Paul Industries designs, supplies, installs and maintains ultrapure water systems in Louisiana: pretreatment, reverse osmosis, electrodeionization, mixed-bed and polishing loops for power plants, chemical and LNG plants, laboratories and data centers from Baton Rouge and the river parishes to Lake Charles, Shreveport and New Orleans. Much of south Louisiana’s feedwater starts as Mississippi River water treated and chloraminated by a city utility, which makes pretreatment the part of a Louisiana system that most often decides whether the rest performs. Paul Industries is headquartered at 256 Shore Drive, Kilmarnock, Virginia, and builds ultrapure water systems across Louisiana and in all 50 states.

Request a quote or call 201-450-8280

Headquarters 256 Shore Drive, Kilmarnock, Virginia
Feedwater in New Orleans Mississippi River, disinfected with chloramine (SWBNO)
Nuclear units Waterford 3 at Killona and River Bend at St. Francisville (NRC)
Discharge permits LPDES, run by LDEQ since 1996 under LAC 33:IX
Pure water limit 18.2 megohm-cm resistivity at 25 C
Reviewed November 2026

What is ultrapure water used for in Louisiana?

Ultrapure water in Louisiana is used for steam generation in high-pressure boilers and nuclear and gas-fired power plants, for process and analytical work in chemical plants and laboratories, for filling and topping up the closed loops that cool dense data center racks, and for rinsing and product contact in specialized manufacturing. The common thread is that dissolved ions, silica, organics and dissolved gases in ordinary water would cause scale, corrosion, contamination or bad measurements in the equipment it feeds.

The national overview of ultrapure water technologies and specifications is on the ultrapure water systems page, and purified and compendial water for pharmaceutical and food plants is on the high-purity water systems in Louisiana page. This page covers what Louisiana adds: its feedwater, its industries, its discharge rules and its storms.

Where ultrapure water is used in Louisiana and what each user needs from it
UserWhere in LouisianaWhat the water doesParameters watched most closely
Nuclear power stationsWaterford 3 at Killona; River Bend at St. FrancisvilleReactor and steam cycle makeupConductivity, chloride, sulfate, silica, dissolved oxygen
Gas-fired and cogeneration plantsThroughout the industrial corridor and at new generation for data center campusesHigh-pressure boiler and heat recovery steam generator makeupCation conductivity, silica, sodium
Chemical plants and refineriesBaton Rouge to New Orleans corridor; Lake CharlesBoiler makeup, process water, analytical and catalyst workSilica, conductivity, total organic carbon
LNG terminalsCameron and Calcasieu parishes; Plaquemines ParishSteam and utility systems, closed cooling loopsConductivity, hardness, dissolved oxygen
Data centersNorth Louisiana campuses and city hallsFill and makeup for liquid cooling loopsConductivity, chloride, bacteria
LaboratoriesUniversities, hospitals and plant labs statewideReagent, instrument and cell culture waterResistivity, total organic carbon, bacteria, endotoxin

Ultrapure water for power plants in Louisiana

Ultrapure water for power plants in Louisiana supplies makeup to steam cycles where traces of chloride, sulfate, sodium or silica would deposit on turbine blades, corrode boiler tubes or upset reactor chemistry. Louisiana has two operating nuclear stations, Waterford 3 at Killona west of New Orleans and River Bend at St. Francisville north of Baton Rouge, both run by Entergy Operations under renewed licenses that run into the 2040s, and Louisiana Economic Development reports that Entergy’s agreement with Meta covers potential work to increase output at Waterford 3.

Gas-fired generation is growing too, including the new plants Entergy Louisiana is adding to serve data center load. Combined cycle units with heat recovery steam generators need demineralized makeup with very low cation conductivity and silica, and the polishing trains that produce it are a core part of the plant’s water system. Paul Industries designs and installs makeup trains, condensate polishers and the sampling and analyzer panels that prove water quality to the plant’s cycle chemistry program, which typically follows EPRI guidelines.

