Paul Industries designs, installs and services data center liquid cooling in Minnesota: coolant distribution units, direct-to-chip cold plate loops, rack manifolds, rear-door heat exchangers and the facility water loops, dry coolers and chillers behind them, for halls from the Twin Cities to Rochester, St. Cloud and Duluth. Liquid cooling suits Minnesota unusually well, because the warm facility water that dense racks accept can be cooled by outdoor air for nearly the whole year, and the heat it carries is worth something in a state with a long heating season. Paul Industries, headquartered in Kilmarnock, Virginia, builds these loops across Minnesota and in all 50 states.

Request a quote or call 201-450-8280

Headquarters 256 Shore Drive, Kilmarnock, Virginia
Winter design Energy code climate zones 6A and 7 (Minn. R. 1323.0514)
Cold nights Minneapolis lows at or below 20 F on 82 nights a year (NOAA)
Water law DNR permit conditions for large data centers name closed-loop systems
Power price Minnesota commercial average 12.35 cents/kWh in 2025 (EIA)
Reviewed November 2026

Why data center liquid cooling in Minnesota runs on outdoor air

Data center liquid cooling in Minnesota runs on outdoor air for most of the year because direct-to-chip racks accept facility water far warmer than the Minnesota air. Minneapolis averages a July high of 83°F and only about 13 days a year at 90°F or above, while a liquid-cooled rack fed from an ASHRAE W32 or W40 facility loop accepts supply water up to 32°C or 40°C, roughly 90°F to 104°F. A dry cooler only has to bring the return water a few degrees above the outdoor dry bulb to make that supply temperature, so chillers become a backup or a trim for the hottest hours.

The result is a plant with fewer compressors, little or no evaporation and a smaller electric overhead. The national guide to cold plates, CDUs, rear doors and immersion is on the data center liquid cooling page; this page covers what Minnesota changes in the design, the installation and the operation.

How does data center liquid cooling work in a Minnesota hall?

Data center liquid cooling in a Minnesota hall works as a chain of three loops. At the rack, a technology cooling system loop pumps a treated coolant, often propylene glycol and water, through cold plates bolted to the processors and accelerators. A coolant distribution unit, or CDU, moves that coolant, filters it and passes its heat across a plate heat exchanger to the facility water system. The facility loop then carries the heat to dry coolers, cooling towers or chillers outdoors.

Answering how does data center liquid cooling work in practice comes down to temperatures and separation. The rack loop runs at a supply temperature above the room’s dew point, so nothing sweats. The CDU keeps the small, clean rack loop separate from the large facility loop. And the facility loop in Minnesota runs on glycol wherever it leaves the building, because it meets air well below freezing for months.

Liquid cooling loops in a Minnesota data hall and what each needs
LoopTypical fluidMain componentsMinnesota concern
Technology cooling system (rack loop)Propylene glycol and water or treated water with inhibitorsCold plates, rack manifolds, quick disconnects, CDU secondary pumps and filtersFluid cleanliness and dew point margin as dry winter air meets a humidified hall
Facility water systemTreated water indoors, glycol outdoorsCDU heat exchangers, primary pumps, headers, valves, buffer tanksFreeze protection at the building wall, glycol strength for zone 6A or 7
Heat rejectionGlycol or tower waterDry coolers, adiabatic coolers, towers, trim chillersSnow, ice and fan control at 20 below; summer trim on the few hot days
Heat reuse branch (optional)Facility waterHeat exchangers, heat pumps, building or district hot water connectionMatching reuse demand to a heating season that runs from fall to spring

Data center liquid cooling temperature and Minnesota weather

Data center liquid cooling temperature is the first decision on a Minnesota project, because the facility water supply temperature sets how many hours the plant runs without compressors. ASHRAE TC 9.9 groups facility water into classes such as W27, W32, W40 and W45 by maximum supply temperature in degrees Celsius. A Minnesota plant designed for W32 or W40 can reject heat through dry coolers on all but a handful of summer hours, while a W17 or W27 design needs chillers for much more of the year.

