Paul Industries provides chiller repair in New Hampshire for hospitals, biologics and pharmaceutical plants, semiconductor and precision manufacturers, universities, data rooms, breweries and ice rinks, diagnosing and repairing centrifugal, screw, scroll and process chillers and the plants around them. New Hampshire machines live two lives: a short, moderate cooling season, and a long winter in which some sit drained while others run every day for process, lab and server loads. Paul Industries repairs, overhauls and services both kinds, and replaces, supplies and installs new chillers when repair stops paying.

Request a quote or call 201-450-8280

Headquarters 256 Shore Drive, Kilmarnock, Virginia
Cooling season Concord July normals: 83 F high, 59 F low (NWS, 1991-2020)
Winter Concord January normals: 32 F high, 13 F low
Power prices 20.11 cents/kWh commercial, 16.82 industrial (EIA, 2025)
HFC leak repair Machines holding 15 pounds or more, since January 2026 (40 CFR 84.106)
Reviewed November 2026

Where chiller repair in New Hampshire starts: the machine, the season and the load

Chiller repair in New Hampshire starts with three facts about the machine: whether it carries a year-round load or a summer-only one, what refrigerant it holds, and how it was protected through the last winter. A comfort chiller at a Concord office building, a glycol chiller at a Seacoast food plant and a process chiller serving a Nashua clean fab can show the same alarm for completely different reasons, and the diagnosis starts by placing the machine in its duty pattern.

From there the work is familiar: trending pressures and approach temperatures, finding and repairing refrigerant leaks, oil and vibration analysis, compressor and motor work, tube cleaning and eddy current testing, starter and drive repair, and control changes. The general guide to faults and repair methods is the chiller repair page. This page covers what New Hampshire adds: the climate, the buildings, the state pressure vessel law and the federal refrigerant rules as they apply to the machines found here.

How long is the chiller season in New Hampshire?

The comfort chiller season in New Hampshire is short: Concord’s July averages run from 83 degrees Fahrenheit in the afternoon to 59 at night (NWS normals, 1991 to 2020), so most office and school machines run hard for about three months and lightly in the shoulder weeks around them. The same normals put Concord’s January average low near 13 degrees, which turns every idle machine and outdoor water line into a freeze risk.

Those numbers split New Hampshire chillers into two groups. Summer-only machines collect few run hours, so their wear comes from starts, idle corrosion and freeze events rather than hours. Year-round machines at hospitals, labs, biologics plants, fabs and data rooms accumulate hours like machines farther south, but they spend the winter at light load against cold condenser water, a condition that brings its own trips and its own wear. The cool nights help: a 59 degree night lets condenser water fall, so a healthy plant has spare capacity after dark and a struggling one shows its problems in the afternoon.

Common New Hampshire chiller symptoms by season and what they usually point to
SeasonSymptomUsual causesRepair emphasis
Spring restartMachine will not start or trips within minutesFailed oil heater, low charge after a winter leak, sensors or water flow switches damaged by freezingLeak search before charging, flow proving, safety and sensor checks
Early summerHigh head pressure on the first hot afternoonsFouled condenser tubes, tower fill or fans left in poor shape, air-cooled coils blocked with debrisTube cleaning, tower repair, coil cleaning
Peak summerLeaving water temperature drifts above setpointLost capacity from fouling, low charge, worn compressor, or a load that has grownCapacity test against design, charge and compressor diagnosis
AutumnShort cycling at light loadOversized machine for shoulder loads, control settings, minimum flow issuesStaging and control changes, bypass and flow review
Winter (year-round machines)Low pressure trips, oil return problemsCondenser water too cold, head pressure control missing or failed, low evaporator flowHead pressure control, tower bypass, freeze-safe flow settings

Why is my chiller not reaching temperature?

A chiller that is not reaching temperature is either short of capacity or being asked for more than it can give, and the first job is to tell those apart by comparing the machine’s current kilowatts, approach temperatures and refrigerant pressures with its rated conditions. In New Hampshire the answer often traces back to the winter or the spring restart.

