Paul Industries designs, supplies and installs data center liquid cooling in Maryland, piping coolant distribution units, cold plate row manifolds, rear door heat exchangers and the warm-water heat rejection behind them for university and federal research clusters, Baltimore colocation suites and the new hyperscale buildings in Frederick County. Maryland’s mild shoulder seasons and a summer that rarely tops 100 degrees let warm-water loops reject heat through dry coolers for most of the year, which changes what the facility water plant has to be. Headquartered at 256 Shore Drive in Kilmarnock, Virginia, Paul Industries works as an East Coast contractor on Maryland liquid cooling projects and on projects in all 50 states and overseas.

Request a quote or call 201-450-8280

Headquarters 256 Shore Drive, Kilmarnock, Virginia
Dry cooler weather BWI above 79.6 F only about 1,134 hours a year (NOAA, 2021 to 2024)
Warmest hour 102.9 F at BWI in 2024, below the W45 class supply of 113 F
Research computing NASA Goddard's Discover cluster: 213,288 cores in Greenbelt (NCCS)
Planned campus load About 2,400 MW at Quantum Frederick, Frederick County
Reviewed November 2026

Where do dense racks sit in Maryland today?

Maryland’s densest computing has grown up around federal science and research universities rather than around commercial cloud campuses, and that history shapes where liquid cooling work lands. NASA’s Goddard Space Flight Center in Greenbelt runs the Discover cluster, which the NASA Center for Climate Simulation lists at 213,288 cores and 8.28 petaflops, alongside a separate GPU cluster. Johns Hopkins houses its Rockfish cluster, more than 45,000 CPU cores plus GPU nodes, at the Maryland Advanced Research Computing Center in Baltimore. The NIH’s Biowulf cluster, which an NIH presentation put at about 100,000 cores and 900 GPUs, delivered more than a billion CPU hours to researchers in 2023.

Those systems are market facts that describe demand, and they point to the kind of room most Maryland liquid cooling projects start in: a research or enterprise space inside a building designed for other purposes, with a campus chilled water plant, limited ceiling height and a schedule set by grant cycles or federal budgets. The second pool of work is new construction on the Quantum Frederick campus, where about 2,400 megawatts of combined demand is planned on a former aluminum smelter site and new buildings can be designed for dense racks from the slab up.

What the University of Maryland data center decision says about density

The University of Maryland’s flagship cluster, Zaratan, shows how hard dense racks are to fit into older Maryland rooms. The university reports 360 liquid-cooled compute nodes and about 50,000 CPU cores, with the processors cooled directly by liquid, and the cluster is housed in DataBank’s IAD2 colocation facility in Fairfax County, Virginia, a site the university chose for its density and cooling capability. Its predecessor had relied on fans.

For Maryland owners the lesson is practical. Dense computing follows the rooms that can cool it, and a University of Maryland data center choice to colocate across the Potomac is one example of that pull. Rooms on Maryland campuses and in Maryland office parks that add a warm-water loop, CDUs and adequate floor support can keep that computing in the state, and those are exactly the projects where Paul Industries’ piping and heat rejection work applies.

How is a data center liquid cooling system laid out from rack to roof?

A data center liquid cooling system in a Maryland building has three loops that hand heat from one to the next: the technology cooling loop that runs through cold plates or rear doors, the facility water loop that carries heat away from the CDUs, and the heat rejection equipment on the roof or in the yard. The CDU sits at the boundary between the first two, with a plate heat exchanger, pumps, filters, an expansion tank and controls that hold the coolant temperature and pressure the servers need.

Older Maryland buildings shape each loop differently from a new hall. The technology loop often runs overhead because there is no raised floor; the facility loop may share risers with laboratory or office chilled water; and the heat rejection lands on a roof that was never designed for dry coolers, which brings structural review, crane lifts and sound limits at the property line into the project. New Frederick County buildings avoid most of that by placing CDU galleries and dry cooler yards in the original design. Paul Industries draws all three loops on one set of drawings so that valve tags, test points and isolation sequences match from rack to roof.