Boiler makeup in the chemical corridor and at LNG terminals

Boiler makeup in the chemical corridor is where many Louisiana plants first need ultrapure water treatment, because steam at high pressure tolerates far less silica and dissolved solids than low-pressure heating steam. More than 100 chemical plants and refineries line the river between the capital and New Orleans, drawing on it for process water as well as barge traffic, and their reactors, columns and turbines run on large steam systems.

LNG terminals in Cameron, Calcasieu and Plaquemines parishes run steam, closed cooling and utility systems that need demineralized water as well. For both, Paul Industries builds makeup trains sized for the plant’s steam demand and blowdown, with redundancy so one train can be cleaned or repaired during operation, and integrates them with the boilers and process piping they serve.

How is ultrapure water made from Louisiana feedwater?

Ultrapure water is made in stages that remove progressively smaller amounts of progressively harder contaminants: pretreatment removes particles, organics and disinfectant, reverse osmosis removes most dissolved salts and organics, electrodeionization or mixed-bed ion exchange removes the remaining ions, and a polishing loop with ultraviolet treatment, final ion exchange and ultrafiltration holds quality at the point of use. In Louisiana, pretreatment carries more of the load than in many states, because the feedwater is so often a treated surface supply.

River water and chloramine

New Orleans draws its drinking water from the Mississippi River, coagulates it with ferric sulfate, filters it through sand and anthracite, raises pH with lime and disinfects it with chloramine made from chlorine and ammonia, treating about 135 million gallons a day at its Carrollton plant for the East Bank and about 11 million at Algiers for the West Bank. That water is safe and clear, but for an ultrapure water system it brings three challenges. Chloramine attacks polyamide RO membranes and has to be removed, and it breaks down more slowly on activated carbon than free chlorine, so carbon beds are sized for longer contact or replaced with catalytic carbon or bisulfite dosing. Ammonia from the chloramine passes partly through RO and adds load to the ion exchange or EDI stage. And river-derived organics, which vary with season and flow, raise the total organic carbon the system must remove.

Plants with their own river intakes

Plants that take water directly from the river face suspended solids, color and organics that change with the river’s stage. Clarification and media filtration or ultrafiltration ahead of RO protect the membranes, and an ultrapure water filtration system designed for those swings keeps the RO from fouling every time the river rises.

Stages of an ultrapure water system on Louisiana feedwater
StageWhat it removesLouisiana design point
Clarification or ultrafiltrationSuspended solids, colloids, some organicsNeeded on direct river intakes; sized for high-river turbidity
Carbon, catalytic carbon or bisulfiteChlorine and chloramine, some organicsChloramine on city supplies requires longer contact or catalytic media
Softening or antiscalantHardness ahead of ROHardness and silica set RO recovery
Reverse osmosis, often two passMost dissolved salts, organics, silicaWarm feedwater raises salt passage; ammonia passes in part
Electrodeionization or mixed bedRemaining ions, carbon dioxide, silicaAmmonia and carbon dioxide load set EDI sizing
Polishing loopTrace ions, organics, particles, bacteriaUltraviolet for TOC and bacteria; continuous circulation in warm buildings

Specifying ultrapure water systems in Louisiana by end use

Specifying ultrapure water systems in Louisiana starts with the end use, because a power plant, a chemical lab and a data center fill station need different water, and building every system to the strictest grade wastes capital and operating cost. The specification sets the treatment train, the loop design and the monitoring, so Paul Industries agrees it in writing with the owner before sizing equipment.

Typical specification basis for Louisiana ultrapure water users
End useSpecification basisTypical treatment trainMonitoring at the point of use
Nuclear and high-pressure steam makeupPlant cycle chemistry program, commonly built on EPRI guidelinesPretreatment, two-pass RO, EDI or mixed bed, condensate polishingCation conductivity, sodium, chloride, silica, dissolved oxygen
Laboratory reagent waterASTM D1193 grade chosen by the labCentral RO and deionization, point-of-use polishersResistivity, total organic carbon, bacteria
Electronics and precision rinsingASTM D5127 or SEMI F63 gradeFull ultrapure train with ultrafiltration and degassingResistivity, total organic carbon, particles, dissolved oxygen, silica
Liquid cooling fill and makeupCold plate vendor’s coolant specificationRO and deionization with storage and dosingConductivity, chloride, inhibitor level, bacteria
Pharmaceutical product contactCompendial grade, covered on the high-purity pageRO, EDI, distillation where required, sanitized loopConductivity, total organic carbon, bacteria, endotoxin