Typical causes include a refrigerant charge lost through a slow leak over the idle months, condenser tubes that scaled or fouled in the last season and were never cleaned, an evaporator with a few tubes plugged after a freeze, low chilled water flow from a strainer or valve left half closed, a compressor with worn unloading components, and controls reset to factory values during a board replacement. Load growth is the other answer: a lab fit-out, a new production line or denser server racks can outgrow a machine that was right when it was installed. Paul Industries runs a capacity check at measured flow and temperature before any repair is priced, so the owner knows whether the fix is a repair, a retune or added capacity.

Which New Hampshire buildings depend on their chillers all year?

New Hampshire buildings that depend on chillers all year include hospitals, biologics and pharmaceutical plants, semiconductor and precision manufacturers, university research buildings, data rooms, ice rinks and food and beverage plants. The table below sets out how a repair is planned in each.

Year-round chiller users in New Hampshire and how repairs are planned
Building typeExample of the marketWhy the load continues in winterHow the repair is planned
Hospitals and medical centersDartmouth Hitchcock Medical Center in Lebanon, the state’s only academic medical center, and the hospitals in Manchester, Concord, Nashua and on the SeacoastImaging, surgical suites, pharmacies and data roomsRemaining capacity confirmed against critical loads; temporary cooling where redundancy is thin
Biologics and pharmaceutical plantsLonza’s mammalian biologics site in Portsmouth, with bioreactors at 2,000, 6,000 and 20,000 liter scalesProcess and jacket cooling, cold rooms, controlled suitesRepairs timed to campaigns; change control records for validated systems
Semiconductor and precision makersThe BAE Systems Microelectronics Center in Nashua, a gallium arsenide and gallium nitride wafer foundry, and precision firms across the Merrimack ValleyProcess cooling water held to tight temperature limitsRedundant machines swapped under a written procedure; temperature stability verified before return
Universities and research buildingsCampus plants in Hanover, Durham and ManchesterResearch labs, freezers and data roomsOverhauls between terms; loop minimum capacity held
Ice rinksMunicipal, school and private rinks statewideIce is made from late summer through springRepairs in the off-season window; refrigerant and brine checks before the first flood
Food, beverage and brewingBreweries, dairies and confectionery plantsGlycol for fermentation, product cooling and cold storageRepairs between production runs; glycol strength tested at each visit

Industrial chiller maintenance at New Hampshire plants

Industrial chiller maintenance at New Hampshire plants follows the production calendar rather than the weather, because process machines carry loads through January. Paul Industries schedules oil and refrigerant analysis, vibration readings, tube inspection and control calibration into planned shutdowns, keeps spare parts lists matched to each machine, and provides the change and test records a validated plant needs to close the work. Process machines serving a single line are covered on the process chillers page.

HVAC chiller service at hospitals, schools and offices

HVAC chiller service at New Hampshire hospitals, schools and office buildings centers on the spring restart and the autumn shutdown, with repairs scheduled for the long cool season when the building can do without its machine. Hospitals are the exception, since their critical areas need cooling and dehumidification in every month.

Do New Hampshire pressure vessel rules reach a chiller?

RSA 157-A, the state’s boiler and pressure vessel statute, covers part of a chiller plant and exempts the rest through the list in section 157-A:6, and section 157-A:10 makes it unlawful to run a covered vessel with no valid inspection certificate. The program sits with the commissioner of labor, and the exemption list is specific enough that each vessel in the plant can be placed on one side of the line.

How RSA 157-A treats common chiller plant vessels
VesselExemption that can apply under RSA 157-A:6 IIIWhen the chapter applies
Refrigerant receiversGroup I refrigerant receivers under the ASHRAE classification are exemptReceivers for refrigerants outside Group I
Small vessels such as oil separators, filters and accumulatorsUp to 5 cubic feet at no more than 250 psig, or up to 1.5 cubic feet or 6 inches inside diameter at no more than 3,000 psigLarger vessels above those limits
Chilled water expansion and buffer tanksWater-containing vessels up to 125 psig working pressure, including those with an air cushionWorking pressure above 125 psig
Low-pressure vesselsVessels operating at 15 psig or lessHigher working pressures
Steam supply to absorption chillersNone for the boiler itselfBoilers feeding absorption machines carry their own certificate inspections

For a vessel inside the chapter, a vessel subject to internal corrosion receives a certificate inspection every two years under RSA 157-A:8. A welded repair to the pressure boundary of a nonexempt vessel is made under the National Board Inspection Code with the inspector consulted before work starts. Paul Industries lists each vessel’s exemption basis or certificate status in the repair file, and supplies replacement vessels built to ASME Section VIII; the pressure vessel fabrication in New Hampshire page covers that work, and steam-side work on absorption chillers connects to boiler repair in New Hampshire.