Dry cooler hours at BWI for warm-water loops

Dry cooler capacity in Maryland depends on how warm the facility water is allowed to run, because a dry cooler can only bring water down to a few degrees above the outdoor dry bulb. The table below uses NOAA’s hourly observations at Baltimore/Washington International Airport for 2021 through 2024 and assumes a 10 degree Fahrenheit dry cooler approach; it counts the hours each year when the outdoor air is too warm for a dry cooler alone to meet the supply temperature of each ASHRAE facility water class.

ASHRAE facility water classes against BWI weather (10 F dry cooler approach, NOAA 2021 to 2024 average)
ASHRAE classFacility supply limitOutdoor air limit for dry coolers aloneHours per year above that limit at BWIWhat fills the gap
W1762.6 F52.6 F5,341 (61%)Chillers most of the year; dry coolers act as an economizer in winter
W2780.6 F70.6 F2,683 (31%)Evaporative trim or chiller support from late spring to early autumn
W3289.6 F79.6 F1,134 (13%)Adiabatic spray on the dry coolers or a small trim chiller in summer
W40104 F94 F52 (0.6%)A few hours of adiabatic assist on the hottest afternoons
W45113 F103 F0 in four yearsDry coolers alone; the warmest hour recorded was 102.9 F

The jump between W27 and W32 is where Maryland plants change character. At W32, dry coolers carry the whole load for about 87 percent of the year, and the remaining summer hours can be handled with adiabatic precooling rather than a full chiller plant. At W40 and above, compressors can be left out of the rack heat path entirely. The server vendor sets the limit: cold plates on current accelerators are often specified for warm supply water, but the exact direct to chip cooling temperature allowed by each platform must be confirmed in its documentation before the plant is sized.

Which data center liquid cooling solutions fit a Maryland room?

Data center liquid cooling options in Maryland range from rear door heat exchangers that leave the servers untouched to cold plates on every processor and full immersion, and the right answer depends on rack density, the building and the hardware roadmap. Most Maryland projects mix two of them: cold plates on the dense GPU racks and rear doors or air cooling on the storage and network rows around them.

Liquid cooling methods and where each fits Maryland buildings
MethodHow heat leaves the rackTypical Maryland fitPiping and plant impact
Rear door heat exchangersWater coil on the rack door absorbs exhaust heatOlder research rooms and colocation cages that cannot change server hardwareChilled or cool water to each door; condensation control on humid days
Single phase direct to chip coolingWater-glycol coolant through cold plates, with fans for the remaining heatGPU clusters at universities and federal labs; new Frederick County hallsCDUs, row manifolds, fine filtration, warm facility water
Two phase direct to chip coolingDielectric fluid boils in the cold plate and condenses in the CDUVery dense racks where the hardware maker supports itRefrigerant-style piping and controls on the rack side; facility water on the condenser side
ImmersionServers submerged in dielectric fluid in tanksPurpose-built rooms with floor capacity and service space for tanksHeavy tanks, fluid handling, facility water to tank heat exchangers

Each of these approaches needs facility water, and each puts different demands on space and access. Immersion is covered on data center immersion cooling; for national detail on CDUs, cold plates and ASHRAE classes, see data center liquid cooling. Owners weighing a direct to chip cooling system against rear doors in a research building usually find the answer in the hardware: if the next cluster arrives with cold plates already fitted, the room needs a CDU and manifolds whatever else it has.

Retrofitting a university or federal computing room

A university or federal computing room in Maryland usually sits inside a laboratory or office building, and that building sets the boundaries of a liquid cooling retrofit before any equipment is chosen. Ceiling plenums share space with laboratory exhaust and sprinkler mains, floors may be slab-on-grade with no raised floor at all, and building management is shared with researchers who need the rest of the building running. Security screening on federal sites adds lead time for every worker and delivery.