The server maker’s limit and the hall’s mix of liquid and air cooling both narrow the choice. Rear-door heat exchangers and air-cooled equipment in the same hall often need cooler water than cold plates, so many Minnesota designs run two facility water temperatures from one plant: warm water for liquid-cooled racks, cooler water for coils. Paul Industries designs the plant around the warmest supply the equipment accepts and adds a cooler branch only where it is needed.

Glycol, freeze protection and data center liquid cooling coolant for Minnesota winters

Glycol strength in a Minnesota liquid cooling plant is set from the winter design point of the site’s climate zone. The 2024 Minnesota Commercial Energy Code places 23 northern counties, including St. Louis, Carlton, Lake, Cook, Itasca and Beltrami, in climate zone 7 and the rest of the state in zone 6A, and Minneapolis alone averages 22 nights a year at or below 0°F. Outdoor dry coolers, yard piping and any coil exposed to outside air carry glycol rated below the site’s design low with margin.

Inside the hall, the data center liquid cooling coolant in the rack loop is chosen to the server maker’s specification: commonly a 25 percent propylene glycol mix with corrosion inhibitors, sometimes treated water with biocide. Paul Industries keeps the two fluids apart with the CDU heat exchanger, so a glycol top-up outdoors never changes the chemistry the cold plates see. Data center liquid cooling glycol on the facility side is tested for concentration, pH and inhibitor reserve at commissioning and at every service visit.

Dry cooler liquid cooling plants in snow country

Dry cooler liquid cooling plants in Minnesota need more than glycol. Coils are mounted high enough to clear drifting snow, fans are controlled to avoid icing at low load, yard layouts leave room for plowing, and pump and valve sequences prove flow before opening valves to a cold coil after any outage. Paul Industries sets these details on the first layout, because moving a row of dry coolers after the first winter costs far more than spacing it correctly at the start.

Is data center water cooling closed loop in Minnesota?

Data center water cooling at the rack is closed loop everywhere: the technology cooling loop and the facility loop are sealed, pressurized circuits that lose almost nothing in normal operation. The question that matters in Minnesota is whether the heat rejection at the far end is closed as well. A dry cooler plant is closed from rack to atmosphere and uses no water; a cooling tower plant evaporates water to reject heat and draws makeup.

Minnesota’s 2025 data center law makes that difference count. For data centers of 100 megawatts or more whose consumptive water use would exceed 100,000,000 gallons a year, the Department of Natural Resources must make sure conservation measures are reasonably considered in the water-use permit, and the statute names closed-loop systems, recycling water before discharge and reclaimed water among them. Warm-water liquid cooling with dry coolers is one of the cleanest answers to that permit condition, which is one reason Minnesota campuses are adopting it.

Data center liquid cooling vs air cooling for Minnesota owners

Data center liquid cooling vs air cooling in Minnesota is less a contest than a split, because most halls will run both for years. Air cooling still serves network, storage and lower-density compute, and Minnesota’s cold air gives air-side and water-side economizers a long season. Liquid cooling takes over where rack densities climb past what fans and coils can move, and it lets the plant run warmer water, which in Minnesota converts directly into more hours without compressors.

Liquid cooling and air cooling compared for a Minnesota hall
FactorAir coolingDirect-to-chip liquid cooling
Rack densityPractical for lower and mid densitiesBuilt for the dense racks that fans and coils struggle to cool
Facility water temperatureCooler water for coils and fan wallsWarm water, W32 to W45 classes common
Compressor hours in MinnesotaMore hours, concentrated in summerFew hours; dry coolers carry most of the year
Winter humidityHumidification needed against dry winter airLess airflow to condition, but rack loop dew point still checked
Heat reuse valueLow-grade exhaust airWarm water suited to heat pumps and building heating
Installation inside the hallDucts, containment, CRAH or fan wall unitsCDUs, manifolds, piping above or below racks, leak detection

Data center liquid cooling CDU selection, manifolds and pumps

Data center liquid cooling CDU selection starts with the heat load per row, the approach temperature between facility water and rack coolant, and the redundancy target. In-row CDUs serve one row or a few racks; larger floor-mounted or facility CDUs serve whole halls through secondary headers. Each CDU carries its own data center liquid cooling pumps, usually in an N+1 arrangement, plus filtration, expansion, makeup and controls.