Federal refrigerant rules for New Hampshire chiller owners

Federal refrigerant rules set most of the paperwork on a New Hampshire chiller repair, and since January 1, 2026 two leak repair programs run side by side: the Section 608 rule for machines on ozone-depleting refrigerants such as R-22 and R-123, and the newer AIM Act rule for machines on HFCs such as R-134a and R-410A.

Under 40 CFR 82.157, appliances holding 50 pounds or more of an ozone-depleting refrigerant must have leaks repaired within 30 days once the annual leak rate passes 10 percent for comfort cooling, 20 percent for commercial refrigeration or 30 percent for industrial process refrigeration. Under 40 CFR 84.106, the same percentages apply to appliances holding 15 pounds or more of an HFC or certain substitutes, the leak rate has to be calculated every time refrigerant is added, and an industrial process shutdown extends the repair window to 120 days. Both rules require verification testing after the repair. On top of that, R-22 production and import ended in 2020 and HCFC production ends entirely in 2030, so older machines rely on reclaimed refrigerant, and new comfort cooling chillers installed since January 1, 2025 use refrigerants with a global warming potential below 700.

The smaller HFC threshold brings many scroll and small screw chillers into leak tracking for the first time. Paul Industries calculates and records the leak rate at each refrigerant addition, performs the verification tests and leaves the records with the owner’s equipment file.

Winter layup, freeze damage and spring restart

Winter layup protects a New Hampshire chiller that sits idle from November to April, and the most expensive repairs in the state follow a layup that failed. A frozen evaporator or condenser tube splits and lets water into the refrigerant circuit, which can mean a tube bundle repair, a full dehydration and oil change, and on a hermetic machine a motor rewind or replacement.

A sound layup drains the waterside completely or fills it with inhibited glycol, blows out low points and coils that will not drain by gravity, leaves oil heaters energized where the manufacturer calls for it, isolates and drains cooling tower basins and outdoor piping, and records refrigerant pressures so a winter leak shows up in spring. The restart reverses it with checks: a leak search before any refrigerant is added, flow proving on both water circuits, safety and sensor tests, and a run under real load before the first warm week. Paul Industries offers layup and restart as scheduled service, and repairs freeze damage when it happens, from plugging and retubing to compressor and motor work.

Air-cooled chillers under New Hampshire snow and ice

Air-cooled chillers on New Hampshire roofs and pads take damage that machines in milder states rarely see: snow drifting into condenser coils, ice building on fins during freezing rain, plow damage at ground level and roof leaks around curbs that have been loaded by snow for months. A machine that runs in winter for a data room or a lab also needs its fans, head pressure controls and crankcase heaters working at temperatures well below zero.

Repairs on these units start with the coil: straightening or replacing damaged fin sections, repairing leaks at tube bends cracked by ice or vibration, and replacing fan motors and blades. Raising a pad unit on taller rails, adding snow hoods or wind baffles, and relocating it away from roof valleys and drift zones prevents the same damage next winter. Paul Industries also checks the glycol concentration on air-cooled machines serving outdoor coils, since a weak mix that survived a mild December can freeze in a February cold snap.

How to maintain a chiller system through a New Hampshire year

How to maintain a chiller system in New Hampshire comes down to a calendar built around the restart, the summer peak, the shutdown and, for year-round machines, the cold condenser water months. The schedule below is a starting point that Paul Industries adjusts to each machine’s duty, age and manufacturer requirements, in line with ASHRAE/ACCA 180 practice.