Paul Industries starts with a survey of the room, the routes from the mechanical room and the campus chilled water connection. Overhead pipe racks with drip trays are common where there is no raised floor, and the data center liquid cooling piping is typically stainless or copper on the technology cooling loop and steel on the facility side, with isolation valves at every row so that one row can be serviced without draining the others. Hot work in occupied research buildings follows the campus permit process, and press-fit or grooved joints are often chosen where welding inside the room is impractical.

Structural review comes next. Liquid-cooled racks weigh far more than the air-cooled racks many Maryland research rooms were built for, and a CDU full of coolant adds point loads of its own. The building engineer confirms floor capacity, and Paul Industries sets equipment and supports to match.

The facility water side: tying into a campus chilled water plant

A campus chilled water plant can feed a liquid cooling retrofit, but its supply water is usually far colder than cold plates need, and running that cold water into a room on a humid Maryland day invites condensation on every pipe and fitting. Many Maryland campuses run central plants at chilled water temperatures chosen for laboratory dehumidification, which suits air handlers but wastes chiller energy on rack heat.

The usual answer is separation. The CDU’s heat exchanger isolates the technology cooling loop from the campus water, and a mixing valve or a dedicated warm-water loop raises the facility side to the temperature the cold plates actually need. Where load grows beyond what the campus plant can spare, a dedicated dry cooler loop on the roof or in a yard takes the rack heat directly, and the campus plant only trims it in summer. That arrangement suits a W32 or W40 design, where BWI weather allows dry coolers to do most of the work.

The facility loop and its heat rejection are covered in more depth on data center cooling in Maryland. Paul Industries designs the hydraulic separation, sets the control valves and balances flows so that adding a liquid-cooled row does not starve the laboratory air handlers sharing the same plant.

Direct to chip cooling using water: coolant, chemistry and filtration

Direct to chip cooling using water relies on a treated water-glycol mixture in the technology cooling loop, because the narrow channels inside cold plates clog easily and corrode when chemistry drifts. The cold plate maker specifies the coolant, its inhibitors and the filtration level, and the CDU carries the filters and strainers that hold it there.

Cleanliness during construction decides how the loop performs for years. Paul Industries keeps pipe ends capped, flushes the loop with filtered water before connecting any rack, verifies particle counts and chemistry against the hardware maker’s limits, and records the fill volume and inhibitor concentration. Glycol concentration on any loop with outdoor dry coolers is set for Maryland winters, since BWI saw an average of 624 hours a year at or below freezing from 2021 to 2024 and Western Maryland runs colder.

Reusing rack heat on Maryland campuses

Rack heat from a warm-water liquid cooling loop leaves the CDU warm enough to be useful, which gives Maryland universities and hospital campuses with heating plants an option that air-cooled rooms never offered. Return water from a W40 or W45 loop can preheat domestic hot water, warm laboratory makeup air or feed a heat pump that lifts it to campus heating temperatures, offsetting boiler fuel in the colder half of the year.

The practical limits are distance and timing. Heat is easiest to reuse in the same building or the one next door, and summer surplus still needs dry coolers. Paul Industries pipes the heat recovery exchanger, the bypass that sends surplus heat to the dry coolers, and the controls that decide which path the water takes, so the servers see the same supply temperature whichever way the heat goes.

Data center liquid cooling leak detection and drip control

Data center liquid cooling leak detection in a Maryland room combines sensing cable under manifolds and CDUs, spot sensors in drip trays, and pressure and flow monitoring in the CDU that spots a slow loss before any liquid reaches the floor. Each signal goes to the building management system and to the CDU controls, which can isolate a row automatically.

Physical protection matters as much as sensing. Drip trays under overhead piping, dry-break quick connects at the rack, and manifolds placed below or beside servers rather than above them reduce what any leak can reach. Paul Industries pressure tests every joint before coolant goes in, and tests each sensor by wetting it during startup so the owner sees the alarm path work.

