private wells or small community systems with their own chemistry. Each brings a different problem to the pretreatment, and seasonal change matters more than in most of the country.

Reverse osmosis: Anchorage feed water

For reverse osmosis, Anchorage feed water from the public system starts largely as Eklutna Lake water, which the city has imported since the late 1980s, with wells making up the rest of the supply, according to the USGS. Surface water of this kind is usually low in hardness, which helps membranes, but glacier-fed sources can carry fine suspended material in the melt season and the treated supply carries a disinfectant residual that must be removed before the membranes. Pretreatment therefore leans on fine filtration and chlorine removal, with silt density index monitored through the year, and on blending awareness when the utility shifts between surface and well sources.

Groundwater in Fairbanks and the Interior

Groundwater in Fairbanks and the Interior asks more of the pretreatment. USGS hydrologic work in the Fairbanks area reported that ground water from the alluvial aquifer can exceed drinking water limits for iron and manganese, and that some upland wells carry high nitrate, arsenic, iron and manganese. Iron and manganese foul reverse osmosis membranes and poison ion exchange resin, so Interior systems commonly add oxidation and filtration for iron and manganese ahead of the membranes, and test each well before design rather than assuming its chemistry.

Coastal and community supplies

Coastal communities and small systems in Southeast, Kodiak and the Kenai Peninsula draw on creeks, lakes and wells whose quality changes with rainfall and snowmelt. Organic color and turbidity rise after heavy rain, so pretreatment for these sources is sized for the worst season, with carbon and fine filtration to protect the membranes from organic fouling.

Pretreatment by Alaska feed water source
SourceTypical concernsPretreatment emphasis
Glacier-fed and snowmelt surface waterFine suspended material in the melt season, disinfectant residual, cold temperatureFine filtration, chlorine or chloramine removal, feed water warming, silt density monitoring
Alluvial groundwater in the InteriorIron, manganese, hardness, low dissolved oxygenOxidation and iron and manganese filtration, softening or antiscalant, membrane cleaning plan
Upland and private wellsVariable arsenic, nitrate, iron and manganeseFull well analysis first; oxidation ahead of the membranes; concentrate disposal checked
Coastal creeks and lakesOrganic color and turbidity after rain and snowmeltCarbon and fine filtration sized for the worst season; organic fouling allowances
SeawaterHigh salinity and biological loadSeawater reverse osmosis ahead of a brackish second pass; heavy intake screening

Cold feed water and reverse osmosis output

Cold feed water is the Alaska condition that most changes reverse osmosis design, because water passes through a membrane more slowly as it cools, so a membrane array that delivers its rated output at 25 degrees Celsius delivers noticeably less from feed water near freezing. Membrane manufacturers’ design data apply a temperature correction referenced to 25 degrees for exactly this reason, and winter feed water in much of Alaska sits far below that reference.

There are three ways to answer it, and Paul Industries chooses among them with the owner. More membrane area produces the required flow at the coldest feed temperature, at higher first cost. Higher feed pressure recovers some output, at higher pump energy. Warming the feed water through a heat exchanger restores output with the original array, and in Alaska the heat can often come from a source already on site: boiler condensate, a data hall’s cooling loop, generator jacket water or a building heating system. Warming also makes performance steady through the year, which simplifies the electrodeionization stage and the polishing loop downstream.

Can reverse osmosis remove arsenic from Alaska well water?

Reverse osmosis can remove arsenic from well water, but how well depends on the form the arsenic takes. Arsenic in its oxidized form, arsenate, carries a charge and is rejected well by reverse osmosis membranes; the reduced form, arsenite, common in oxygen-poor groundwater, passes through membranes much more easily. Pretreatment that oxidizes arsenite to arsenate ahead of the membranes, often the same oxidation step used for iron and manganese, makes reverse osmosis far more effective.