The data center liquid cooling manifold at the rack distributes coolant to each server through quick disconnects, and row headers feed the manifolds from the CDU. Paul Industries sizes headers for the full future load of the row, installs isolation valves so racks can be added without draining the loop, and balances flow so every cold plate sees its design rate. Liquid cooling for data center racks lives or dies on that balance, because an underfed processor throttles long before anything trips an alarm.

Data center liquid cooling direct to chip and other rack options

Data center liquid cooling direct to chip with single-phase cold plates is the main route in new Minnesota halls, with the data center liquid cooling cold plate bolted to each processor and a closed rack loop carrying heat to the CDU. Rear-door heat exchangers suit mixed rows and retrofits. Immersion tanks fit dedicated high-density pods. On liquid cooling vs immersion cooling, cold plates win where operators want standard racks and serviceability, and immersion wins where densities are extreme and the operator accepts tank handling; the immersion route is covered on the data center immersion cooling page.

Data center liquid cooling piping, materials and testing

Data center liquid cooling piping in the rack loop is usually stainless steel or approved polymer, chosen for cleanliness and compatibility with the coolant, while facility water headers are carbon steel, stainless steel or copper depending on size and fluid. Paul Industries fabricates and welds headers and branch piping to ASME B31.9 practice, with prefabricated spools built off site to cut time in the hall and stainless joints made by orbital welding where cleanliness matters.

Every data center liquid cooling loop is pressure tested, flushed until particle counts and filter checks meet the server maker’s limit, filled with the specified coolant, and sampled before the first rack connects. Paul Industries records test pressures, flush results, fluid analysis and valve positions in a turnover package, and the integrated tests are planned with the commissioning team described on the data center commissioning in Minnesota page.

Leak detection and response in a liquid-cooled Minnesota hall

Data center liquid cooling leak detection combines sensing cable or spot sensors under manifolds and CDUs, flow and pressure monitoring in each loop, and automatic isolation valves that close a branch when the controls see a loss. Drip trays under quick disconnects, documented valve locations and an operator response card complete the system. Paul Industries designs detection zones to match the isolation valves, so an alarm points the operator to a branch that can be closed without dropping the whole row.

Data center heat reuse in Minnesota

Data center heat reuse in Minnesota has a stronger case than in warmer states, because the heating season runs from fall to spring and liquid-cooled racks return water warm enough to feed heat pumps or low-temperature building heating directly. The state already has working examples of large-scale hot water heating networks: District Energy St. Paul was developed as one of the first hot water district energy systems in North America and serves downtown buildings through heat exchangers. A liquid-cooled hall beside offices, greenhouses, a campus or a district loop has a ready customer for its heat for much of the year.

The data center heat reuse Minnesota owners study most often feeds space heating, domestic hot water, snow melt or greenhouse loads, all of which peak when the outdoor air is coldest. Paul Industries designs reuse branches with plate heat exchangers that keep the data center loop isolated, heat pumps where the user needs higher temperatures, and controls that dump heat to dry coolers whenever the reuse load falls away, so the IT equipment never depends on the heat customer. The 2025 water law’s preference for closed loops and the state’s cold winters point the same direction: warm water, dry heat rejection and reuse wherever a user exists.

Adding liquid cooling to an operating Twin Cities hall

Adding liquid cooling to an operating hall in the Twin Cities usually means finding facility water for the CDUs without disturbing the air-cooled load already running. Options include a new warm-water branch from an existing chilled water plant through a heat exchanger, a dedicated dry cooler loop, or a CDU that rejects to the room air as a first step. Paul Industries surveys floor loading, overhead space and existing plant capacity, then installs hot taps or planned isolations, prefabricated headers and CDUs in stages so each new row starts while the rest of the hall keeps running.