The table is a starting point. A plant may tighten silica limits for a particular turbine, a lab may need endotoxin control for cell culture, and a data center vendor may forbid certain inhibitors. Each of those changes the treatment train, and the earlier they are known, the cheaper they are to include.

Ultrapure water vs deionized water

Ultrapure water vs deionized water is a difference of degree and of control: deionized water has had most ions removed by ion exchange, while ultrapure water is deionized and then further treated to remove organics, particles, bacteria and dissolved gases, and is monitored continuously to a resistivity approaching 18.2 megohm-centimeters at 25 degrees Celsius, the limit for pure water. So is ultrapure water deionized? Yes, deionization is one of its stages, but deionized water alone is not ultrapure.

A high purity water system for a boiler or a laboratory rinse may stop at RO and deionization; an ultrapure water polishing system adds the ultraviolet, final ion exchange, ultrafiltration and loop control that hold quality at the point of use. Paul Industries sizes each system to the quality the equipment actually needs, because ultrapure water costs more to make and keep than the water most uses require.

How pure is ultrapure water?

How pure is ultrapure water depends on the specification it is built to. ASTM D1193 defines grades of reagent water for laboratories, ASTM D5127 and SEMI F63 set guides for electronics and semiconductor use, with total organic carbon near 1 part per billion in demanding electronics grades, and power plant cycle chemistry limits set targets for cation conductivity, sodium, chloride and silica in the parts-per-billion range. Paul Industries writes the specification with the owner before the design starts.

Ultrapure water for Louisiana data centers and liquid cooling

Ultrapure water for Louisiana data centers is mostly a fill and makeup question: the closed loops that cool dense racks run best on deionized or RO water with an inhibitor package, never on straight city supply, and large campuses need a dependable source for every new hall and every loop drained for maintenance. The new campuses in north Louisiana and liquid-cooled halls in Baton Rouge, New Orleans and Shreveport all need that water.

Paul Industries builds skid-mounted RO and deionization systems with storage and distribution for data center campuses, and portable fill carts for smaller halls. The cooling side of those halls is covered on the data center liquid cooling in Louisiana page, and the plants that feed them on the data center cooling in Louisiana page.

Ultrapure water system for laboratory use in Louisiana

An ultrapure water system for laboratory use in Louisiana universities, hospitals, research institutes and plant quality labs usually combines a central RO and deionization system feeding a building loop with point-of-use polishers at each lab. A type 1 ultrapure water system at the bench delivers reagent-grade water for chromatography, mass spectrometry, molecular biology and cell culture, while the central system supplies glassware washers, autoclaves and type 2 needs. Paul Industries designs the central plant, the loop and the point-of-use connections together, so loop velocity, materials and sanitization suit the lab’s most demanding user.

Loops, materials and sanitization in a warm, humid state

Ultrapure water loops in Louisiana buildings run warm, because mechanical rooms and ceiling spaces in a humid subtropical climate are warm for much of the year, and warm water that stops moving grows bacteria. Paul Industries designs loops for continuous circulation at turbulent velocity, with no dead legs, sloped and drainable runs, and return to the storage tank through a polishing train.

Material choice follows the application: PVDF and high-purity polypropylene for electronics and laboratory loops where metal ions matter, stainless steel to ASME BPE for pharmaceutical and hot-sanitized systems, and stainless or high-purity plastic for power plant makeup depending on temperature and pressure. Sanitization is designed in from the start, with ozone, hot water or chemical options matched to the materials. Piping in plants falls under ASME B31.3, and installation of industrial pipe on commercial projects of $50,000 or more falls under Louisiana’s contractor licensing law, which lists Industrial Pipe Work and Insulation as its own subclassification.