A New Hampshire chiller maintenance calendar
PeriodSummer-only comfort machinesYear-round process, hospital and data room machines
March to AprilLeak search, refill or glycol check, flow proving, safeties, oil heaters, controls backupOil and refrigerant analysis, vibration readings, condenser tube inspection before the warm months
May to JuneStart under load, condenser tube cleaning, tower startup and water treatmentTower readiness, head pressure controls set for summer, capacity check
July to AugustOperating logs reviewed against design, leak rate records keptSame, plus redundancy confirmed before any planned outage
September to OctoberShutdown, drain or glycol fill, tower basin and piping drainedOverhaul window opens; staged repairs one machine at a time
November to FebruaryPressure readings on the idle machine to catch winter leaksHead pressure and freeze protection checks, eddy current testing on a set interval

How often should chiller tubes be cleaned? Condenser tubes on open tower systems are typically cleaned once a year, before the cooling season or during the annual shutdown, and more often where water treatment is weak; evaporator tubes on closed loops need it far less often. Eddy current testing, commonly on a three to five year cycle, shows whether the bundle is wearing and how fast.

Repair or replace at New Hampshire power prices

New Hampshire power prices weigh heavily in the repair or replace decision: in 2025 commercial customers paid an average of 20.11 cents per kilowatt-hour and industrial customers 16.82, against national averages of 13.37 and 8.51 (EIA). A replacement that saves 0.25 kilowatts per ton on a 400 ton comfort machine running 1,500 equivalent full-load hours saves about 150,000 kilowatt-hours, or roughly $30,000 a year at the commercial rate; the same improvement on a process machine running 6,000 hours saves about $100,000 a year at the industrial rate.

Those figures are examples, and the real calculation uses the owner’s tonnage, run hours and tariff. The other factors are the refrigerant, the condition of the compressor and tubes, the leak history under the federal rules, and whether the building can tolerate a replacement outage. NHSaves, the statewide efficiency program of the state’s electric utilities, offers chiller incentives, and its 2026 chiller application must be approved before the equipment is bought or installed. Paul Industries prepares the equipment data for that application and prices repair and replacement side by side.

Can chillers provide heating? Heat recovery and heat pump chillers can, by moving heat from the chilled water loop into a heating hot water loop, and in New Hampshire that option deserves a look whenever a hospital, lab or plant has simultaneous cooling and heating loads in winter.

Who repairs chillers in New Hampshire?

Paul Industries repairs chillers in New Hampshire, providing chiller service and repair for centrifugal, screw, scroll, absorption and process machines at hospitals, plants, campuses, rinks and data rooms. Its headquarters are at 256 Shore Drive in Kilmarnock, Virginia; the company was formerly based in northern New Jersey and then Pennsylvania, and it repairs chillers throughout New Hampshire, the rest of New England and all 50 states.

Who services chillers well is a question of method as much as hands: capacity checks before repairs are priced, leak rate records kept to the 2026 rule, layup and restart done as a scheduled job, and repairs that cover the condenser water, pumps and piping around the machine. Who installs chillers when repair is no longer the right answer is the same firm under the same contract: Paul Industries supplies and installs replacement machines, including rigging, piping, controls and startup. Related work in the state includes data center cooling systems in New Hampshire, process piping in New Hampshire and industrial welding in New Hampshire. The same chiller work is described for chiller repair in Massachusetts and Connecticut chiller repair, and for the company’s headquarters state on chiller repair in Virginia.

What does chiller repair cost in New Hampshire?

Chiller repair cost in New Hampshire depends on the fault, the machine type and size, the refrigerant, parts lead times and whether the work must happen during a cooling season or can wait for the long cool months. A sensor or control repair is a small job; a compressor rebuild, a retube or freeze damage on a large centrifugal is a major one, and the price follows the scope.

How much does it cost to replace a chiller? A replacement is priced on tonnage, refrigerant, rigging access, electrical and piping changes, controls integration, removal and refrigerant recovery from the old machine, and any temporary cooling. Paul Industries offers a budget range from comparable scope once the machine and site are known, and a firm price after a survey. A repair is priced fastest from the nameplate data, the trip and alarm record, a week of logged pressures and temperatures, and the most recent service visit notes.