Owners asking for liquid cooling Minneapolis colocation suites, liquid cooling Rochester MN research computing or a new hall in the south metro all start from the same survey. Where a broader central plant change is needed, the data center cooling in Minnesota page covers the plant, and the data center mechanical contractor in Minnesota page covers whole-campus builds.

What data centers use liquid cooling in Minnesota?

The data centers that use liquid cooling in Minnesota are the halls hosting dense accelerator and high-performance computing racks: hyperscale and colocation campuses being built for artificial intelligence training and inference, university and hospital research computing rooms, and enterprise halls adding a few high-density rows. Many keep a chilled water plant for air-cooled equipment and add a warm-water branch for liquid-cooled racks, so data center liquid cooling Minnesota projects often begin as a retrofit before they become the standard for new floors.

Data center liquid cooling maintenance after turnover

Data center liquid cooling maintenance covers the coolant, the filters, the pumps and the controls. Coolant is sampled for concentration, pH, inhibitor level, conductivity and bacteria; strainers and CDU filters are checked and changed on pressure drop; pump seals, bearings and vibration are trended; and isolation valves, leak sensors and alarm paths are exercised. On how often does liquid cooling need maintenance, most operators sample fluid quarterly in the first year, then set the interval from the trend, with visual checks of manifolds and quick disconnects at every rack change. Outdoor glycol strength is checked each fall before the first hard freeze.

A liquid cooling maintenance calendar for a Minnesota data hall
TaskIntervalWhy it matters in Minnesota
Rack loop fluid sample: pH, conductivity, inhibitor, bacteriaQuarterly in year one, then by trendCatches inhibitor loss and growth before cold plates foul
CDU strainer and filter checkBy pressure drop, at least each quarterParticles from new piping settle out in the first months
Outdoor glycol concentration and inhibitor reserveEvery fall, before the first hard freezeDiluted glycol splits coils and headers on a zone 7 night
Dry cooler coil, fan and snow clearance inspectionFall and late winterDrifts and ice cut airflow and trip fans at low load
Pump vibration, seals and bearingsQuarterly trendN+1 pumps only protect the load when the standby pump is sound
Leak sensors, isolation valves and alarm pathsSemiannual functional testAn untested valve is the one that sticks during a real leak
Quick disconnects and manifold visual checkAt every rack changeDamaged couplings are the usual source of small drips

Spring brings its own check in Minnesota: after the last hard freeze, Paul Industries reviews the winter’s alarm history, confirms the trim chillers start and carry load before the first warm week, and cleans dry cooler coils of the cottonwood seed, dust and road grit that collect on them through spring. A loop that ran a whole winter on economizer may also have drifted in balance as racks were added, so flows to each row are rechecked against the design schedule and the CDU setpoints are confirmed against the server maker’s current limits, which change as new hardware generations arrive in the hall.

Paul Industries services the loops it builds and loops already in service at a site, keeping fluid records and alarm history so trends show early. A data center liquid cooling chiller kept for summer trim is serviced with the same schedule the chiller repair in Minnesota page describes.

What does data center liquid cooling cost in Minnesota?

Data center liquid cooling cost in Minnesota depends on the number of racks and their heat load, CDU type and redundancy, manifold and header lengths, the facility water temperature and heat rejection choice, glycol volume, leak detection coverage, any heat reuse branch, and whether the work goes into a new hall or an operating one. Energy is the running cost: a single megawatt of pumping, fan and compressor load left on year-round consumes 8,760,000 kilowatt-hours, close to $815,000 at the 2025 Minnesota industrial average of 9.31 cents per kilowatt-hour reported by EIA, and warm-water designs cut that overhead.

Paul Industries gives a budget range from comparable work once rack counts, densities and the plant concept are known, then a firm price after design. Data center liquid cooling solutions are offered as supply-only CDUs, manifolds and skids, as design-build packages, or as complete installation from rack manifold to dry cooler.