Wastewater from ultrapure water production in Louisiana

Ultrapure water production creates wastewater: RO concentrate, ion exchange regenerant, EDI reject and filter backwash, carrying the salts, organics and treatment chemicals removed from the feedwater. In Louisiana, a discharge from a point source to a ditch, canal, bayou or river is regulated under the Louisiana Pollutant Discharge Elimination System, which LDEQ has administered in place of the federal program since August 1996 under LAC 33:IX. Discharges to a municipal sewer follow the receiving utility’s pretreatment rules instead.

Paul Industries designs the waste side with the system: neutralization of regenerant streams, metering and sampling points, recovery of RO concentrate to cooling tower makeup or other uses where chemistry allows, and recovery of good-quality reject streams back to the head of the plant. Raising RO recovery cuts both feedwater use and discharge volume, and Louisiana’s feedwater chemistry sets how far recovery can go before scaling.

Adding ultrapure water capacity inside an operating Louisiana plant

Adding ultrapure water capacity inside an operating Louisiana plant is usually done alongside the existing system rather than in place of it, so steam, process and lab users keep their water while the new train is built, tested and brought online. Skid-mounted trains prefabricated and factory tested off site shorten the time spent working inside the unit, and tie-ins to feedwater, product headers and drains are made during planned outages or through valved connections installed in advance.

Paul Industries plans the work around the plant’s permits and safe work practices, runs the new train to waste until its product meets specification, and then switches users over one at a time with the old train held in reserve. For plants on turnaround schedules, the switchover is timed to the outage so the boilers or units that depend on the water restart on the new supply. The same approach applies when a plant replaces aging ion exchange with RO and EDI to cut chemical handling.

Keeping an ultrapure water plant stable through Louisiana storms

Keeping an ultrapure water plant stable through Louisiana storms means planning for loss of power and loss of feedwater, because both arrive together. After Hurricane Ida came ashore in 2021, Lafourche and Jefferson parishes lost all power and outages spread through the River Parishes, according to the National Hurricane Center, and an ultrapure loop that stops circulating in a warm building begins to grow bacteria and lose resistivity soon after the pumps stop.

  • Loop pumps and critical instruments on standby power, so circulation continues through an outage.
  • Storage sized for the plant’s downstream needs during a feedwater interruption, with tank vent filters to keep contaminants out.
  • A written restart and sanitization procedure, with acceptance tests on resistivity, total organic carbon and bacteria before water returns to use.
  • Membranes and resins protected from freezing in north Louisiana and from stagnation everywhere if the system will be idle.

Operating and maintaining ultrapure water systems in Louisiana

Operating and maintaining ultrapure water systems in Louisiana is mostly a matter of watching the pretreatment, because changes in river-derived feedwater show up there first. Rising differential pressure across cartridge filters, a drop in RO normalized permeate flow or a rise in salt passage, and chloramine breakthrough after the carbon stage are the early signs that the next membrane cleaning, media change or carbon replacement is due.

Paul Industries trends normalized RO data rather than raw readings, because Louisiana feedwater temperature swings between winter and summer change membrane output on their own. Membranes are cleaned on trend, not on a fixed calendar; resins and EDI stacks are checked against product quality and silica breakthrough; ultraviolet lamps are replaced on run hours; and instruments are calibrated on the schedule the owner’s quality program sets. Loop sanitization frequency follows bacteria results, with more frequent sanitization in summer when mechanical spaces are warmest.

Every service visit produces a record the owner can show an auditor, an insurer or a plant chemist: what was measured, what was changed and what the water quality was before and after. Those records also feed the decision, years later, on when to replace membranes and resin beds as a set rather than piecemeal.

What sets an ultrapure water system price in Louisiana?

An ultrapure water system price in Louisiana is set by the flow rate and quality required, the feedwater and how much pretreatment it needs, redundancy, the length and material of the distribution loop, the number of points of use, sanitization method, instrumentation, the waste and discharge arrangements, and whether the system is built new or added to an operating plant. Running cost is driven by membranes and resins, chemicals and power; at Louisiana’s 2024 industrial average of 5.61 cents per kilowatt-hour (EIA), 75 kilowatts of continuous pump, RO and UV load costs about $36,858 a year, against about $53,414 at the national 8.13 cents.