For an ultrapure system the arsenic question is usually about protecting the downstream stages and handling the reject stream, since the polishing stages will remove what remains. Paul Industries tests the well for arsenic species, iron, manganese, hardness and silica before design, then sets the oxidation, filtration and membrane steps to suit, and plans disposal of reverse osmosis concentrate in line with the site’s discharge arrangements.

Laboratory water at Alaska research, testing and university sites

Laboratory water at Alaska research, testing and university sites covers a wide range of demands, from environmental and fisheries testing to geochemistry, public health and clinical labs, and each lab’s instruments set its purity target. Trace metals analysis and mass spectrometry need Type I water low in the elements being measured; microbiology needs water low in bacteria and endotoxin; general glassware washing and feed to bench polishers can use Type II or Type III water.

Most buildings with several labs are best served by a central reverse osmosis and storage system feeding a recirculating Type II loop, with point-of-use polishers producing Type I water at the instruments that need it. That arrangement keeps the expensive polishing small, gives every lab a reliable supply and lets maintenance happen on one central train. Paul Industries sizes the central system on the building’s daily demand profile, adds the storage needed to ride through filter changes and membrane cleaning, and routes the loop so no branch sits stagnant. Where a lab needs water during the night or over weekends, the loop keeps recirculating and the polishers are kept ready, so the first draw of the morning meets the same quality as the last draw of the day.

Freeze protection and seasonal operation

Freeze protection shapes the layout of an Alaska ultrapure system, because water treatment equipment, tanks and loops hold water that splits housings and piping if it freezes. Systems belong in heated space, with feed and drain lines protected where they cross unheated areas, and with alarms on room temperature as well as water quality.

Seasonal operation brings a second issue. An ultrapure loop that stops recirculating grows bacteria quickly, and membranes and resin left without flow or the right storage solution degrade. Facilities that run seasonally, such as some labs and field stations, need a written layup and restart procedure: membranes stored in preservative, resin kept wet, the loop drained or kept circulating with periodic sanitization, and a qualification flush on restart before the water returns to service. Paul Industries writes those procedures into the turnover package.

Loop materials, sanitization and monitoring

Loop materials for ultrapure water are chosen to avoid adding back what the treatment removed. PVDF and other high-purity plastics suit laboratory and electronics loops where metal ions must stay at trace levels, while 316L stainless steel built to ASME BPE suits pharmaceutical and hot-sanitized loops. Deionized water and stainless steel work well together when the stainless is properly passivated and the loop is designed to keep water moving; passivation in the state is covered on passivation services in Alaska, with sanitary tubing installed and orbital welded to the same records.

Sanitization keeps the loop free of biofilm: hot water for heat-tolerant loops, ozone or chemical sanitization for others, with ultraviolet treatment in continuous service. Monitoring covers resistivity, total organic carbon, particles and bacteria, with resistivity and organic carbon logged continuously and bacteria sampled on a schedule. Paul Industries sets alarm limits for each point of use and records the results in a form the owner’s quality system can use.

Monitoring and maintenance plan for an Alaska ultrapure loop
IntervalCheck or taskAlaska note
ContinuousResistivity, total organic carbon, flow, loop temperature, room temperature alarmRoom temperature alarm protects against freezing in a power or heating failure
Daily or by monitoring systemRO feed temperature, pressures, rejection and recovery; EDI current and product qualityFeed temperature trend explains seasonal output changes
Weekly to monthlyBacteria and endotoxin sampling where required; pretreatment checks for iron and chlorine breakthroughIron breakthrough matters most on Interior groundwater
Quarterly to annuallyCartridge and final filter changes, UV lamp replacement, loop sanitizationSpares held on site so changes wait on no shipment
As neededRO membrane cleaning, polishing resin replacementSeasonal source changes can shorten cleaning intervals

Makeup water for Alaska power and heating plants

Makeup water for Alaska power and heating plants is one of the larger ultrapure and demineralized water duties in the state, because combined cycle plants, steam plants and district heating systems lose water through blowdown, sampling and leaks, and every gallon replaced must meet the boiler or steam generator’s chemistry limits. High-pressure units are the most demanding: silica and sodium carried into steam deposit on superheater tubes and turbine blades, so their makeup water is treated almost to ultrapure quality.