Who installs data center liquid cooling in Minnesota?

Paul Industries installs data center liquid cooling in Minnesota, covering CDUs, rack manifolds, headers, facility water piping, dry coolers, trim chillers, glycol systems, leak detection, heat reuse branches, testing, flushing, fill and service. The same scope in the headquarters state is described on the data center liquid cooling in Virginia page, and heat reuse in a dense urban market on the data center liquid cooling in New York page. Related Minnesota work includes process piping in Minnesota and industrial welding services in Minnesota; closed facility loops are covered on the closed loop cooling systems page, and the regional view on the Midwest page.

Paul Industries liquid cooling for Minnesota data halls

Paul Industries builds and maintains liquid cooling loops for Minnesota data halls, from a few dense rows in a Minneapolis colocation suite to campus-scale warm-water plants in the south metro and greater Minnesota. For the state overview see Minnesota. Send rack counts, densities, server cooling specifications and the existing plant layout, and request a quote.

Standards referenced: ASHRAE TC 9.9 liquid cooling guidelines (W classes) · 2020 Minnesota Mechanical and Fuel Gas Code (2018 IMC) · 2024 Minnesota Commercial Energy Code (ASHRAE 90.1-2019) · Minnesota Statutes 103G.271 (DNR water-use permits) · ASME B31.9 Building Services Piping · ASHRAE 90.4

Frequently asked questions

Who installs liquid cooling for data halls in Minneapolis, Bloomington and Eden Prairie?

Paul Industries installs CDUs, rack manifolds, headers and facility water branches for colocation and enterprise halls in Minneapolis, Bloomington, Eden Prairie, Plymouth and Maple Grove. Operating halls get prefabricated headers, hot taps or planned isolations and staged row starts so the air-cooled load keeps running. Send the rack plan and the existing plant drawings to begin.

Does Paul Industries add liquid cooling to research computing rooms in Rochester and Saint Paul?

Yes. Paul Industries adds direct-to-chip and rear-door cooling to hospital, university and corporate research computing rooms in Rochester, Saint Paul and across the Twin Cities. Many of those rooms sit on a campus chilled water plant, so the work often includes a heat exchanger and a warm-water branch that keeps the campus loop and the rack loop separate.

Who builds liquid-cooled halls in Duluth, Hermantown and northern Minnesota?

Paul Industries builds liquid cooling plants for northern Minnesota sites, where St. Louis, Carlton and Lake counties fall in energy code climate zone 7. Dry coolers carry nearly the whole year there, so the design focus shifts to glycol strength, snow clearance around coils, fan control against icing and cold-start sequences after an outage.

What facility water temperature should a new Minnesota liquid-cooled hall use?

The warmest the server maker allows. W32 and W40 designs, with supply up to 32°C or 40°C, let dry coolers carry a Minnesota plant through all but a few summer hours. Halls that also feed rear doors or air coils often run a second, cooler branch. Paul Industries sets the temperature from the equipment specifications before selecting any plant equipment.

What glycol strength does a Minnesota liquid cooling plant need outdoors?

Enough to protect the outdoor loop below the site’s winter design temperature with margin, which differs between zone 6A sites around the Twin Cities and zone 7 sites in the north. Paul Industries keeps glycol to the outdoor and facility side where possible, isolates the rack loop with the CDU heat exchanger, and tests concentration and inhibitor reserve each fall.

How much water does a dry-cooler liquid cooling plant draw in Minnesota?

A plant that rejects heat through dry coolers draws almost no water, so its draw usually stays below the point where Minnesota requires a DNR appropriation permit, which is 10,000 gallons per day or a million gallons annually. Plants using cooling towers draw makeup water, and very large data centers above 100 million gallons a year face permit conditions that name closed-loop systems.

Can server heat from a Minnesota data hall warm neighboring buildings?