Paul Industries prices from a water analysis, the required quality and flow, the point-of-use list and the site layout, giving a budget range from comparable systems and then a firm price once the design is agreed.

Who builds ultrapure water purification systems in Louisiana?

Paul Industries builds ultrapure water purification systems in Louisiana, from pretreatment through RO, EDI, polishing, storage, distribution loops, sampling and waste handling, and maintains them after startup. Routes include design-build, supply-only skids prefabricated and factory tested before shipment, and complete installation of an owner’s design, all under one contract with one set of records.

Owners comparing states can read about the headquarters state’s feedwater on the ultrapure water systems in Virginia page and about a neighboring Gulf state’s fab and river supplies on the ultrapure water systems in Texas page. For Gulf-wide industrial context, see the Gulf Coast page.

Ultrapure water treatment from Paul Industries in Louisiana

Paul Industries designs, fabricates, supplies, installs, validates and maintains ultra pure water treatment system packages for Louisiana power plants, chemical plants, LNG terminals, laboratories and data centers, along with industrial DI water systems for less demanding uses. For the state overview see Louisiana. Send a water analysis, the quality and flow required and the points of use, and request a quote.

Standards referenced: ASTM D1193 · ASTM D5127 · SEMI F63 · EPRI cycle chemistry guidelines · ASME BPE · ASME B31.3 · LAC 33:IX (LPDES)

Frequently asked questions

Who builds ultrapure water systems for plants in Baton Rouge and the river parishes?

Paul Industries builds ultrapure water systems for chemical plants, refineries and power plants in Baton Rouge, Ascension, Iberville, St. Charles and St. James parishes. Many of these sites take water from the Mississippi River or a river-supplied utility, so pretreatment for turbidity, organics and chloramine comes first, followed by RO, EDI and polishing sized for the plant’s steam and process demand.

Does Paul Industries install ultrapure water systems in New Orleans and Jefferson Parish?

Yes. Paul Industries installs ultrapure water systems for laboratories, hospitals, universities and industrial sites in New Orleans, Metairie, Kenner and across Jefferson Parish. City supply there is Mississippi River water disinfected with chloramine, so carbon beds are sized for chloramine removal or replaced with catalytic carbon or bisulfite dosing to protect the RO membranes.

Who installs ultrapure water for LNG and petrochemical sites in Lake Charles and Cameron Parish?

Paul Industries installs demineralized and ultrapure water systems for LNG terminals, petrochemical plants and power generation in Lake Charles, Sulphur, Westlake and Cameron Parish. Coastal sites also need storm-ready designs: standby power for loop pumps, protected storage and a written restart and sanitization procedure after an outage.

Can Paul Industries supply ultrapure water systems in Shreveport, Monroe and north Louisiana?

Yes. Paul Industries supplies and installs ultrapure water systems in Shreveport, Bossier City, Monroe and across north Louisiana, including fill and makeup systems for the data center campuses arriving in the region, laboratory systems for universities and hospitals, and boiler makeup for manufacturing plants. Freeze protection for membranes and resins is part of the design in the north.

What is ultrapure water used for at Louisiana power plants?

Louisiana power plants use ultrapure water as makeup for steam cycles and, at the Waterford 3 and River Bend nuclear stations, for reactor and steam system chemistry. Trace chloride, sulfate, sodium and silica would corrode tubes or deposit on turbines, so makeup trains and condensate polishers hold those ions in the parts-per-billion range under the plant’s cycle chemistry program.

How does chloramine in Louisiana city water affect an RO system?

Chloramine oxidizes polyamide RO membranes over time and is removed more slowly by activated carbon than free chlorine, so ordinary carbon beds sized for chlorine can let it through. Louisiana systems on chloraminated supply use longer carbon contact, catalytic carbon or sodium bisulfite dosing, with monitoring after the pretreatment stage. The ammonia released also adds load to downstream ion exchange or EDI.