Chiller repair and service from Paul Industries across New Hampshire

Paul Industries delivers an industrial chiller repair service and commercial chiller repair across New Hampshire: diagnostics, leak repair with federal records, compressor and motor work, tube cleaning and testing, freeze damage repair, layup and restart, overhauls, and replacement with new machines supplied and installed. Each repair file lists the pressure vessel status under RSA 157-A and the refrigerant records under federal rules, so the owner has one complete record. The state’s industries are described on the New Hampshire page and the region on New England. To schedule a repair, a layup program or a replacement study, request a quote or call 201-450-8280.

Standards referenced: EPA Emissions Reduction and Reclamation rule, 40 CFR 84.106 · Clean Air Act Section 608, 40 CFR Part 82 Subpart F · EPA Technology Transitions rule (40 CFR Part 84) · New Hampshire RSA 157-A (boilers and pressure vessels) · New Hampshire State Building Code, RSA 155-A (2024 International Mechanical Code) · ASHRAE 15 · ASHRAE/ACCA 180 · ASME Section VIII

Frequently asked questions

Who handles chiller repair for Manchester hospitals and Millyard buildings?

Paul Industries repairs chillers for Manchester hospitals, offices and the converted mill buildings of the Millyard, where shared central plants often serve labs, offices and data rooms from the same loop. Repairs are staged so the remaining machines carry critical loads, and work inside occupied buildings follows the facility’s outage procedures. Call 201-450-8280 or request a quote.

Does Paul Industries repair process chillers at fabs and precision plants in Nashua and Hudson?

Yes. Paul Industries repairs process chillers and cooling water systems for semiconductor, optics and precision manufacturers in Nashua, Hudson, Merrimack and Salem, where tool cooling water is held to tight temperature limits. Redundant machines are swapped under a written procedure, and temperature stability is verified at the tools before the repaired chiller returns to service.

Who repairs chillers at Seacoast biotech and food plants in Portsmouth, Dover and Stratham?

Paul Industries repairs chillers at biotech, food and manufacturing plants in Portsmouth, the Pease Tradeport, Dover, Rochester and Stratham. For validated biologics suites, repairs come with change control and test records; for food plants, glycol strength and heat exchanger condition are checked at the same visit. Salt air on the coast also calls for coil and enclosure inspection on air-cooled machines.

Does Paul Industries service chillers for campuses and hospitals in Lebanon, Hanover and Concord?

Paul Industries services and repairs chillers at hospital and campus central plants in Lebanon, Hanover, Concord and Keene, including research buildings that need cooling all winter. Overhauls are scheduled between academic terms or in the cool months, and the plan confirms that the remaining machines, pumps and towers carry the loop’s minimum load before any machine is opened.

Who repairs ice rink refrigeration chillers in the Lakes Region and the North Country?

Paul Industries repairs rink chillers and refrigeration plants for municipal, school and private ice rinks in Laconia, the Lakes Region, Berlin and across the North Country. Major repairs fit the off-season between spring and the late summer flood, with refrigerant, brine or glycol and pumps checked before ice making starts. Receivers outside the RSA 157-A Group I exemption are kept on their certificate schedule.

Who installs chillers in New Hampshire when a repair is no longer worth it?

Paul Industries supplies and installs replacement chillers in New Hampshire, handling rigging, piping, electrical connections, controls integration, refrigerant recovery from the old machine and startup. Replacements are usually scheduled for the cool months, when comfort loads are low, and year-round sites get temporary cooling or staged changeovers. New comfort machines use refrigerants with a global warming potential below 700.

How long do industrial chillers last in New Hampshire plants?

Industrial chillers in New Hampshire last for decades when they are maintained, with large screw and centrifugal machines generally outliving small scroll units. Life depends more on maintenance, water treatment and freeze protection than on the calendar, and a machine that froze once or ran with fouled tubes for several seasons ages faster. Overhauls and retubing extend life when the compressor and shell are sound.

Does a chiller refrigerant receiver need a New Hampshire inspection certificate?

It depends on the refrigerant and size. RSA 157-A:6 exempts Group I refrigerant receivers under the ASHRAE classification, and also exempts small vessels holding no more than 5 cubic feet at up to 250 psig. A receiver outside those exemptions needs the certificate inspections RSA 157-A requires, and operating it without a valid certificate is unlawful under RSA 157-A:10.