Plant makeup systems in Alaska face the same cold feed water and source chemistry described above, plus a reliability requirement: a heating plant in an Interior winter cannot run short of makeup water. Paul Industries designs makeup trains with redundant reverse osmosis or electrodeionization trains, enough storage to ride through a cleaning or a membrane change, and instrumentation that trends conductivity, silica and sodium at the outlet. Boiler water treatment and condensate polishing are planned with the makeup system, and the boilers themselves are covered on boiler repair in Alaska.

Validation and records for regulated users

Validation and records decide whether an ultrapure system is accepted by a regulated user, such as a hospital, a dialysis unit, a compounding pharmacy or a laboratory working under a quality system. The water may meet the standard, but without documented design, installation and performance testing, the user cannot show that it does.

Paul Industries delivers the documents those users need: a design specification tied to the applicable standard, material and weld records for the loop, pressure and passivation records for stainless systems, instrument calibration certificates, installation and operational qualification protocols with results, and a performance sampling plan agreed with the owner. For pharmaceutical users, the work follows the approach described on validation and commissioning in Alaska. The same records help non-regulated users too, because they give the next technician a clear baseline.

Expanding or upgrading an existing Alaska system

Expanding or upgrading an existing Alaska ultrapure system usually starts with a survey of what is installed: the pretreatment’s condition, membrane age and performance, resin and EDI history, loop material and dead legs, and the monitoring in place. Many older systems can reach a higher grade or a larger flow by adding a second reverse osmosis pass, an EDI stage or a new polishing loop rather than starting over.

New points of use are added to a live loop with isolation, sanitization and a qualification period before they go into service, so the existing users keep their water throughout. Paul Industries plans each tie-in with the owner, schedules it for a low-demand period and samples the extended loop before it returns to full service.

Power use and operating cost

Power use weighs more on an ultrapure system’s running cost in Alaska than in most states. Reverse osmosis pumps, loop pumps, electrodeionization stacks and ultraviolet lamps all run around the clock, and the EIA puts the 2025 Alaska industrial average at 19.86 cents a kilowatt-hour, well over double the US figure of 8.51. A system drawing 30 kilowatts around the clock uses 262,800 kilowatt-hours a year, about $52,200 at the Alaska average against about $22,400 at the national average.

Design choices move that number. Variable speed drives on loop pumps, energy-efficient membranes, warming feed water with recovered heat rather than electricity, and sizing the loop for real demand rather than a generous margin all reduce it. Paul Industries prices these options with the base design so the owner can weigh first cost against the electric bill.

How much does ultra pure water cost to produce in Alaska?

How much ultra pure water costs to produce in Alaska depends on the purity grade, the volume, the feed water’s chemistry and temperature, the number of points of use, the loop material and length, monitoring requirements and validation documentation, plus freight and installation. A bench-scale laboratory unit is a small purchase; a central plant with a stainless loop serving a hospital or power plant is a major project.

Operating cost adds electricity, consumables such as filters, resin, membranes and UV lamps, sanitization and testing. Paul Industries gives a budget range for ultrapure water purification systems from comparable scope once the grade, flow, feed water analysis and site are known, then a firm price when the design is set, with operating cost estimated alongside.

Who installs ultrapure water systems in Alaska?

Paul Industries installs ultrapure water systems in Alaska, designing, fabricating, supplying, installing, starting up and maintaining pretreatment, reverse osmosis, electrodeionization, polishing and distribution loops for laboratories, hospitals, power plants, data halls and industrial users in Anchorage, Fairbanks, Juneau, the Kenai Peninsula and across the state. Based at 256 Shore Drive in Kilmarnock, Virginia, after earlier years in northern New Jersey and later Pennsylvania, Paul Industries accepts water system projects throughout Alaska and the other 49 states.