Proving the loop before servers connect

A new liquid cooling loop in Maryland is proven in four steps before any server is plugged in: a pressure test of every joint, a flush to the cleanliness the cold plate maker specifies, a controlled fill with the specified coolant, and a heat load run that shows the CDUs hold supply temperature at full design load. Skipping or shortening any of them is how debris reaches cold plate channels and how weak joints show up after the hardware arrives.

Pressure testing uses the medium and test pressure set by the design and the governing piping code, held long enough to read a stable gauge, with every manifold, quick connect and hose assembly in the test boundary. Flushing runs filtered water at velocity through each branch in turn while particle counts are logged; the coolant then goes in through a filter cart, with air vented at every high point. Paul Industries records each step on test sheets signed at the time, and those sheets go into the turnover package with the coolant analysis, the valve tag list and the as-built drawings.

Load bank testing on the liquid side closes the sequence. Liquid-cooled load banks or heater skids connected at the rack positions draw design heat through the CDUs while the facility water and dry coolers respond, so the owner sees the whole chain from rack to roof perform on a warm Maryland day before production hardware is at risk.

Phasing liquid cooling into a live Maryland hall

Liquid cooling in an operating Maryland colocation suite or enterprise hall is added row by row, with valved branches and capped tees installed ahead of each phase so later rows connect without draining the loop. Tenants and users stay live throughout, and every tie-in to an existing chilled water main is planned with isolation points, a rollback step and temporary cooling where redundancy is thin.

A typical sequence starts with the facility water connection and the first CDU, adds manifolds and quick connects for one row, then flushes, fills and tests before the first server connects. Later rows repeat the pattern. Commissioning of each phase, including heat load testing with load banks on the liquid loop, is described on data center commissioning in Maryland.

What does data center liquid cooling cost in Maryland?

Data center liquid cooling cost in Maryland is set mostly by the number of racks converted, the density per rack, the distance from the facility water source and the condition of the building, rather than by the CDUs alone. A research room retrofit with long pipe runs through an occupied laboratory building costs more per rack than a new Frederick County hall designed for cold plates from the start, even when the equipment is identical.

What moves the price of a Maryland liquid cooling project
FactorLower cost caseHigher cost case
BuildingNew hall with overhead pipe racks designed inOccupied research building with crowded plenums and no raised floor
Facility waterDedicated warm-water loop with dry coolersTie-in to a campus chilled water plant with new mixing and controls
Coolant distributionRow CDUs serving full rows of identical racksIn-rack CDUs for mixed hardware and short rows
RedundancyN+1 CDU pumps on one loopSeparate A and B loops to every rack
Site accessCommercial campus with open loading docksFederal site with escorted access and screened deliveries
ScheduleWork in a vacant hall before servers arrivePhased work around live tenants and research users

Three delivery routes are available. Paul Industries can supply CDUs, manifolds, dry coolers and prefabricated pipe modules; deliver the whole system on a design-build basis from facility water to rack connection; or install to an engineer’s design. Pricing starts with a budget range drawn from comparable work and becomes a firm price once rack counts, hardware and routes are fixed.

Who installs data center liquid cooling in Maryland?

Paul Industries installs data center liquid cooling in Maryland, from CDUs and row manifolds to the facility water loop, dry coolers and controls, at research buildings in College Park, Greenbelt, Bethesda and Baltimore, colocation suites around Columbia and Laurel, and new campus buildings in Frederick County. Buyers comparing data center liquid cooling providers in Maryland get one contract covering data center liquid cooling design, piping, pressure testing, flushing, fill and startup, with the records an operator needs to run the loop.

The wider mechanical package for a hall, including generators’ fuel piping and plant support systems, is described on data center mechanical contractors in Maryland, and the welded facility piping behind a CDU draws on industrial welding services in Maryland and process piping in Maryland. Research owners can read more on research labs and universities. For the headquarters state, see data center liquid cooling in Virginia, and for dense racks in older urban buildings, data center liquid cooling in New York.