What leak records does the 2026 EPA rule require for a New Hampshire chiller?

For a chiller holding 15 pounds or more of an HFC, the owner must calculate the leak rate every time refrigerant is added, repair leaks within 30 days once the rate passes 10 percent for comfort cooling or 30 percent for industrial process machines, and keep verification test results. Machines on R-22 or R-123 with 50 pounds or more follow the parallel Section 608 rule.

Can an R-123 chiller in a New Hampshire building still be repaired?

Yes. Existing R-123 centrifugal chillers can be repaired and serviced, using reclaimed and previously produced refrigerant after HCFC production ends in 2030. Keeping the machine tight and the purge unit working protects a refrigerant supply that will only shrink. Paul Industries prices the repair and a replacement or retrofit path together, so the owner can plan the change before a major failure forces it.

Should a New Hampshire comfort chiller be drained every winter?

A comfort chiller that sits idle through a New Hampshire winter should either be drained completely, with low points and coils blown out, or filled with inhibited glycol, because Concord’s average January low is about 13 degrees Fahrenheit. Machines indoors in heated rooms still have outdoor towers and piping to protect. Freeze damage to tubes is one of the costliest chiller repairs.

Why does a year-round chiller trip on low pressure in a New Hampshire January?

Cold condenser water is the usual cause. When tower water returns at very low temperatures, condensing pressure falls, oil and refrigerant stop moving properly and the machine trips on low pressure or low oil differential. Head pressure control, a tower bypass valve, variable speed tower fans and correct minimum flow settings keep the condenser in range. Paul Industries checks those controls before the first cold snap.

How often should chiller tubes be cleaned at a New Hampshire plant?

Condenser tubes on open cooling tower systems are typically cleaned once a year, and plants with heavy process loads or weak water treatment clean more often. A rising condenser approach temperature is the signal. Evaporator tubes on closed loops need cleaning far less often. Eddy current testing every three to five years shows tube wall loss and tells the plant how many tubes are near failure.

Can NHSaves help pay for a replacement chiller in New Hampshire?

NHSaves, run by the state’s electric utilities, offers incentives for efficient chillers, including a custom chiller pathway. The 2026 chiller application must be completed and the incentive approved before the equipment is purchased or installed, so the application belongs early in the replacement schedule. Paul Industries prepares the efficiency and equipment data the application asks for.

Can chillers provide heating for a New Hampshire hospital or lab?

Heat recovery and heat pump chillers can. They take heat from the chilled water loop, which in winter carries heat from imaging rooms, labs, data rooms and process equipment, and deliver it to the heating hot water loop at useful temperatures. Where a building has both loads at once, the recovered heat displaces boiler fuel. Paul Industries evaluates the load profile before recommending one.

What does chiller repair cost in New Hampshire for a centrifugal machine?

Cost follows the fault: control and sensor repairs are modest, leak repairs depend on access and refrigerant price, and compressor rebuilds, retubes or freeze damage on a large centrifugal are major jobs priced on parts, rigging and hours. Paul Industries diagnoses first, then prices parts, refrigerant and labor separately, with a budget range for larger work before the machine is opened.

What does chiller service from Paul Industries include for a New Hampshire facility?

A Paul Industries program is built around the New Hampshire calendar: spring restart, summer log reviews, autumn layup for idle machines and cold-weather checks for year-round ones. Each visit adds to a running file of leak rate calculations, oil and refrigerant results, vibration trends and tube condition, and the towers, pumps and treatment program that feed the machines are added to the same schedule when the owner wants one file for the whole plant.

What should a New Hampshire facility send to get a chiller repair priced?

The most useful package is a nameplate photo, the refrigerant and its charge, a list of recent trips and alarms, a week or two of logged readings, the last service visit notes, the refrigerant addition log and a note on how the machine spent last winter, drained, glycol-filled or running. Photos of any visible damage help too. Call 201-450-8280 or request a quote.

Have a chiller to repair somewhere in New Hampshire?

Send a nameplate photo, the refrigerant, recent trips and alarms, and how the machine spent last winter. Call 201-450-8280 or request a quote.