The same team covers the related work: purified and high-purity water for food and seafood plants on high purity water systems in Alaska, process piping on process piping in Alaska, and liquid cooling fill water on data center liquid cooling in Alaska. For the home-state counterpart, see ultrapure water systems in Virginia, and a semiconductor-scale comparison is on ultrapure water systems in Texas.

Ultrapure water for Alaska facilities from Paul Industries

Paul Industries designs, builds and maintains ultrapure water systems for Alaska laboratories, hospitals, plants and data halls, and supports owners with sites on the West Coast and nationwide. Send a recent feed water analysis, including iron, manganese, hardness, silica and arsenic for wells, the purity grade and standard required, flow and points of use, the room available and any recovered heat on site. Call 201-450-8280 or request a quote. The Alaska page lists other work across the state.

Standards referenced: ASTM D1193 (reagent water) · ASTM D5127 (electronics and semiconductor water) · USP Purified Water and Water for Injection monographs · AAMI ST108 (water for the processing of medical devices) · ISO 23500 (water for haemodialysis) · ASME BPE · AS 18.60.180-18.60.395 (Alaska boilers and unfired pressure vessels) · 13 AAC 50.027 plan review

Frequently asked questions

Who builds ultrapure water systems for labs and hospitals in Anchorage?

Paul Industries builds ultrapure water systems for laboratories, hospitals, clinics and dialysis units in Anchorage, Eagle River and the Mat-Su, from bench-scale polishers to central plants with recirculating loops. Anchorage’s public water starts largely as Eklutna Lake water, so pretreatment focuses on fine filtration and chlorine removal. Systems are tested as skids before shipment and installed, started and documented on site.

Does Paul Industries install water purification for Fairbanks and Interior facilities?

Paul Industries designs and installs water purification and ultrapure systems for labs, hospitals, power and heating plants and other facilities in Fairbanks, North Pole and the Interior. Groundwater there can carry iron and manganese, and some upland wells carry arsenic, so pretreatment usually includes oxidation and filtration ahead of the membranes. Every well is tested before design, and feed water warming offsets cold winter supply.

Can Paul Industries supply ultrapure water skids to Juneau and Southeast Alaska?

Paul Industries supplies and installs ultrapure water skids for Juneau, Ketchikan, Sitka and other Southeast communities, sized for barge or air delivery and tested before they ship. Surface sources in Southeast change with rainfall and snowmelt, so pretreatment is sized for high organic color and turbidity. Paul Industries offers supply-only skids, design-build systems or complete installation.

Who services reverse osmosis system skids at Alaska labs and plants?

Paul Industries services reverse osmosis and ultrapure systems at Alaska laboratories, hospitals and plants, including membrane cleaning and replacement, pretreatment media changes, EDI and resin service, UV lamp and filter changes, loop sanitization and instrument calibration. Service agreements can include sampling and records. Spare consumables are kept on site where freight times would otherwise delay a change.

Why does an RO unit produce less water in an Alaska winter?

Water passes through reverse osmosis membranes more slowly as it cools, so output falls when feed water temperature drops in winter. A system sized on summer water can fall short in January. The fixes are more membrane area, higher feed pressure, or warming the feed water with a heat exchanger, often using recovered heat. Paul Industries sizes systems on the coldest expected feed temperature.

Can recovered heat warm the feed water for an ultrapure system?

Recovered heat suits feed water warming well, because the duty is steady and the temperature needed is modest. Boiler condensate, a data hall’s cooling loop, generator jacket water or a building heating loop can all supply it through a plate heat exchanger, with a control valve holding the target temperature. Paul Industries designs the heat exchanger and controls so membranes never see water above their limit.

How do iron and manganese affect an ultrapure system on well water?

Iron and manganese oxidize and deposit on reverse osmosis membranes and foul ion exchange resin, cutting output and shortening their life. USGS work in the Fairbanks area reported both in the alluvial aquifer. Pretreatment usually oxidizes them and removes them with filtration media before the membranes, with breakthrough monitored. Paul Industries sizes that pretreatment from a full analysis of the actual well.