Liquid cooling from Paul Industries across Maryland

From its headquarters at 256 Shore Drive, Kilmarnock, Virginia, Paul Industries delivers liquid cooling for data halls and research rooms across Maryland, from Frederick County, Hagerstown and the I-270 corridor to Baltimore, Annapolis, Southern Maryland and the Eastern Shore. The company designs, supplies, installs, tests, starts up and maintains CDUs, cold plate loops, rear door heat exchangers, facility water piping and warm-water heat rejection, and takes the same work in all 50 states and at facilities outside the United States. Send the rack count and hardware, the facility water source and the room drawings, then call 201-450-8280 or request a quote.

Standards referenced: ASHRAE TC 9.9 Liquid Cooling Guidelines (W17 to W45 facility water classes) · ASHRAE Thermal Guidelines for Data Processing Environments · Open Compute Project cold plate and coolant guidance · ASME B31.9 · ASME B31.3 · 2021 International Mechanical Code (Maryland Building Performance Standards) · NFPA 75

Frequently asked questions

Who does liquid cooling for data centers in Baltimore and Columbia?

Paul Industries designs and installs liquid cooling for colocation suites, enterprise halls and research rooms in Baltimore, Columbia, Laurel and across Howard and Anne Arundel counties. Work in these buildings usually means tying a new technology cooling loop into an existing chilled water plant while tenants stay live, so every connection is planned with isolation valves, a rollback step and temporary cooling where redundancy is thin.

Does Paul Industries install liquid cooling for research computing in College Park, Greenbelt and Bethesda?

Yes. Paul Industries pipes CDUs, cold plate manifolds and rear door heat exchangers for university and federal research computing rooms in Prince George’s and Montgomery counties. These projects often run inside laboratory buildings with shared plenums and campus chilled water, and some involve escorted access on federal sites, which Paul Industries plans into the schedule from the start.

Can Paul Industries pipe liquid-cooled halls on Frederick County campuses?

Yes. New buildings in Frederick County can be designed for cold plate racks from the start, with overhead pipe racks, row CDUs and warm-water dry coolers sized for the full build-out. Paul Industries installs headers and valved branches for later phases with the first one, so each new block of racks connects to the loop without draining it.

Can a server room in Annapolis or Anne Arundel County move to rear door heat exchangers?

Yes, and rear doors are often the simplest first step for a room whose servers cannot change. Each door needs a supply and return from a cool water loop, controlled above the room dew point so the coil stays dry on humid Chesapeake summer days. Paul Industries runs the branch piping, sets the controls and tests each door under load.

What should Maryland buyers ask data center liquid cooling companies before signing?

Ask how the technology cooling loop will be flushed and how cleanliness will be proven before servers connect, what pressure test medium and duration will be used, how leak detection will be tested, which coolant and inhibitor the hardware maker requires, and what records the owner receives at turnover. Paul Industries answers each of those in its proposal, with the test procedures attached.

Does data center liquid cooling use water in a Maryland hall?

The technology cooling loop is closed, so it holds a fixed volume of treated water-glycol that is not consumed. Water use depends on heat rejection: dry coolers use none, while cooling towers and adiabatic sprays evaporate water on warm days. At warm supply temperatures, Maryland weather lets dry coolers carry most of the year, which keeps water use low.

What direct to chip cooling temperature suits a Maryland hall with dry coolers?

The warmest supply the server hardware allows gives the most dry cooler hours. At BWI, a W32 supply of 89.6 degrees needs help for about 1,134 hours a year with a 10 degree dry cooler approach, while a W40 supply of 104 degrees needs help for only about 52 hours. Paul Industries confirms the hardware limit before sizing the dry coolers.

When does two phase direct to chip cooling make sense for a Maryland research cluster?

A two phase system makes sense when rack densities exceed what single phase cold plates can carry comfortably and the hardware maker supports the dielectric fluid and CDU design. The rack side then behaves more like refrigeration piping, while the facility side still delivers water to the CDU condenser. Paul Industries installs both sides and tests them to the maker’s procedures.