Why does river feedwater make ultrapure treatment harder in Louisiana?

River water carries suspended solids, color and natural organics that change with the river’s stage and season, and even after city treatment some organics remain. Those organics foul RO membranes and raise total organic carbon in the product. Louisiana systems therefore lean harder on clarification, ultrafiltration and carbon ahead of RO, and on ultraviolet treatment in the polishing loop.

Who issues discharge permits for RO concentrate in Louisiana?

LDEQ issues them through the Louisiana Pollutant Discharge Elimination System, which it has run in place of the federal program since August 1996 under LAC 33:IX. A point-source discharge to waters of the state needs an LPDES permit; a discharge to a municipal sewer follows the receiving utility’s pretreatment rules. Paul Industries designs metering and sampling to suit either route.

Can RO concentrate be reused at a Louisiana plant?

Often, yes. RO concentrate can feed cooling tower makeup, scrubbers or washdown where its chemistry allows, and good-quality reject from later stages can return to the head of the system. Reuse lowers both feedwater use and discharge volume. Paul Industries checks the concentrate chemistry against each reuse to avoid scaling or corrosion downstream.

How long does an ultrapure loop take to recover after a Louisiana storm outage?

Recovery depends on how long circulation stopped, the loop’s temperature and its sanitization method. A loop kept circulating on standby power may need only a quality check; one left stagnant in a warm building usually needs sanitization, flushing and testing of resistivity, total organic carbon and bacteria before use. Paul Industries writes and tests that procedure at startup.

Which loop material suits a Louisiana laboratory or power plant?

Laboratory and electronics loops usually use PVDF or high-purity polypropylene to avoid metal ion pickup; pharmaceutical and hot-sanitized loops use stainless steel to ASME BPE; power plant makeup uses stainless or high-purity plastics depending on temperature and pressure. Paul Industries selects material with the sanitization method so the two are compatible.

Is a mixed-bed ion exchange or EDI better for a Louisiana ultrapure system?

EDI runs continuously without chemical regeneration, which suits steady flows and sites that want to avoid handling acid and caustic, but it needs well-pretreated RO product and can be loaded by ammonia and carbon dioxide from Louisiana feedwater. Mixed beds tolerate variation and polish to very high quality. Many systems use EDI followed by a polishing mixed bed, and Paul Industries sizes both from the water analysis.

Does Paul Industries maintain ultrapure water systems after startup?

Yes. Paul Industries maintains ultrapure systems under service agreements covering membrane cleaning and replacement, resin and filter changes, ultraviolet lamp replacement, instrument calibration, sanitization and the quality records the owner’s program requires. Trend reviews flag membrane fouling or resin exhaustion early, before product quality drifts.

Can an existing demineralized water system in Louisiana be upgraded to ultrapure quality?

Usually. Adding a second RO pass, EDI or mixed-bed polishing, ultraviolet treatment and a properly designed recirculating loop often lifts an existing demineralized system to ultrapure quality. The existing pretreatment has to be checked against the new duty, especially for chloramine and organics. Paul Industries surveys the system and water data before proposing changes.

What ultrapure water quality do Louisiana data center liquid loops need?

Liquid cooling loops need deionized or RO water with low conductivity and chloride, dosed with the inhibitor and biocide package the cold plate vendor approves, rather than full electronics-grade ultrapure water. Paul Industries builds fill systems that meet the vendor’s specification and records conductivity and chemistry on each fill.

What should a Louisiana site send to get an ultrapure water system designed?

Send a recent feedwater analysis, the required product quality and specification, peak and average flow, the list of points of use, the available space and utilities, and the discharge route for wastewater. Paul Industries prepares a budget range from comparable systems and a firm price once the design is agreed. Call 201-450-8280 or request a quote.

Planning ultrapure water for a Louisiana plant, lab or data center?

Send a feedwater analysis, the quality and flow you need, the points of use and the discharge route. Call 201-450-8280 or request a quote.