What does ASTM D1193 Type I water require?

ASTM D1193 Type I reagent water, often called Type 1, requires resistivity above 18 megohm-centimeters at 25 degrees Celsius along with low limits for total organic carbon, sodium, chloride and silica, and it is the grade most analytical laboratories specify for sensitive instruments. Type II and Type III are lower grades for general lab use and feed water. Paul Industries designs polishing to meet the grade at the point of use.

How do deionized water and stainless steel get along in an ultrapure loop?

Deionized water is aggressive toward many metals because it holds almost no dissolved ions, but properly passivated 316L stainless steel resists it well and is standard in pharmaceutical and hot-sanitized loops. For laboratory and electronics loops where metal ions must stay at trace levels, PVDF or other high-purity plastics are common. Paul Industries selects the material for the grade, sanitization method and temperature.

What water does a hospital sterile processing department need in Alaska?

Sterile processing departments follow AAMI ST108, which sets water quality for each stage of device processing, with critical water, typically produced by reverse osmosis and polishing, for final rinses. Alaska hospitals face the same requirements as hospitals elsewhere, with feed water and temperature differences handled in the pretreatment. Paul Industries designs, installs and maintains the treatment and distribution with the monitoring records the standard expects.

Does an ultrapure water plant need state plan review in Alaska?

Mechanical systems in new construction and alterations go through plan review under 13 AAC 50.027, either with the Division of Fire and Life Safety or with a municipality that holds a deferral, such as Anchorage, Fairbanks or Juneau. Pressure vessels such as large filter housings may also fall under the state boiler and pressure vessel law unless exempt. Paul Industries prepares the drawings and vessel records for those reviews.

How is an ultrapure loop kept clean during a facility shutdown?

The safest approach is to keep the loop recirculating through the UV and polishing stages at low flow, with periodic sanitization. Where the system must stop, membranes go into preservative, resin stays wet, the loop is drained and dried or filled with a sanitizing solution, and a restart procedure flushes and tests before use. Paul Industries writes and carries out these procedures for seasonal Alaska facilities.

Can one ultrapure system serve a lab and a dialysis unit in the same Alaska hospital?

One shared pretreatment and reverse osmosis train can feed both, with separate polishing and distribution for each user so their standards and sanitization schedules stay independent. Dialysis water follows ISO 23500 and its own monitoring, while lab water follows ASTM D1193 grades. Paul Industries designs the shared and separate parts so a fault or sanitization in one loop leaves the other running.

What happens to reverse osmosis reject water at an Alaska site?

Reverse osmosis concentrate usually goes to the sanitary sewer under the utility’s discharge rules, and some of it can be recovered for uses such as cooling tower makeup or a second-pass recovery stage. Where the source contains arsenic, the concentrate carries it, so disposal needs checking with the utility or the permit authority. Paul Industries calculates reject flow and quality during design so the discharge question is settled early.

What purity does boiler makeup water need at an Alaska power or heating plant?

High-pressure boilers and heat recovery steam generators need demineralized makeup water with very low conductivity and silica, because silica and dissolved solids deposit on tubes and turbine blades at high pressure. Lower-pressure heating boilers need softened or reverse osmosis water to far looser limits. Paul Industries designs makeup systems to the boiler or turbine supplier’s water chemistry limits and the plant’s operating pressure.

What should an Alaska facility send to scope an ultrapure water system?

Send a recent feed water analysis, including iron, manganese, hardness, silica, chlorine or chloramine, and arsenic for wells; the feed water temperature range; the purity grade and standard required; flow and points of use; available space and utilities; and any recovered heat on site. Paul Industries uses that to propose the treatment train, a budget range and an installation plan.

Planning ultrapure water at an Alaska lab, hospital or plant?

Send a feed water analysis, the purity grade and flow you need, and any recovered heat on site. Call 201-450-8280 or request a quote.