What can Maryland owners learn from the University of Maryland data center decision for Zaratan?

The university placed its 360-node liquid-cooled cluster in a Virginia colocation hall chosen for density and cooling, which shows how quickly dense computing leaves rooms that lack a warm-water loop and floor capacity. Maryland owners who add CDUs, manifolds and heat rejection to their own rooms can host comparable systems, and Paul Industries scopes those upgrades.

What changes when a new Maryland building is planned as a direct to chip cooling data center?

Planning a building as a direct to chip cooling data center from the start puts CDU galleries, overhead pipe racks, floor capacity for heavy racks and a warm-water dry cooler yard into the base design, instead of fitting them around air-cooled layouts later. Facility water can run warm enough to drop most chiller capacity. Paul Industries builds the headers and branch valves for every future row with the first phase.

Can a campus chilled water plant feed liquid-cooled racks directly?

Campus plants usually supply water far colder than cold plates need, so feeding it straight to racks risks condensation and wastes chiller energy. A CDU heat exchanger with a mixing valve, or a separate warm-water loop with dry coolers, raises the supply to the right temperature. Paul Industries designs that separation and balances flows so laboratory air handlers on the same plant keep their water.

What does a data center liquid cooling maintenance program cover in Maryland?

Data center liquid cooling maintenance covers coolant sampling for glycol strength, inhibitor level, pH and particulates; filter and strainer changes in the CDUs; checks on pump redundancy and valve operation; leak sensor tests; and inspection of quick connects and hoses. Glycol on dry cooler loops is checked before each winter. Paul Industries offers that program under a service contract.

Which delivery routes does Paul Industries offer for Maryland liquid cooling projects?

Paul Industries supplies CDUs, manifolds, dry coolers and prefabricated pipe modules for owners who want equipment only, delivers complete systems on a design-build basis, and installs to an engineer’s design where one exists. Every route includes submittals, startup support and turnover records matched to the scope.

How is a liquid-cooled loop protected from freezing in Western Maryland?

Any loop that runs through outdoor dry coolers in Washington, Allegany or Garrett County needs glycol at a concentration tested against the coldest expected night, plus heat tracing or drain points on exposed piping that can sit stagnant. The technology loop inside the building stays warm, but its facility side does not. Paul Industries tests glycol strength at fill and records it for the operator.

Can liquid cooling be added to a Maryland colocation hall while tenants stay live?

Yes. The work proceeds row by row, with hot taps or line stops where existing mains lack valves, and each new branch is flushed, filled and pressure tested before it is opened to the loop. Paul Industries writes a method statement for every tie-in, agreed with the operator, so live tenants keep their cooling throughout.

Which factors move data center liquid cooling cost on a Maryland project?

Rack count and density, the distance and route from the facility water source, the building’s ceiling and floor conditions, CDU redundancy, site access rules and phasing around live users drive the cost far more than equipment prices. A new hall designed for cold plates costs less per rack than a retrofit in an occupied laboratory building. Paul Industries prices each driver separately.

How are liquid cooling leaks caught early in a Maryland research room?

Sensing cable under manifolds and CDUs, spot sensors in drip trays, and CDU monitoring of pressure, flow and reservoir level together catch a leak while it is small. Alarms reach the building management system and can close row isolation valves automatically. Paul Industries tests every sensor at startup by wetting it, so the owner sees each alarm reach its destination.

What information lets Paul Industries scope liquid cooling for a Maryland room?

Send the rack count, the hardware model and its coolant and temperature requirements, the planned density per rack, room and building drawings, the facility water source and its temperatures, and any access rules for the site. With those, Paul Industries prepares a budget range from comparable work and then a firm price once routes and equipment are fixed.

Bringing dense racks into a Maryland room?

Send the rack count and hardware, the facility water source and the room drawings. Call 201-450-8280 or request a quote.