Warm return water from liquid-cooled racks suits heat pumps and low-temperature heating, and Minnesota’s long heating season gives that heat a use for many months. Paul Industries designs reuse branches with heat exchangers that keep the data center loop isolated and controls that send heat to dry coolers whenever the heat user’s demand falls away.

Which coolant goes in the rack loop of a Minnesota liquid cooling system?

The coolant the server maker specifies, commonly a propylene glycol and water mix with inhibitors, or treated water with biocide. The rack loop stays separate from the outdoor glycol loop through the CDU heat exchanger. Paul Industries fills from qualified fluid, samples before the first rack connects, and keeps fluid analysis records for the operator.

How is a liquid cooling loop flushed and tested before racks connect?

Paul Industries pressure tests each section, flushes with filtered water until strainers and particle checks meet the server maker’s limit, drains and fills with the specified coolant, vents and balances flow, and samples the fluid. Results, test pressures and valve positions go into the turnover package before the first rack is connected.

How many CDUs does a Minnesota liquid-cooled row need?

The count follows the row’s heat load, the CDU capacity at the design approach temperature, and the redundancy target, typically N+1 at the CDU or pump level. Large halls may use facility CDUs feeding several rows through secondary headers instead. Paul Industries sizes headers for the full future load so CDUs can be added as racks arrive.

Where should leak sensors go in a liquid-cooled data hall?

Under CDUs, under rack manifolds and quick disconnects, along overhead or underfloor headers, and at valve clusters, with zones that match the isolation valves. Flow and pressure monitoring on each loop catches losses the sensors miss. Paul Industries maps each detection zone to the valve that closes it and gives operators a response card for every zone.

Can liquid cooling be added to a Minnesota hall that only has air-cooled CRAH units today?

Yes. Options include tapping the existing chilled water plant through a heat exchanger for a warm-water branch, adding a dedicated dry cooler loop, or starting with CDUs that reject to room air. Paul Industries surveys floor loading, overhead space and plant capacity, then phases the work so each new liquid-cooled row starts without disturbing the running load.

Is immersion cooling used in Minnesota data centers?

Immersion suits dedicated high-density pods where the operator accepts tank handling and dielectric fluid management. Most new Minnesota halls choose single-phase cold plates in standard racks, which keep serviceability familiar. Paul Industries installs both, including the facility water, heat exchangers and dry coolers that reject immersion tank heat outdoors.

Do Minnesota codes apply to liquid cooling piping inside a data hall?

Yes. Facility water piping, pumps and heat rejection equipment fall under the 2020 Minnesota Mechanical and Fuel Gas Code, and pump and fan power, controls and insulation under the 2024 Minnesota Commercial Energy Code, which adopts ASHRAE 90.1-2019. Paul Industries submits the mechanical drawings for permit and tests the installed loops against them.

How much power does a warm-water liquid cooling plant save in Minnesota?

Savings depend on how many compressor hours the warm water removes. As a reference point, one megawatt of plant load removed for a full year is 8,760,000 kilowatt-hours, close to $815,000 at the 2025 Minnesota industrial rate EIA reports. Paul Industries models the hours against the site’s weather data before the owner chooses a design.

Does Paul Industries supply CDUs and manifolds for a Minnesota project without installing them?

Yes. Paul Industries supplies CDUs, rack manifolds, prefabricated headers, pump skids, glycol fill packages and dry coolers on a supply-only basis, alongside design-build and complete installation routes. Each supply package comes with submittals, test records and startup support for the owner’s operators.

What should a Minnesota operator send to price a liquid cooling project?

Send rack counts and densities by phase, the server maker’s cooling specifications, the redundancy target, floor and overhead space, the existing plant layout and capacity, and any heat reuse ideas. With that, Paul Industries returns a budget range and a loop concept, then a firm price after design. Call 201-450-8280 or request a quote.

Bringing liquid-cooled racks into a Minnesota hall?

Send rack counts, densities, server cooling specifications and the existing plant layout. Call 201-450-8280 or request a quote.